Evaluation of the diagnostic yield of dental radiography and cone-beam computed tomography for the identification of dental disorders in small to medium-sized brachycephalic dogs
2018
Doring, Sophie | Arzi, Boaz | Hatcher, David C. | Kass, Philip H. | Verstraete, Frank J. M.
OBJECTIVE To evaluate the diagnostic yield of dental radiography (Rad method) and cone-beam CT (CBCT) methods for the identification of 31 predefined dental disorders in brachycephalic dogs. ANIMALS 19 client-owned brachycephalic dogs admitted for evaluation and treatment of dental disease. PROCEDURES 31 predefined dental disorders were evaluated separately and scored by use of dental radiography and 3 CBCT software modules (serial CBCT slices and custom cross sections, tridimensional rendering, and reconstructed panoramic views). A qualitative scoring system was used. Dental disorders were grouped into 10 categories for statistical analysis. Point of reference for presence or absence of a dental disorder was determined as the method that could be used to clearly identify the disorder as being present. Accuracy, sensitivity, specificity, and positive and negative predictive values were calculated with the McNemar χ2 test of marginal homogeneity of paired data. RESULTS When all 3 CBCT methods were used in combination, the diagnostic yield of CBCT was significantly higher than that of dental radiography for 4 of 10 categories (abnormal eruption, abnormally shaped roots, periodontitis, and tooth resorption) and higher, although not significantly so, for all categories, except for 1 (loss of tooth integrity). CONCLUSIONS AND CLINICAL RELEVANCE CBCT provided more detailed information than did dental radiography. Therefore, CBCT would be better suited for use in diagnosing dental disorders in brachycephalic dogs.
اظهر المزيد [+] اقل [-]Quantification of right ventricular volume measured by use of real-time three-dimensional echocardiography and electrocardiography-gated 64-slice multidetector computed tomography in healthy dogs
2018
LeBlanc, Nicole L. | Scollan, Katherine F.
OBJECTIVE To evaluate accuracy of quantification of right ventricle volume (RVV) by use of 3-D echocardiography (3DE) and ECG-gated multidetector CT (MDCT). ANIMALS 6 healthy hound-cross dogs. PROCEDURES ECG-gated MDCT and complete 3DE examinations were performed on each dog. Right ventricular end-diastolic volumes (EDVs), end-systolic volumes (ESVs), stroke volume (SV), and ejection fraction (EF) were measured for 3DE and MDCT data sets by use of software specific for RVV quantification. Correlation and level of agreement between methods were determined. Intraobserver and interobserver variability were assessed for 3DE. RESULTS No significant differences were detected between SV and EF obtained with MDCT and 3DE. Significant differences were detected between right ventricular EDV and ESV obtained with MDCT and 3DE. No significant difference in heart rate was detected between methods. The correlation between MDCT and 3DE was very good (r = 0.87) for EDV and ESV, moderate (r = 0.60) for EF, and poor (r = 0.31) for SV. Bland-Altman analysis revealed a systematic underestimation of RVV derived by use of 3DE, compared with the RVV derived by use of MDCT (mean bias, 15 and 10.3 mL for EDV and ESV, respectively). Intraobserver (EDV, 12%; ESV, 18%) and interobserver (EDV, 14%; ESV, 11%) variability were acceptable for 3DE. CONCLUSIONS AND CLINICAL RELEVANCE There was substantial variance for RVV measured by use of 3DE in healthy dogs and a significant underestimation of volumes, compared with results for MDCT, despite the fact there were no significant differences in SV and EF.
اظهر المزيد [+] اقل [-]Three-dimensional assessment of the influence of juvenile pubic symphysiodesis on the pelvic geometry of dogs
2018
Dunlap, Anna E. | Mathews, Kyle G. | Walters, Bethany L. | Bruner, Kent A. | Ru, Hongyu | Marcellin-Little, Denis J.
OBJECTIVE To evaluate the 3-D geometry of canine pelves and to characterize the long-term effects of juvenile pubic symphysiodesis (JPS) on pelvic geometry by comparing the pelvic configuration between littermates that did and did not undergo the procedure. ANIMALS 24 Labrador Retriever, Golden Retriever, or Labrador Retriever–Golden Retriever crossbred service dogs from 13 litters. PROCEDURES At 16 weeks old, puppies with a hip joint distraction index ≥ 0.5 were randomly assigned to undergo thermal JPS (n = 9), mechanical JPS (7), or a sham (control) surgical procedure (8). Ten years later, each dog underwent a CT scan of the pelvic region. Modeling software was used to create 3-D reconstructions from the CT scans, and various pelvic measurements were made and compared among the 3 treatments. RESULTS Compared with the control treatment, thermal and mechanical JPS increased the hemipelvis acetabular angle by 4°, the acetabular angle of lateral opening by 5°, and the orientation of the medial acetabular wall in a transverse plane by 6°, which indicated that JPS increased dorsal femoral head coverage by the acetabulum. Both JPS procedures decreased the pelvic canal area by approximately 20% and acetabular inclination by 6° but did not alter acetabular retroversion. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that thermal and mechanical JPS were equally effective in altering the 3-D pelvic geometry of dogs. These findings may help guide future studies of alternatives for optimizing canine pelvic anatomy to minimize the risk of hip dysplasia and associated osteoarthritis.
