Evaluation of epiduroscopy for detection of vertebral canal and spinal cord lesions in dogs
2016
Garcia-Pereira, Fernando L. | Prange, Timo | Seller, Aaron | Obert, Vicotria
OBJECTIVE To evaluate the potential usefulness of epiduroscopy for clinical diagnosis and treatment of vertebral canal and spinal cord lesions in dogs. SAMPLE Cadavers of 6 mixed-breed dogs. PROCEDURES Dogs were positioned in sternal recumbency, and an endoscope was introduced into the lumbosacral epidural space. A fiberscope (diameter, 0.9 mm; length, 30 cm) was used for 3 dogs, and a videoscope (diameter, 2.8 mm; length, 70 cm) was used for the other 3 dogs. Visibility and identities of anatomic structures were recorded, and maneuverability of the endoscopes was assessed. Extent of macroscopic tissue damage was evaluated by manual dissection of the vertebral canal at the end of the procedure. RESULTS Intermittent saline (0.9% NaCl) solution infusion, CO2 insufflation, and endoscope navigation improved visualization by separating the epidural fat from the anatomic structures of interest. Images obtained with the fiberscope were small and of poor quality, making identification of specific structures difficult. Maneuverability of the fiberscope was difficult, and target structures could not be reliably reached or identified. Maneuverability and image quality of the videoscope were superior, and spinal nerve roots, spinal dura mater, epidural fat, and blood vessels could be identified. Subsequent manual dissection of the vertebral canal revealed no gross damage in the spinal cord, nerve roots, or blood vessels. CONCLUSIONS AND CLINICAL RELEVANCE A 2.8-mm videoscope was successfully used to perform epiduroscopy through the lumbosacral space in canine cadavers. Additional refinement and evaluation of the technique in live dogs is necessary before its use can be recommended for clinical situations.
اظهر المزيد [+] اقل [-]The effects of lidocaine or a lidocaine-bupivacaine mixture administered into the infraorbital canal in dogs
2016
Pascoe, Peter J.
OBJECTIVE To determine the onset, duration, and extent of regional nerve blocks performed by administration of lidocaine or lidocaine-bupivacaine into the infraorbital canal in dogs. ANIMALS 6 healthy hound-type dogs. PROCEDURES Under general anesthesia, stimulating needles were inserted into the gingiva dorsolateral to both maxillary canine (MC) teeth and the maxillary fourth premolar (MPM4) and second molar (MM2) teeth on the treatment side. A reflex-evoked muscle potential (REMP) was recorded from the digastricus muscle after noxious electrical stimulation at each site. After baseline measurements, 1 mL of 2% lidocaine solution or a 2% lidocaine-0.5% bupivacaine mixture (0.5 mL each) was injected into the infraorbital canal (at approx two-thirds of the canal length measured rostrocaudally). The REMPs were recorded for up to 7 hours. The REMP data for the contralateral (untreated control) canine tooth were used to normalize results for all stimulation sites. RESULTS With both treatments, nerve block for MC teeth on the treated side was achieved by 5 (n = 5 dogs) or 10 (1) minutes after injection, but nerve block for ipsilateral MPM4 and MM2 teeth was successful for only 3 dogs and 1 dog, respectively. Mean duration of nerve blocks for MC teeth was 120 and 277 minutes following injection of lidocaine and lidocaine-bupivacaine, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Local anesthesia, as performed in this study, successfully blocked innervation of MC teeth, but results for MPM4 and MM2 teeth were inconsistent. This specific technique should not be used during tooth extractions caudal to the MC teeth.
اظهر المزيد [+] اقل [-]Effects of repeated gas sterilization on closure rates of ameroid ring constrictors in vitro
2016
Kimberlin, William W. | Wardlaw, Jennifer L. | Madsen, Richard W.
