خيارات البحث
النتائج 41 - 50 من 129
An ultrasonographic off-set system for examination of equine tendons and ligaments
1991
Wood, A.K.W. | Newell, W.H. | Borg, R.P.
In a dorsal plane, an improved ultrasonographic off-set system was used to obtain serial ultrasonographic images with enhanced anatomic and pathologic detail of the tendons, ligaments, and associated structures of the limbs of 100 horses. The off-set provided good acoustic coupling between a linear array ultrasonographic transducer and the horse's skin. A water-soluble gel contained within the off-set had acoustic properties similar to those of mammalian soft tissues.
اظهر المزيد [+] اقل [-]Cutaneous laser-Doppler velocimetry in nine animal species
1991
The assessment of cutaneous microcirculation by laser-Doppler velocimetry (LDV) has been primarily limited to human studies. The purpose of this investigation was to establish normal values in various species and anatomic sites for blood flow, velocity, and volume as determined by LDV. Microcirculation was measured with a laser-Doppler velocimeter in 54 animals, 6 healthy animals from each of 9 species. The standard sites used were the buttocks, convex surface of the ear, metacarpal pad, humeroscapular junction, thoracolumbar junction, ventral portion of the abdomen, dorsal metacarpus (hooved animals), and ventral surface of the tail (horse). Significant differences in blood flow, velocity, and volume were measured between species and sites within species. The ventral portion of the abdomen consistently had the highest relative blood flow across all species except the monkey. Measurements in the canine metacarpal pad had a high SD, possibly indicating the stratum corneum and epidermis to be too thick for LDV. Our findings provide baseline data in several species, with application of LDV in comparative dermatologic research.
اظهر المزيد [+] اقل [-]Ultrasonographic-anatomic correlation and an imaging protocol of the normal canine kidney
1990
Wood, A.K.W. | McCarthy, P.H.
Ultrasonographic or anatomic observations or both were made of the kidneys of 26 dogs. The anatomic studies established precise correlations between the gross anatomic features of the organ and its ultrasonographic images obtained in transverse, sagittal, dorsal, and 2 oblique planes. Uniformily mottled echogenicity of the renal cortex could be clearly differentiated from the less echogenic renal medulla. In the middorsal plane, the papillae of the renal pyramids were directed towards the renal sinus. The bases of the pyramids were almost circular in outline in the midsagittal images and the renal crest was seen as an echogenic line. Although the renal sinus was highly echogenic, neither the renal pelvis nor its recesses were detected. The walls of each of the interlobar arteries provided echogenic parallel lines, passing in the renal recesses between the renal pyramids. Arcuate arteries were demonstrated at the corticomedullary junction and interlobular arteries were detected within the renal cortex. For the right kidney, transverse images were obtained with the ultrasonographic transducer at the last 2 intercostal spaces; images in the dorsal, sagittal, and oblique planes were obtained with the transducer placed over the caudal extremity of the kidney. In the left kidney, transverse images were made with the transducers at, and caudal to, the last intercostal space; images in the dorsal, sagittal, and oblique planes were obtained with the transducer placed over the lateral border of the kidney. The use of such a protocol ensures that the entire organ is inspected and a diagnosis of either a normal or pathologic kidney is made.
اظهر المزيد [+] اقل [-]Ultrasonographic and biometric evaluation of the eye and orbit of dogs
1989
Cottrill, N.B. | Banks, W.J. | Pechman, R.D.
The normal B-scan ultrasonographic anatomic features of the eye and orbit of mesocephalic and dolichocephalic dogs were described. The B-scan appearance of ocular and orbital structures correlated well with the visual morphologic features of the specimens. The eyes of mesocephalic and dolichocephalic dogs were measured by use of ultrasonographic methods; those measurements were compared with direct measurements of the specimens. The 2-tailed Student t-test was used for all statistical analyses (P = 0.05). Measurements made included mid-cornea to anterior lens surface, lens thickness, vitreous body (posterior lens surface to retina), and axial globe length. The A-scan measurements of all 4 ocular distances were significantly different, compared with direct measurements. The B-scan measurements of mid-cornea to anterior lens surface, lens thickness, and vitreous body were significantly different from direct measurements; however, there was no significant difference between B-scan and direct measurements of axial globe length. There was no significant difference between A- and B-scan measurements. These findings suggest that A- and B-scan measurements are similar and that B-scan measurements are reasonably accurate for axial globe determination. Several variables were compared by B-scan and direct measurement methods. The axial globe length of dolichocephalic dogs was significantly longer than that of mesocephalic dogs. The axial globe length of male and female dogs was not significantly different in mescephalic or dolichocephalic dogs. There was no difference in the axial globe length of right and left eyes in mesocephalic or dolichocephalic dogs.
اظهر المزيد [+] اقل [-]In vitro ultrasonographic appearance of the normal and verminous equine aorta, cranial mesenteric artery, and its branches
1989
Wallace, K.D. | Selcer, B.A. | Tyler, D.E. | Brown, J.