اظهر المزيد [+] اقل [-]Evaluation of the diagnostic yield of dental radiography and cone-beam computed tomography for the identification of anatomic landmarks in small to medium-sized brachycephalic dogs
2018
Doring, Sophie | Arzi, Boaz | Barich, Catherine R. | Hatcher, David C. | Kass, Philip H. | Verstraete, Frank J. M.
OBJECTIVE To evaluate the diagnostic yield of dental radiography (Rad method) and 3 cone-beam CT (CBCT) methods for the identification of predefined anatomic landmarks in brachycephalic dogs. ANIMALS 19 client-owned brachycephalic dogs admitted for evaluation and treatment of dental disease. PROCEDURES 26 predefined anatomic landmarks were evaluated separately by use of the RAD method and 3 CBCT software modules (serial CBCT slices and custom cross sections, tridimensional rendering, and reconstructed panoramic views). A semiquantitative scoring system was used, and mean scores were calculated for each anatomic landmark and imaging method. The Friedman test was used to evaluate values for significant differences in diagnostic yield. For values that were significant, the Wilcoxon signed rank test was used with the Bonferroni-Holm multiple comparison adjustment to determine significant differences among each of the 6 possible pairs of diagnostic methods. RESULTS Differences of diagnostic yield among the Rad and 3 CBCT methods were significant for 19 of 26 anatomic landmarks. For these landmarks, Rad scores were significantly higher than scores for reconstructed panoramic views for 4 of 19 anatomic landmarks, but Rad scores were significantly lower than scores for reconstructed panoramic views for 8 anatomic landmarks, tridimensional rendering for 18 anatomic landmarks, and serial CBCT slices and custom cross sections for all 19 anatomic landmarks. CONCLUSIONS AND CLINICAL RELEVANCE CBCT methods were better suited than dental radiography for the identification of anatomic landmarks in brachycephalic dogs. Results of this study can serve as a basis for CBCT evaluation of dental disorders in brachycephalic dogs.
اظهر المزيد [+] اقل [-]Blink patterns and kinematics of eyelid motion in ophthalmologically normal horses
2018
Best, Lori J. | Alexiades, Vasilios | Hendrix, Diane V. H. | Chen, Thomas | Ward, Daniel A.
OBJECTIVE To describe qualitative blinking patterns and determine quantitative kinematic variables of eyelid motion in ophthalmologically normal horses. ANIMALS 10 adult mares. PROCEDURES High-resolution videography was used to film blinking behavior. Videotapes were analyzed for mean blink rate, number of complete versus incomplete blinks, number of unilateral versus bilateral blinks, and subjective descriptions of blinking patterns. One complete blink for each horse was analyzed with image-analysis software to determine the area of corneal coverage as a function of time during the blink and to calculate eyelid velocity and acceleration during the blink. RESULTS Mean ± SD blink rate was 18.9 ± 5.5 blinks/min. Blinks were categorized as minimal incomplete (29.7 ± 15.6%), moderate incomplete (33.5 ± 5.9%), complete (30.8 ± 13.1%), and complete squeeze (6.0 ± 2.8%); 22.6 ± 9.0% of the blinks were unilateral, and 77.3 ± 9.1% were bilateral. Mean area of exposed cornea at blink initiation was 5.89 ± 1.02 cm2. Mean blink duration was 0.478 seconds. Eyelid closure was approximately twice as rapid as eyelid opening (0.162 and 0.316 seconds, respectively). Deduced maximum velocity of eyelid closure and opening was −16.5 and 7.40 cm/s, respectively. Deduced maximum acceleration of eyelid closure and opening was −406.0 and −49.7 cm/s2, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Kinematic variables of ophthalmologically normal horses were similar to values reported for humans. Horses had a greater percentage of complete squeeze blinks, which could increase tear film stability. Blinking kinematics can be assessed as potential causes of idiopathic keratopathies in horses.
اظهر المزيد [+] اقل [-]