OBJECTIVE To determine the effect of repeated gas sterilization on rate of closure of ameroid ring constrictors in vitro. SAMPLE Twenty-four 3.5-mm ameroid ring constrictors. PROCEDURES Ameroid ring constrictors were allocated to 1 of 4 treatment groups (6/group) to undergo gas sterilization 0, 1, 5, or 10 times. After sterilization, constrictors were incubated in canine plasma at a protein concentration of 3 g/dL for 27 days. A digital camera was used to obtain images of the constrictors prior to and at various points during incubation, and lumen diameter was measured. RESULTS Mean ± SD percentage of lumen closure for all groups of ameroid ring constrictors combined was 85.2 ± 1.6% at day 0 (prior to plasma incubation) and 95.4 ± 0.8% at day 27. Mean lumen area was 3.64 ± 0.43 mm2 (95% confidence interval, 2.67 to 4.77 mm2) at day 0 and 1.32 ± 0.25 mm2 (95% confidence interval, 0.76 to 2.04 mm2) at day 27. None of the ameroid ring constrictors had closed completely by day 27. CONCLUSIONS AND CLINICAL RELEVANCE Overall closure rates for ameroid ring constrictors appeared to be unaffected by repeated gas sterilization up to 10 times. Findings suggested that veterinary surgeons can resterilize ameroid ring constrictors up to 10 times with confidence that ring properties would remain suitable for clinical use.
اظهر المزيد [+] اقل [-]Comparison of blood pressure measurements of anesthetized dogs obtained noninvasively with a cylindrical blood pressure cuff and an anatomically modified conical blood pressure cuff
2016
Ramos, Sara J. | Da Cunha, Anderson F. | Domingues, Michelle | Shelby, Amanda M. | Stout, Rhett W. | Acierno, Mark J.
OBJECTIVE To compare blood pressure measured noninvasively with an oscillometric device that involved use of a novel conical cuff and a traditional cylindrical blood pressure cuff. ANIMALS 17 adult hound-type dogs. PROCEDURES Dogs were anesthetized, and a 20-gauge, 1.5-inch catheter was inserted in the median sacral artery. The catheter was attached to a pressure transducer via fluid-filled noncompliant tubing, and direct blood pressure was recorded with a multifunction monitor. A specially fabricated conical cuff was placed on the antebrachium. Four sets of direct and indirect blood pressure measurements were simultaneously collected every 2 minutes. Four sets of measurements were then obtained by use of a cylindrical cuff. RESULTS The cylindrical cuff met American College of Veterinary Internal Medicine consensus guidelines for validation of indirect blood pressure measurements for mean arterial blood pressure (MAP), systolic arterial blood pressure (SAP), and diastolic arterial blood pressure (DAP). The conical cuff met the consensus guidelines for difference of paired measurements, SD, and percentages of measurements within 10 and 20 mm Hg of the value for the reference method, but it failed a correlation analysis. In addition, although bias for the conical cuff was less than that for the cylindrical cuff for SAP, MAP, and DAP measurements, the limits of agreement for the conical cuff were wider than those for the cylindrical cuff for SAP and MAP measurements. CONCLUSIONS AND CLINICAL RELEVANCE On the basis of results of this study, use of a conical cuff for oscillometric blood pressure measurement cannot be recommended.
اظهر المزيد [+] اقل [-]Morphological characteristics of subchondral bone cysts in medial femoral condyles of adult horses as determined by computed tomography
2016
Walker, Wade T. | Silverberg, Jesse L. | Kawcak, Christopher E. | Nelson, Bradley B. | Fortier, Lisa A.
OBJECTIVE To determine morphological characteristics of subchondral bone cysts (SBCs) in medial femoral condyles (MFCs) of adult horses with orthopedic disease. SAMPLE CT scans of 7 MFCs with SBCs from 6 adult horses. PROCEDURES CT was used to determine the volume, surface area, and centers of the articular cyst opening and SBC in each MFC. Cysts were ordered from smallest to largest on the basis of volume. Osseous pathological characteristics of the MFC were assessed in the frontal plane. Three-dimensional distance of displacement between the center of the articular cyst opening and center of the cyst was determined for each SBC. Cyst surface area-to-volume ratio was evaluated and compared with that of a true sphere. RESULTS All SBCs had a defect in the subchondral bone plate at the cranial 15% to 20% of the MFC. Cyst center was located in a caudal, proximal, and abaxial direction with respect to the center of the articular cyst opening for each horse. Small- and intermediate-volume SBCs were irregular and multilobulated, whereas large-volume SBCs were smooth and discrete with a surface area-to-volume ratio approaching that of a sphere. CONCLUSIONS AND CLINICAL RELEVANCE Consistency in morphological characteristics suggested a common etiopathogenesis for SBCs in MFCs of adult horses. Cyst enlargement may have been attributable to a biomechanical predisposition to decrease the surface area-to-volume ratio, resulting in a spherical cyst.
