خيارات البحث
النتائج 251 - 260 من 513
Mucosal and systemic antibody responses to bovine coronavirus structural proteins in experimentally challenge-exposed calves fed low or high amounts of colostral antibodies
1991
Heckert, R.A. | Saif, L.J. | Mengel, J.P. | Myers, G.W.
Ten colostrum-deprived calves were assigned to 1 of 2 treatment groups (5 calves/group), and fed colostrum that had either low (naturally infected cows) or high (immunized cows) antibody titers to bovine coronavirus (BCV). All calves were inoculated orally and intranasally with virulent BCV when they were 24 to 48 hours old and challenge exposed 21 days later. Blood, feces, nasal secretions, tears, saliva, and bronchoalveolar lavage (BAL) fluids were collected weekly from each calf for 5 weeks after inoculation. The titers to whole BCV or the relative amounts of isotype-specific antibodies to BCV structural proteins were evaluated in these samples by ELISA or immunoblotting, respectively. Both pools of colostrum contained primarily IgG1, IgG2, and IgA antibodies to the E2 and E3 BCV proteins. Calves fed the high-titer colostrum had correspondingly higher amounts of passive IgG1 and IgA antibodies to whole BCV and to the E2 and E3 BCV proteins in serum, feces, and BAL fluid at postinoculation week 1 than those calves fed low-titer colostrum. Active IgG1, IgA and IgM antibody responses in serum and active IgA and IgM antibody responses in most mucosal secretions to whole BCV and to the E2 and E3 proteins were lower or delayed in calves fed high-titer colostrum, compared with responses in calves fed low-titer colostrum. In contrast, increased responses to the BCV N protein were observed in all samples (except in serum and BAL fluid) in the calves fed high-titer colostrum, compared with calves fed low-titer colostrum. Upon challenge exposure, responses to E2 and E3 BCV proteins in serum and BAL fluid were lower in the group fed high-titer colostrum, compared with those in the group fed low-titer colostrum. Our findings indicate that the level of passive immunity in calves at the time of BCV inoculation can influence the development of active antibody responses in serum, feces, and mucosal secretions to whole BCV and to some BCV proteins individually.
اظهر المزيد [+] اقل [-]Comparison of fractional excretion and 24-hour urinary excretion of sodium and potassium in clinically normal cats and cats with induced chronic renal failure
1991
Adams, L.G. | Polzin, D.J. | Osborne, C.A. | O'Brien, T.D.
The influence of induced chronic renal failure on 24-hour urinary excretion and fractional excretion of sodium and potassium was studied in cats. Induction of chronic renal failure significantly increased fractional excretion of potassium (P < 0.0001) and sodium (P < 0.05); however, 24-hour urinary excretion of sodium and potassium decreased slightly following induction of chronic renal failure. Fractional excretion and 24-hour urinary excretion of sodium and potassium were compared by linear regression in clinically normal cats, cats with chronic renal failure, and clinically normal and affected cats combined. In clinically normal cats, linear regression revealed only moderate correlation between fractional excretion and 24-hour urinary excretion for sodium and potassium. Linear regression of these same relationships in cats with chronic renal failure, and in clinically normal cats and cats with chronic renal failure combined, indicated low correlation. Fractional excretions of sodium and potassium were not reliable indicators of 24-hour urinary excretion of these electrolytes in cats with chronic renal failure or unknown glomerular filtration rate. Fractional excretion of potassium and sodium correlated only moderately with urinary excretion in clinically normal cats.
اظهر المزيد [+] اقل [-]Axial pattern flap based on the caudal auricular artery in dogs
1991
Smith, M.M. | Payne, J.T. | Moon, M.L. | Freeman, L.E.
An axial pattern flap that was based on the sternocleidomastoideus branches of the caudal auricular artery and vein was developed. Control flaps, which included ligation and division of the caudal auricular artery and vein, were similarly developed on the contralateral aspect of the neck. Mean survival of caudal auricular artery axial pattern flaps (85.2%), compared with control flaps (63.9%), was significantly different (P < 0.05). On the basis of results of this study, an axial pattern flap based on the sternocleidomastoideus branches of the caudal auricular artery and vein may be a source of skin for reconstructive procedures of the head and neck.
اظهر المزيد [+] اقل [-]Analysis of selected variables in the under-agarose assay for chemotactic responses of canine neutrophils
1991
Nagahata, H. | Kociba, G.J. | Reiter, J.A. | Couto, C.G.
