Cleaning with a wet sterile gauze significantly reduces contamination of sutures, instruments, and surgical gloves in an ex-vivo pelvic flexure enterotomy model in horses
2017
Giusto, G. | Tramuta, C. | Caramello, V. | Comino, F. | Nebbia, P. | Robino, P. | Singer, E. | Grego, E. | Gandini, M.
The objective of this study was to investigate whether cleaning surgical materials used to close pelvic flexure enterotomies with a wet sterile gauze will reduce contamination and whether the use of a full thickness appositional suture pattern (F) or a partial thickness inverting (or Cushing) suture pattern (C) would make a difference in the level of contamination. Large colon specimens were assigned to group F or C and divided into subgroups N and G. In group G, a wet sterile gauze was passed over the suture material, another over the instruments, and another over the gloves. In group N, no treatment was applied. The bacterial concentration was measured by optical density (OD) at 24 h. The OD of subgroup CG was lower than that of subgroup CN (P = 0.019). The OD of subgroup FG was lower than that of subgroup FN (P = 0.02). The OD of subgroups CG, CN, FG, and FN was lower than that of the negative control (P < 0.003, P < 0.001, P < 0.001, and P < 0.00). The use of a sterile wet gauze significantly reduced contamination of suture materials. A partial thickness inverting suture pattern did not produce less contamination than a full thickness appositional suture pattern.
اظهر المزيد [+] اقل [-]In vitro mechanical evaluation of equine laryngeal tie-forward constructs prepared with different suture materials and placement patterns
2015
Santos, Marcos P. | Gutierrez-Nibeyro, Santiago D. | Horn, Gavin P. | Hicke, Joshua D. | Stewart, Matthew C. | Schaeffer, David J.
OBJECTIVE To compare the mechanical properties of laryngeal tie-forward (LTF) constructs prepared with different suture materials and suture placement patterns during single load to failure testing. SAMPLE Larynges harvested from 50 horse cadavers and 5 intact horse cadavers. PROCEDURES In vitro LTF constructs were created by a standard technique with polyester sutures, a standard technique with polyethylene sutures, a modified technique with metallic implants and polyester sutures, a modified technique with metallic implants and polyethylene sutures, or a modified tie-off technique with polyester sutures (10 of each type of construct). Mechanical properties including maximal load (N) at failure and failure mode were compared among constructs. Also, maximal loads at failure of the in vitro LTF constructs were compared with the loads exerted on the sutures tightened to achieve rostral laryngeal advancement in intact cadavers. RESULTS Constructs prepared by a standard technique with polyethylene sutures had a significantly higher pull out strength than those prepared by a modified technique with metallic implants and either polyester or polyethylene sutures. For constructs prepared by a standard technique with polyethylene sutures or similarly placed polyester sutures, maximal load at failure did not differ but the failure mode did differ significantly. The load to failure for all in vitro constructs was higher than the maximal load measured during a range of motion test in intact horse cadavers. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that LTF procedures can be performed in live horses with any of the suture materials and techniques tested.
اظهر المزيد [+] اقل [-]The treatment of lower extremity defects with severe proliferative tissue using an adjustable horizontal mattress suture in a Tosa dog
2014
Heo, S.Y., Chonbuk University, Jeonju, Republic of Korea | Kim, N.S., Chonbuk University, Jeonju, Republic of Korea
A 2-year-old male Tosa was admitted for treatment of a non-healing wound on the right forelimb. Skin tests were unremarkable; however, the lesion contained severe proliferative tissue. Surgical treatment was conducted due to the extensive skin defect and granulation tissue present. Following removal of the proliferative tissue, the wound was closed using the adjustable horizontal mattress suture method with multiple punctate relaxing incisions. The proliferative tissue healed completely after the surgical treatment. This technique can be considered an alternative treatment for the proliferative tissue when conditions require a skin graft or flap after surgical treatment.
اظهر المزيد [+] اقل [-]Mechanical properties of various suture materials and placement patterns tested with surrogate in vitro model constructs simulating laryngeal advancement tie-forward procedures in horses
2014
Santos, Marcos P. | Gutierrez-Nibeyro, Santiago D. | Horn, Gavin P. | Johnson, Amy J. | Stewart, Matthew C. | Schaeffer, David J.
