خيارات البحث
النتائج 1 - 2 من 2
Occurrence of tetracyclines, sulphonamides and quinolones residues in chicken meat sample from selected chicken slaughterhouses in Peninsular Malaysia
2018
Chai, L. C. | Nor Ainy M. | Marni S. | Marzura M. R. | Ungku Fatimah U. Z. A. | Khairunnisak M.
The occurrence of veterinary drug residues in chicken meat originating from 320 small and medium scale chicken slaughterhouses in Peninsular Malaysia was determined. 637 chicken meat samples were examined for tetracycline (TCs), sulphonamide (SAs) and quinolone residues using a microbiological inhibition test and was further confirmed using liquid chromatography mass spectrometry (LCMS/MS). The presence of TC residues were confirmed in 10 (1.6%) samples, and 1 (0.2%)sample was confirmed in compliance to the established maximum residue limit (MRL) for residues of quinolone. A total of 6 (0.9%) samples were above the MRL for TC. The samples were from Pulau Pinang, Terengganu and Kelantan. Among those tested in compliance, the main analytes found for TC and quinolone werechlortetracyclines (CTC), enrofloxacin and mixture of chlortetracycline (CTC) and oxytetracycline (OTC). No samples were found to contain sulfonamides residues.
اظهر المزيد [+] اقل [-]Monitoring of melamine in milk and feed using ELISA and LCMS/MS screening methods
2011
Suhaimi D. | Lily Suhaida M. S. | Ismail M. | Wan Syahidah H.
A monitoring program for melamine in milk and feed was conducted in response to global melamine alertness in the year 2008. Two screening methods were adopted i.e., a liquid chromatography triple quadrupole tandem mass spectrometry (LC-MS/MS) and enzyme-linked
immunosorbent assay (ELISA). The liquid chromatography method developed by several international research centers was adapted. This method consisted of an initial extraction with 10%trichloroacetic acid (TCA) for milk samples or 60% methanol/water for feed samples, followed by a series of centrifugation, dilution and filtration steps. Melamine was analysed in the chromatographic program using a zwitterionic HILIC LC column. Electrospray ionisation in positive ion mode was used. The quantity of melamine
present was determined with a calibration curve consisting of sample extracts from milk or feed fortified from 25 to 50 ppb that were taken through the extraction procedure. The ranges of recovery from
fortified raw milk samples (n=20) and feed samples (n=21) was 70–80% and 68%, respectively. The limit of detection was estimated at 10 ppb for both matrixes. Milk samples were found negative for melamine,
however 4.5% of feed samples were found to contain the compound at concentrations between 1 to 5 ppm.
اظهر المزيد [+] اقل [-]