Chemotaxis under agarose was evaluated to establish an assay system and to characterize chemotacticresponses of canine neutrophils. A method for the measurement of canine neutrophil chemotaxis was established, with optimal responses obtained with agarose containing 10% pooled canine serum, a concentration of 5 X 10(5) cells/well, zymosan-activated serum (ZAS), or autologous serum or plasma as the chemoattractants, and a 120-minute incubation period. Canine neutrophils responded well to ZAS, heat-inactivated ZAS, autologous serum and plasma, and heat-inactivated pooled serum. Chemotactic activity was proportional to the concentration of serum used as the chemoattractant. Mean (+/- SD) random migration, chemotaxis, chemotactic index, and chemotactic differential of neutrophils from 9 healthy Greyhounds were 1.09 (+/- 0.23), 1.95 (+/- 0.38), 1.82 (+/- 0.31), and 0.86 (+/- 0.32) mm,respectively.
اظهر المزيد [+] اقل [-]Effects of topical administration of 2.0% pilocarpine on intraocular pressure and pupil size in cats
1991
Wilkie, D.A. | Latimer, C.A.
Effects of topical administration of a single dose of 2% pilocarpine on intraocular pressure (IOP) and pupil diameter were evaluated in normotensive eyes of 10 clinically normal cats over 12 hours. Mean (+/- SEM) normal IOP was 17.1 (+/- 1.1) mm of Hg and, diurnal fluctuation was observed, with the highest IOP seen in the evening. Mean (+/- SEM) normal pupil diameter was found to be 10.1 (+/- 0.5) mm. Topical treatment with pilocarpine resulted in reduction of IOP in treated and nontreated eyes. This effect was time-dependent and was first observed at 4 hours after treatment. Mean reduction of IOP was 15.2% in the treated eye and 9.3% in the nontreated eye. The treated eye had reduced pupil diameter at 30 minutes after treatment, and miosis persisted throughout the 12 hours of the study. Mean reduction in pupil diameter was 28.5% in the treated eye and 14.2% in the nontreated eye. Topically administered pilocarpine results in reduction of IOP and pupil diameter in treated and contralateral eyes, which supports the use of pilocarpine for treatment of glaucoma in cats.
اظهر المزيد [+] اقل [-]Effects of amiodarone on myocardial performance in normal canine hearts and canine hearts with infarcts
1991
Ware, W.A. | Muir, W.W. | Swanson, C.
The effects of IV administered amiodarone, a class-III antiarrhythmic agent, on myocardial contractility, early myocardial relaxation, and hemodynamic variables were evaluated in normal canine hearts and those with infarcts. In the normal canine heart, amiodarone had important, but relatively mild, depressant effects on left ventricular contractility (assessed by maximal positive first derivative of left ventricular pressure (+dP/dt(max)) and maximal elastance (Emax)) and heart rate when given IV at a dose of 10 mg/kg of body weight. An effect on contractility or active relaxation (assessed by maximal negative first derivative of left ventricular pressure(-dP/dt(max)) and the time constant of isovolumic pressure decrease) was not identified with smaller doses. Myocardial infarction itself caused a predictable and marked depressant effect on myocardial contractility, as indicated by decreases in +dP/dt(max) ejection fraction, Emax, and-dP/dt(max), and elevation in end diastolic pressure. Additional depressive effects on contractility and active relaxation resulted when 10 mg of amiodarone/kg was administered to dogs with myocardial infarction and these effects were sufficient to worsen acute myocardial infarction-induced heart failure. Significant changes attributable to heart rate alone could not be identified. On the basis of our findings, we suggest that amiodarone administered IV should be used with caution in dogs with compromised ventricular function.
اظهر المزيد [+] اقل [-]Effect of milk stasis on Brucella abortus infection of the mammary gland in goats
1991
Meador, V.P. | Deyoe, B.L.
To compare the effects of milk stasis and milk flow on Brucella abortus infection of the mammary gland under the same systemic conditions, primiparous goats (n = 5) were inoculated IV with B abortus on the day of parturition, and suckling by their neonates was restricted to one mammary gland. Goats were euthanatized and necropsied at 3 weeks after inoculation, and milk, mammary glands, and supramammary lymph nodes were evaluated by bacteriologic, histologic, and immunoenzymatic staining techniques. Nonnursed mammary glands had high titers of brucellae in milk, moderate interstitial mastitis, and brucellar antigen in macrophages located primarily in alveolar and ductal lumina. Brucellae often filled the macrophage cytoplasm. In contrast, nursed mammary glands had fewer brucellae in milk, minimal inflammatory changes, and no detectable brucellar antigen in histologic sections. Hyperplastic changes were only seen in supramammary lymph nodes draining nonnursed mammary glands; these contained more brucellae than lymph nodes draining nursed mammary glands. These studies show that milk stasis may be the sole cause of increased susceptibility of nonnursed mammary glands to B abortus infection.
اظهر المزيد [+] اقل [-]Evaluation of the oral vitamin E absorption test in horses
1991
Craig, A.M. | Blythe, L.L. | Rowe, K.E. | Lassen, E.D. | Walker, L.L.
