Performance evaluation of quail closed-house system in Institute of Poultry Technology, Malaysia
2015
Nurul Aini M. Y. | Nurshuhada S. | Irdayu H.
Quail closed-house system is a house that support quails’ optimumrequirements as far as temperature, relative humidity, ventilation and light are concerned. One of the four units of quail closed-house systems at the Institute of Poultry Technology, Malacca was used in this study. The objective of this project was to evaluate the performance of the quail closed-house system by comparing the condition of the house under current management condition and after the Standard Operating Procedure determined by DVS was adhered. Thehouse performance was evaluated by observing its ability to achieve an optimum temperature range of 20°C to 27°C with a relative humidity between 60% to 80% as perfect surroundings for quails. At the end of the experiments, the results showed a decline in internal temperature at almost 3°C and increasing in a relative humidity of 10% after all the specifications and procedures were followed.
اظهر المزيد [+] اقل [-]الكلمات المفتاحية الخاصة بالمكنز الزراعي (أجروفوك)
المعلومات البيبليوغرافية
تم تزويد هذا السجل من قبل Universiti Putra Malaysia