Experimental study of hydraulic losses in linear and nonlinear weirs: A comparative analysis
2024
Reza Ghasemi Ghasemvand | Mohammad Heidarnejad | Alireza Masjedi | Amin Bordbar
With increased length of the crest in a certain width range, the labyrinth weirs increase the discharge capacity. In this study, a laboratory flume was used with a length of 8 m and a width and height of 0.6 m, in which the hydraulic loss of linear/non-linear, labyrinth, triangular, and trapezoidal weirs were investigated. Dimensional analysis using the Buckingham methodology showed that the discharge coefficient (Cd) is a function of parameters such as hydraulic head ratio (Ht/P), weir shape factor (Sf), and hydraulic loss ratio (Hf/P). The results showed that the ATRL weir has a lower discharge coefficient than the ALR by 44% and ATPL a lower discharge coefficient than ALR by 50%. The ATRL weir has a higher hydraulic loss than ALR by 2300% and a higher hydraulic loss than ATPL by 2000%. The TRL weir has a higher hydraulic loss than LR by 4900% and a higher hydraulic loss than TPL by 5700%. The TRL weir has a lower discharge coefficient than LR by 41% and TPL by 43%. The best correlation with the Cubic statistical model was obtained in the TPL weir in terms of discharge coefficient and in the ALR weir in terms of hydraulic loss.
اظهر المزيد [+] اقل [-]الكلمات المفتاحية الخاصة بالمكنز الزراعي (أجروفوك)
المعلومات البيبليوغرافية
تم تزويد هذا السجل من قبل Directory of Open Access Journals