Objective- To compare the mechanical properties of laryngeal tie-forward (LTF) surrogate constructs prepared with steel fixtures and No. 5 braided polyester or braided polyethylene by use of a standard or a modified suture placement technique. Sample- 32 LTF surrogate constructs. Procedures- Surrogate constructs were prepared with steel fixtures and sutures (polyester or polyethylene) by use of a standard or modified suture placement technique. Constructs underwent single-load-to-failure testing. Maximal load at failure, elongation at failure, stiffness, and suture breakage sites were compared among constructs prepared with polyester sutures by means of the standard (n = 10) or modified (10) technique and those prepared with polyethylene sutures with the standard (6) or modified (6) technique. Results- Polyethylene suture constructs had higher stiffness, higher load at failure, and lower elongation at failure than did polyester suture constructs. Constructs prepared with the modified technique had higher load at failure than did those prepared with the standard technique for both suture materials. All sutures broke at the knot in constructs prepared with the standard technique. Sutures broke at a location away from the knot in 13 of 16 constructs prepared with the modified technique (3 such constructs with polyethylene sutures broke at the knot). Conclusions and Clinical Relevance- Results suggested LTF surrogate constructs prepared with polyethylene sutures or the modified technique were stronger than those prepared with polyester sutures or the standard technique.
اظهر المزيد [+] اقل [-]In vitro evaluation of anatomic landmarks for the placement of suture to achieve effective arytenoid cartilage abduction by means of unilateral cricoarytenoid lateralization in dogs
2014
Objective- To evaluate anatomic landmarks to define the ideal suture placement location to achieve appropriate and consistent arytenoid cartilage abduction via unilateral cricoarytenoid lateralization (UCL) in dogs. Sample- 6 cadaveric canine larynges. Procedures- Laryngeal airway resistance (LAR) was determined for each specimen before (baseline) and after suture placements with the epiglottis open and closed. To achieve UCL, suture was placed through the cricoid cartilage just caudal to the cricoarytenoid articulation (suture placement position [SPP] 1), one-fourth of the distance caudally between the cricoarytenoid and cricothyroid articulations (SPP 2), and three-fourths of the distance caudally between the cricoarytenoid and cricothyroid articulations (SPP 3). The LAR was again calculated after tensioning of each suture separately. Results- With a closed epiglottis, median LAR was 30.0, 20.4, 11.4, and 3.3 cm H2O/L/s at baseline and SPPs 1, 2, and 3, respectively. After UCL at SPP 1, LAR with the epiglottis closed was not significantly different from that at baseline. With an open epiglottis, median LAR was 2.0, 0.4, 0.2, and 0.0 cm H(2)O/L/s at baseline and SPPs 1, 2, and 3, respectively. After UCL at SPPs 1, 2, or 3, LAR with an open epiglottis was significantly lower than that at baseline. Conclusions and Clinical Relevance- Results indicated that placement of suture through the cricoid cartilage at the caudal border of the cricoarytenoid articulation was appropriate to sufficiently reduce LAR without increasing the risk of aspiration pneumonia through overabduction of the arytenoid cartilage.
اظهر المزيد [+] اقل [-]A transducer for measuring force on surgical sutures
2010
The objective of this study was to validate, both in vitro and in an ex vivo model, a technique for the measurement of forces exerted on surgical sutures. For this purpose, a stainless steel E-type buckle force transducer was designed and constructed. A strain gauge was mounted on the central beam of the transducer to measure transducer deformation. The transducer was tested and calibrated on a single strand of surgical suture during cyclic loading. Further validation was performed using a previously published cadaveric model of laryngoplasty in the horse. Linear regression of transducer output with actual force during calibration tests resulted in mean R2 values of 1.00, 0.99, and 0.99 for rising slope, falling slope, and overall slope, respectively. The R2 was not less than 0.96 across an average of 75 cycles per test. The difference between rising slope and falling slope was 4%. Over 45 846 samples, the predicted force from transducer output showed a mean error of 4%. In vitro validation produced an adjusted R2 of 0.99 when the force on the suture was regressed against translaryngeal pressure in a mixed-effects model. E-type buckle force transducers showed a highly linear output over a physiological force range when applied to surgical suture in vitro and in an ex vivo model of laryngoplasty. With appropriate calibration and short-term in vivo implantation, these transducers may advance our knowledge of the mechanisms of success and failure of techniques, such as laryngoplasty, that use structural suture implants.
اظهر المزيد [+] اقل [-]Comparison of staple and suture techniques for end-to-end anastomosis of the small colon in horses
1988
Hanson, R.R. | Nixon, A.J. | Calderwood-Mays, M. | Gronwall, R. | Pendergast, J.F.
Two techniques for end-to-end anastomosis of the small colon were evaluated in each of 6 horses. A simple interrupted suture pattern that excluded the mucosa and was oversewn with an inverting suture was compared with a triangulated double-row pattern of stainless steel staples. Anastomotic sites were evaluated at 2 weeks, 2 months, and 6 months for extent of abdominal adhesions, lumen diameter at anastomotic sites, bursting pressures, and healing response. Clinical postoperative complications were not associated with either technique. At postmortem examination, there was extensive adhesion formation from the mesocolon to the stapled anastomotic site. The suture technique resulted in greater luminal diameters (P less than or equal to 0.05), with good apposition of the tissue layers. Staples were missing as early as 2 weeks after surgery, and their loss was associated with separation of the muscularis at later evaluation periods. Regardless of technique, all but one anastomotic segment burst away from the anastomotic site along the mesenteric taenial band. For the 12 anastomoses performed in normal horses, the suturing technique was better than the stapling technique because of significantly larger lumen diameters, better anastomotic healing, and minimal intra-abdominal adhesion formation.