An oral vitamin E absorption test used in human beings was modified for use in horses. The most appropriate techniques with which to measure gastrointestinal tract absorption of vitamin E (alpha-tocopherol) in horses weredeveloped. Vitamin E was administered orally, and serum values of alpha-tocopherol were measured by use ofhigh-performance liquid chromatography at 0, 3, 6, 9, 12, and 24 hours after vitamin E administration. Variables included comparison of 2 dosages (45 and 90 IU/kg of body weight), routes of administration, and absorption dynamics of 3 preparations of dl-alpha-tocopherol. Absorption of the 2 doses of dl-alpha-tocopherol acetate indicated a dose response; the area under the curve at 24 hours (AUC24) was 4.3 micrograms.h/ml for the 45-IU/kg dose and 32.2 micrograms.h/ml (P < 0.01) for the 90-IU/kg dose. Maximal absorption was apparent when vitamin E was naturally consumed in grain, compared with administration of identical preparations by stomach tube or paste. In the same horses, dl-alpha-tocopherol and dl-alpha-tocopherol acetate plus polyethylene glycol had statistically similar absorption curves and both had significantly greater AUC24, compared with dl-alpha-tocopherol acetate; values for the 3 compounds were 23.6, 25.8, and 12.6 micrograms.h/ml, respectively. The AUC24 varied betweenindividual horses, but time of peak value was consistently observed between 6 and 9 hours. On the basis of the data from this study, the recommended technique for performing the oral vitamin E absorption test in horses would be administration of 90 IU of the free form of dl-alpha-tocopherol/kg, mixed in 1 L of grain to horses from which food has been withheld for 12 hours, followed by allowing the horses ad libitum access to hay immediately after administration of the vitamin E. Three baseline serum alpha-tocopherol values should be obtained within 24 hours prior to the test, with the last sample being obtained just prior to administration of the test dose of vitamin E. Heparinized plasma also may be used for this testing procedure. alpha-Tocopherol concentration should be measured at 3, 6, 9, 12, and 24 hours after vitamin E administration.
اظهر المزيد [+] اقل [-]Prevalence of calcium oxalate uroliths in Miniature Schnauzers
1991
Lulich, J.P. | Osborne, C.A. | Unger, L.K. | Sanna, J. | Clinton, C.W. | Davenport, M.P.
Epidemiologic data were evaluated from all dogs admitted to the University of Minnesota, Veterinary Teaching Hospital (UMVTH) between June 1981 and November 1989. Of 69,890 admissions, 2,077 were Miniature Schnauzers. Uroliths were retrieved from 63 of the 2,077 Miniature Schnauzers admitted. In 20 of the 63 urolith episodes, calcium oxalate was the predominant mineral identified. By comparison, calcium oxalate uroliths were identified in only 56 of the remaining 67,813 non-Miniature Schnauzer canine admissions. The odds that uroliths from Miniature Schnauzers were composed of calcium oxalate was 11.8 times greater than for other canine breeds evaluated at the UMVTH (95% confidence interval = 6.8 to 20.1). Data also were evaluated from files of uroliths retrieved from dogs and submitted to the Minnesota Urolith Center for quantitative mineral analysis between June 1981 and November 1989. Of 3,930 uroliths analyzed, 615 (15.6%) uroliths were obtained from Miniature Schnauzers. Of the 615 uroliths, 175 (28.4%) were calcium oxalate. By comparison, only 550 (16.6%) of the remaining 3,315 from dogs of breeds other than Miniature Schnauzers were calcium oxalate. The odds that uroliths submitted for analysis were composed of calcium oxalate was 2 times greater for Miniature Schnauzers than for dogs of other breeds (95% confidence interval = 1.6 to 2.4). Calcium oxalate uroliths were retrieved more frequently in males than females. The risk for males developing calcium oxalate uroliths was > 3 times the risk for females in both groups of data evaluated. The mean age of all Miniature Schnauzers admitted to the UMVTH with calcium oxalate uroliths was 9 years. Calcium oxalate uroliths were not detected in Miniature Schnauzers younger than 1.7 years.
اظهر المزيد [+] اقل [-]An ultrasonographic off-set system for examination of equine tendons and ligaments
1991
Wood, A.K.W. | Newell, W.H. | Borg, R.P.
In a dorsal plane, an improved ultrasonographic off-set system was used to obtain serial ultrasonographic images with enhanced anatomic and pathologic detail of the tendons, ligaments, and associated structures of the limbs of 100 horses. The off-set provided good acoustic coupling between a linear array ultrasonographic transducer and the horse's skin. A water-soluble gel contained within the off-set had acoustic properties similar to those of mammalian soft tissues.
اظهر المزيد [+] اقل [-]