Determination of the insertion position of implants for the cross-pin fixation of distal femoral physis fractures
2021
The cross-pin technique for the treatment of distal femoral physis fractures (specifically, Salter-Harris Type I fractures) was investigated using femurs collected from beagle cadavers. The pin was inserted from the medial surface of the femur at an inclination of approximately 30 to 45° relative to the long axis of the femur in the anteroposterior direction; the pin exit was set proximal to the origin of the long digital extensor tendon. Digital and radiographic images of the femur in the anteroposterior and lateral directions were obtained. In both types of images, the insertion angle of the pin relative to the long axis was measured. Results suggest that when inserting a pin proximal to the fracture line, the ideal position can be achieved by inclining the pin approximately 20° cranially relative to the long axis of the lateral direction of the femur, in addition to the previously described criteria.