Ninety-one equine aortic and cranial mesenteric arterial segments were evaluated ultrasonographically in a water bath. On the basis of pathologic evidence of verminous arteritis, arterial segments were classified into 4 categories, and the ultrasonographic characteristics of each group were evaluated. Normal arteries (class 1) were ultrasonographically characterized by a smooth luminal surface layer and uniform wall thickness and echogenicity. Arteries with only histopathologic evidence of verminous arteritis (class 2) were ultrasonographically characterized by a smooth luminal surface layer, uniform thickness, uniform echogenicity, and the presence of a hyperechoic luminal layer. Arteries with both gross and histopathologic evidence of verminous arterities (class 3) were characterized ultrasonographically by an irregular luminal surface layer, varying wall thickness, varying wall echogenicity, and the presence of a hyperechoic luminal layer. The ultrasonographic characteristics of arteries with luminal thrombosis (class 4) were an irregular luminal surface, varying wall thickness, and nonuniform echogenicity.
اظهر المزيد [+] اقل [-]Effects of head position on internal and external carotid pressures in standing sedated horses
2021
Caffey, Stacy R. | Lund, Caleb M. | Farnsworth, Kelly D. | Fransson, Boel A. | Ragle, Claude A.
The effects of head position on internal carotid artery (ICA) and external carotid artery (ECA) pressures in standing sedated horses were evaluated in this study. The common carotid artery (CCA) was catheterized in 6 horses using an ultrasound-guided technique to facilitate placement of a pressure transducer within the ICA and ECA at the level of the guttural pouch. Transducer position was confirmed by endoscopic visualization. Mean arterial pressure (MAP) was measured with horses in both a head-up and head-down position. The dorsal metatarsal artery was catheterized as a control. Maintaining a head-up position decreased MAP in both the ICA (median: 75.21 mmHg) and ECA (median: 79.43 mmHg), relative to the head-down position (ICA median: 104.65 mmHg; ECA median: 102.26 mmHg). Mean arterial pressure in the dorsal metatarsal artery was not affected by head position. The head-up position resulted in lower arterial pressures in both the ICA and ECA (P = 0.03) compared with the head-down position in standing sedated horses.
اظهر المزيد [+] اقل [-]Biochemical, functional, and histopathologic characterization of lomustine-induced liver injury in dogs
2020
Dedeaux, Andrea M. | Flesner, Brian K. | Reinhart, Jennifer M. | Langohr, Ingeborg M. | Husnik, Roman | Geraci, Shawn N. | Toboada, Joseph | Rademacher, Nathalie | Thombs, Lori A. | Bryan, Jeffrey N. | Trepanier, Lauren A. | Boudreaux, Bonnie B.
OBJECTIVE To characterize the biochemical, functional, and histopathologic changes associated with lomustine-induced liver injury in dogs. ANIMALS I0 healthy purpose-bred sexually intact female hounds. PROCEDURES Dogs were randomly assigned to receive lomustine (approx 75 mg/m2, PO, q 21 d for 5 doses) alone (n = 5) or with prednisone (approx 1.5 mg/kg, PO, q 24 h for 12 weeks; 5). For each dog, a CBC, serum biochemical analysis, liver function testing, urinalysis, and ultrasonographic examination of the liver with acquisition of liver biopsy specimens were performed before and at predetermined times during and after lomustine administration. Results were compared between dogs that did and did not receive prednisone. RESULTS 7 of the I0 dogs developed clinical signs of liver failure. For all dogs, serum alanine aminotransferase (ALT) and alkaline phosphatase (ALP) activities, bile acid concentrations, and liver histologic score increased and hepatic reduced glutathione content decreased over time. Peak serum ALT (r = 0.79) and ALP (r = 0.90) activities and bile acid concentration (r = 0.68) were positively correlated with the final histologic score. Prednisone did not appear to have a protective effect on histologic score. CONCLUSIONS AND CLINICAL RELEVANCE In dogs, liver enzyme activities, particularly ALT and ALP activities, should be closely monitored during lomustine treatment and acute increases in those activities may warrant discontinuation of lomustine to mitigate liver injury. Nonspecific ultrasonographic findings and abnormal increases in liver function tests were not detected until the onset of clinical liver failure. Glutathione depletion may have a role in lomustine-induced hepatopathy and warrants further investigation.
اظهر المزيد [+] اقل [-]Effects of transrectal palpation with the fetal membrane slip technique for early pregnancy diagnosis on the proportion and type of associated pregnancy loss in dairy cattle
2020
Romano, Juan E. | Thompson, James A. | Kraemer, Duane C. | Forrest, David W.
