خيارات البحث
النتائج 1 - 4 من 4
Comparison of electrocardiographic parameters in dogs with different stages of myxomatous mitral valve disease
2021
Na, Yejin | Lee, Dohee | Yun, Taesik | Koi, Yoonhoi | Chae, Yeon | Kim, Hakhyun | Yang, Mhan-Pyo | Kang, Byeong-Teck
This study evaluated changes in electrocardiographic (ECG) parameters according to the stage of myxomatous mitral valve disease (MMVD) in dogs, as well as the utility of ECG parameters as prognostic indicators for congestive heart failure (CHF). Medical records of dogs with MMVD were retrospectively searched. Dogs with MMVD (N = 101) were classified into stages B [B1 (n = 52) and B2 (n = 23)] and C (n = 26) according to the American College of Veterinary Internal Medicine guidelines. Baseline variables were collected; these included signalment, radiographic, echocardiographic, and ECG parameters. Corrected QT intervals (QTc) were calculated using the logarithmic (QTc1) and Fridericia (QTc2) formulas. The P wave duration, QTc1, and QTc2 were significantly longer in stage C than in stage B. The P wave duration cutoff of 43.5 ms had a diagnostic accuracy of 65% for differentiating CHF, with a sensitivity of 63% and a specificity of 90%. A cutoff value of 307.8 ms for QTc1 yielded a sensitivity of 62%, a specificity of 76%, and a diagnostic accuracy of 78%, and a cutoff value of 239.2 ms for QTc2 yielded a sensitivity of 62%, a specificity of 83%, and a diagnostic accuracy of 77% for diagnosing CHF. Therefore, prolonged P wave and QTc in dogs with MMVD may facilitate the prediction of CHF. Electrocardiography could provide clinicians with a readily available and cost-effective screening tool for predicting CHF, if the usefulness of ECG parameters can be verified.
اظهر المزيد [+] اقل [-]Impact of selected individual dog traits on echocardiographic parameters obtained in 1-dimensional (M-mode) and 2-dimensional (2D) imaging
2021
Szpinda, Oktawia | Parzeniecka-Jaworska, Marta | Jank, Michal | Garncarz, Magdalena | Czopowicz, Michal
The popularity and availability of echocardiography in veterinary practice for companion animals have substantially increased in recent years. The results obtained during the procedure are compared to reference values established for the general dog population or to standards developed for a specific dog breed. The aim of this study was to determine whether individual dog traits, such as body weight, chest structure, and level of physical activity and performance, affect the reference values for echocardiographic parameters. Published reference values for echocardiographic examination parameters for 32 dog breeds were analyzed and the relationship between individual echocardiographic parameters and body weight, chest structure, and level of physical activity and performance was then statistically analyzed. It was found that echocardiographic parameters are affected by the dog's weight and physical activity. There was no significant relationship between heart size and chest structure. The great variety of dog breeds means that echocardiographic findings should be individually interpreted rather than establishing reference ranges for each breed in population studies. This will allow for a more accurate interpretation of the results obtained in the echocardiographic examination and consequently lead to earlier diagnosis of changes in myocardial morphology.
اظهر المزيد [+] اقل [-]Repeatability, reproducibility, and reference intervals for indices of right atrial longitudinal strain derived from speckle-tracking echocardiography in healthy dogs
2021
Morita, Tomoya | Nakamura, Kensuke | Osuga, Tatsuyuki | Takiguchi, Mitsuyoshi
OBJECTIVE To determine repeatability, reproducibility, and reference intervals of indices of right atrial longitudinal strain (RALS) derived from speckle-tracking echocardiography (STE) in dogs without heart disease. ANIMALS 110 client-owned dogs and 10 laboratory Beagles. PROCEDURES To determine intraobserver within-day (repeatability) and interobserver (reproducibility) coefficients of variation, RALS during ventricular systole (ϵS), ventricular early diastole (ϵE), and atrial systole (ϵA), as derived with STE, were obtained by 2 investigators for 5 randomly selected client-owned dogs and analyzed by linear regression. Reference intervals were estimated from the results of all dogs. Correlations between RALS indices (ϵS, ϵE, and ϵA) and sex, age, body weight, heart rate, and blood pressure were determined. RESULTS RALS derived from STE showed good intraobserver within-day repeatability and interobserver reproducibility, with coefficients of variation of < 20%. Both ϵS and ϵE were significantly negatively correlated with age, but ϵA was not correlated with age. Indices were not correlated with sex, body weight, or blood pressure. CONCLUSIONS AND CLINICAL RELEVANCE RALS indices derived from STE were repeatable and reproducible and were affected by the age of dogs without heart disease. Age should be considered in the interpretation of RALS indices in clinical settings. Further studies are needed to apply RALS indices for assessing dogs with heart disease.
اظهر المزيد [+] اقل [-]Intravenous administration of allogeneic Wharton jelly-derived mesenchymal stem cells for treatment of dogs with congestive heart failure secondary to myxomatous mitral valve disease
2021
Yang, Vicky K. | Meola, Dawn M. | Davis, Airiel | Barton, Bruce | Hoffman, Andrew M.
OBJECTIVE To evaluate whether mesenchymal stem cells (MSCs) can be safely administered IV to dogs with congestive heart failure (CHF) secondary to myxomatous mitral valve disease (MMVD) to improve cardiac function and prolong survival time. ANIMALS 10 client-owned dogs with CHF secondary to MMVD. PROCEDURES Dogs with an initial episode of CHF secondary to MMVD were enrolled in a double-blind, placebo-controlled clinical trial. Five dogs in the MSC group received allogeneic Wharton jelly-derived MSCs (2 × 106 cells/kg, IV), and 5 dogs in the placebo group received a 1% solution of autologous serum (IV) for 3 injections 3 weeks apart. Cell-release criteria included trilineage differentiation, expression of CD44 and CD90 and not CD34 and major histocompatability complex class II, normal karyotype, and absence of contamination by pathogenic microorganisms. Patients were followed for 6 months or until death or euthanasia. Echocardiographic data, ECG findings, serum cardiac biomarker concentrations, CBC, and serum biochemical analysis results were obtained prior to and 4 hours after the first injection and every 3 months after the final injection. RESULTS Lymphocyte and eosinophil counts decreased significantly 4 hours after injection, and monocytes decreased significantly only in dogs that received an MSC injection. No significant differences were seen in the echocardiographic variables, ECG results, serum cardiac biomarker concentrations, survival time, and time to first diuretic drug dosage escalation between the 2 groups. CONCLUSIONS AND CLINICAL RELEVANCE This study showed that MSCs can be easily collected from canine Wharton jelly as an allogeneic source of MSCs and can be safely delivered IV to dogs with CHF secondary to MMVD.
اظهر المزيد [+] اقل [-]