اظهر المزيد [+] اقل [-]Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice
2016
Avoine, Xytilis | Lussier, Bertrand | Brailovski, Vladimir | Inaekyan, Karine | Beauchamp, Guy
The influence of the type of material used, knot configuration, and use of an additional throw on the tensile force at failure, the elongation, and the mode of failure of different configurations of linear sutures and knotted suture loops was evaluated in this in-vitro mechanical study. We hypothesized that all types of knots would significantly influence the initial force and elongation of suture materials and would influence the force and elongation at which the knotted loops break, but not their mode of failure. A total of 432 samples of 4 types of size 3-0 suture material (polydioxanone, polyglecaprone 25, polyglactin 910, and nylon), representing 9 configurations, were tested in a tensiometer. The configurations were 1 linear suture without a knot and the following loops: square (SQ) knot; surgeon's (SU) knot; granny (GR) knot; and sliding half-hitch (SHH) knot using either 4 and 5 or 3 and 4 throws, depending on the material. For polydioxanone, SQ and SU knots did not decrease the initial force at failure of the suture. Granny (GR) and SHH knots decreased the tensile force at failure and elongation by premature failure of the loop. For polyglecaprone 25, all knots decreased the initial force at failure of the suture, with SHH being weaker than the other knots. For coated polyglactin 910, all knots decreased the initial force at failure of the suture and slippage increased significantly compared with the other 3 sutures. The use of SQ knots with 3 throws did not result in a safe knot. For nylon, knots did not alter the original mechanics of the suture. In conclusion, all knots and types of suture material do not necessarily have the same effect on the initial tensile force at failure of suture materials.
اظهر المزيد [+] اقل [-]Effect of configuration on the biomechanical performance of three suture materials used in combination with a metallic bone anchor
2013
Wasik, Sonya M. | Voss, K (Katja) | Cross, Rod C.
Objective—To determine whether different suture configurations could improve the biomechanical performance of 3 suture materials used with bone anchors. Samples—3 suture materials (60-lb test nylon leader line, size 2 polyblend polyethylene composite suture, and 150-lb test ultrahigh–molecular weight spun polyethylene). Procedures—Each suture material was looped through the eyelet of a metallic bone anchor and constructs were evaluated by use of an acute uniaxial load. Three configurations were tested for each suture material: single stranded (SS), double stranded (DS), and single stranded plus plastic insert (SSP). Force at failure, extension at failure, force at 3 mm of extension, stiffness, and site of failure of the suture were recorded for each test. Results—For all sutures, the DS configuration was the stiffest and yielded significantly higher forces at failure and forces at 3 mm of extension. The SS configuration had the lowest forces at failure. The SSP configuration yielded greater forces at failure for all suture materials, compared with the SS configuration, with a comparable stiffness. All sutures failed at the eyelet in the SS and DS configurations. In the SSP configuration, 60-lb test nylon leader line and 150-lb test ultrahigh-molecular weight spun polyethylene failed at the eyelet less frequently than did the polyblend composite suture. Conclusions and Clinical Relevance—Among the tested constructs, a DS suture configuration used in combination with the metallic bone anchor gave the best biomechanical results for all suture materials. Considering that the SSP configuration yielded greater forces at failure, compared with the SS configuration, covering metallic edges in bone anchors with softer materials might protect sutures and result in increased forces at failure.
اظهر المزيد [+] اقل [-]Evaluation of a novel suture material for closure of intestinal anastomoses in canine cadavers
2012
Hansen, Lane A. | Monnet, Eric L.
Objective: To compare leakage and maximum intraluminal pressures for a novel suture material with pressures for comparable suture material when used in closure of intestinal anastomoses in canine cadavers. Sample: Healthy intestines from cadavers of dogs euthanized for reasons unrelated to the study. Procedures: 18 anastomoses were performed on intestinal sections within 72 hours after dogs were euthanized and intestinal samples collected. Anastomoses were performed with a simple continuous suture pattern. Leakage and maximum intraluminal pressures were measured and recorded for 6 control segments and 18 anastomosed sections. A barbed glycomer 631 suture (size 4–0 United States Pharmacopeia [USP]) was compared with glycomer 631 sutures (sizes 3–0 and 4–0 USP). Results for leakage and maximum intraluminal pressures were compared via an ANOVA. Results: The barbed glycomer 631 suture material leaked at a significantly higher pressure than did the comparable glycomer 631 suture materials. Maximum intraluminal pressures were not significantly different among the suture materials. Conclusions and Clinical Relevance: Barbed glycomer 631 4–0 USP suture material was as effective as glycomer 631 suture materials and may be a safe alternative for use in closure of enterectomies in dogs.