OBJECTIVE To assess the effect of transrectal palpation (TRP) performed with the fetal membrane slip (FMS) technique for early pregnancy diagnosis on the proportion and type of associated pregnancy losses (PLs) in dairy cattle. ANIMALS 580 healthy pregnant cattle. PROCEDURES Data for artificially inseminated females with 1 or 2 viable embryos detected by transrectal ultrasonography (TRUS) at approximately 30 days of gestation were retrospectively assessed. Cattle were assigned to 1 of 2 groups on the basis of whether they did or did not undergo TRP once between 34 and 41 days of gestation (palpation and control group, respectively). At approximately 45 and 60 days of gestation, all cattle were reevaluated by TRUS; PL was categorized as type I (FMS detectable by TRP and TRUS-confirmed evidence of embryo or fetus degeneration and a functional corpus luteum) or type II (FMS undetectable by TRP and no TRUS-confirmed evidence of an embryo or fetus or of a functional corpus luteum). RESULTS Of the 580 healthy pregnant cattle, 271 underwent TRP and 309 did not. In the palpation and control groups, PL occurred in 40 (14.8%) and 47 (15.2%) cattle, respectively. Among the palpation group's PLs, 17 (43%) were type I and 23 (58%) were type II. Among the control group's PLs, 27 (57%) were type I and 20 (43%) were type II. The prevalance and type of PL did not differ between groups. CONCLUSIONS AND CLINICAL RELEVANCE TRP with the FMS technique for early pregnancy diagnosis did not increase the prevalence of PL in dairy cattle or alert the proportion of type I versus type II PL.
اظهر المزيد [+] اقل [-]Radiographic evaluation of patellar ligament length after tibial plateau leveling osteotomy in dogs
2019
Jay, Maureen R. | Mattoon, John S. | Gilbert, Peter J. | Tanaka, Ty T. | Beaty, Brenda L.
OBJECTIVE To radiographically compare patellar ligament length (PLL) in dogs undergoing tibial plateau leveling osteotomy (TPLO) for unilateral cranial cruciate ligament rupture at preoperative, postoperative, and follow-up evaluations. ANIMALS 105 dogs that underwent TPLO for unilateral cranial cruciate ligament rupture at a referral veterinary hospital from October 1, 2008, through November 30, 2017. PROCEDURES Medical records were reviewed to obtain information on dog signalment, surgical procedure, and radiographically measured PLL at preoperative, postoperative, and follow-up evaluations. RESULTS Dogs undergoing TPLO had a shorter PLL at the postoperative and follow-up evaluations, compared with the PLL at the preoperative evaluation. Mean ± SD overall unadjusted PLL decreased significantly by 2.3 ± 3.4% between the preoperative and postoperative evaluation and by 2.8 ± 3.9% between the preoperative and follow-up evaluation. The PLL did not differ significantly between the postoperative and follow-up evaluation; mean PLL decreased by 0.4 ± 3.8% between the postoperative and follow-up evaluation. CONCLUSIONS AND CLINICAL RELEVANCE The PLL was shorter after TPLO in dogs, which was similar to changes observed for humans after high tibial osteotomy procedures. Further evaluation of clinical assessments, joint mobility, ultrasonographic assessments, and kinematic results are needed to determine the relevance of the PLL and whether a decrease in ligament length results in decreased mobility and persistent lameness in dogs, as has been reported for humans.
اظهر المزيد [+] اقل [-]Effect of catheter diameter and injection rate of flush solution on renal contrast-enhanced ultrasonography with perfluorobutane in dogs
2019
Hwang, Jaewoo | Kang, Kyuyong | Kang, Jiwon | Nam, Jihye | Park, Saechol | Yoon, Junghee | Choi, Mincheol
OBJECTIVE To assess effects of catheter diameter and injection rate of flush solution (saline [0.9% NaCl] solution) on renal contrast-enhanced ultrasonography (CEUS) with perfluorobutane in dogs. ANIMALS 5 healthy Beagles. PROCEDURES CEUS of the kidneys was performed by IV injection of contrast medium (0.0125 mL/kg) followed by injection of 5 mL of saline solution at rates of 1, 3, and 5 mL/s through a 20-gauge or 24-gauge catheter; thus, CEUS was repeated 3 times for each catheter diameter. Time-intensity curves were created for regions of interest drawn in the renal cortex and medulla. Repeatability was determined by calculating the coefficient of variation (CV). Statistical analysis was used to assess whether perfusion variables or CV of the perfusion variables was associated with catheter diameter or injection rate. RESULTS Perfusion variables did not differ significantly between catheter diameters. Time to peak enhancement (TTP) in the renal cortex was affected by injection rate, and there were significantly lower values for TTP at higher injection rates. The CEUS variables with the lowest CVs among injection rates were TTP for the renal cortex; the CV for TTP of the renal cortex was the lowest at an injection rate of 5 mL/s. CONCLUSIONS AND CLINICAL RELEVANCE Use of a 24-gauge catheter did not alter CEUS with perfluorobutane; therefore, such catheters could be used for CEUS of the kidneys of small dogs. Moreover, a rate of 5 mL/s is recommended for injection of flush solution to obtain greater accuracy for renal CEUS in Beagles.
اظهر المزيد [+] اقل [-]