اظهر المزيد [+] اقل [-]Effects of catheter shape, interelectrode spacing, and electrode size on transesophageal atrial pacing in dogs
2016
Sanders, Robert A. | Chapel, Emily H.
OBJECTIVE To determine effects of catheter shape, interelectrode spacing (IS), and electrode size (ES) on pacing threshold (PT), extraneous muscular stimulation (EMS), and zone of capture (ZOC) for dogs undergoing transesophageal atrial pacing (TAP). ANIMALS 10 purpose-bred dogs without cardiac conduction disturbances. PROCEDURES 7 configurations for TAP catheters were tested in each dog to evaluate effects of catheter shape (curved or straight), IS (5, 15, and 25 mm), and ES (2, 4, and 6 mm). Each catheter was passed into the esophagus to a location aboral to the heart and slowly withdrawn until atrial pacing was achieved. Then, catheters were withdrawn in 5-mm increments until pacing could not be achieved. Outcomes measured at each pacing site included PT, degree of EMS, and ZOC. RESULTS There was a significantly lower PT, wider ZOC, and less EMS for the curved catheter than for the straight catheter. An ES of 6 mm induced significantly more EMS than was induced by an ES of 2 or 4 mm. An IS of 5 mm induced significantly less EMS and a significantly narrower ZOC but required a significantly higher PT, compared with results for an ES of 15 or 25 mm. Additionally, there was a significant direct correlation between IS and ZOC. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that a curved catheter with multiple 4-mm electrodes that provides for variable IS would be ideal for TAP in dogs. IMPACT FOR HUMAN MEDICINE TAP catheters currently used in human medicine are straight. The PT in humans may potentially be reduced with curved catheters.
اظهر المزيد [+] اقل [-]Effects of a medetomidine-ketamine combination on Schirmer tear test I results of clinically normal cats
2016
Di Pietro, Simona | Macrì, Francesco | Bonarrigo, Tiziana | Giudice, Elisabetta | Palumbo Piccionello, Angela | Pugliese, Antonio
OBJECTIVE To evaluate the effects of a medetomidine-ketamine combination on tear production of clinically normal cats by use of the Schirmer tear test (STT) 1 before and during anesthesia and after reversal of medetomidine with atipamezole. ANIMALS 40 client-owned crossbred domestic shorthair cats (23 males and 17 females; age range, 6 to 24 months). PROCEDURES A complete physical examination, CBC, and ophthalmic examination were performed on each cat. Cats with no abnormalities on physical and ophthalmic examinations were included in the study. Cats were allocated into 2 groups: a control group (n = 10 cats) anesthetized by administration of a combination of medetomidine hydrochloride (80 μg/kg) and ketamine hydrochloride (5 mg/kg), and an experimental group (30) anesthetized with the medetomidine-ketamine combination and reversal by administration of atipamezole. Tear production of both eyes of each cat was measured by use of the STT I before anesthesia, 15 minutes after the beginning of anesthesia, and 15 minutes after administration of atipamezole. RESULTS Anesthesia with a medetomidine-ketamine combination of cats with no ophthalmic disease caused a significant decrease in tear production. The STT I values returned nearly to preanesthetic values within 15 minutes after reversal with atipamezole, whereas the STT I values for the control group were still low at that point. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that a tear substitute should be administered to eyes of cats anesthetized with a medetomidine-ketamine combination from the time of anesthetic administration until at least 15 minutes after administration of atipamezole.
اظهر المزيد [+] اقل [-]Feasibility of flexible endoscopic evaluation of swallowing in healthy dogs
2016
Marks, Stanley L. | Douthitt, Katie L. | Belafsky, Peter C.
OBJECTIVE To assess feasibility of flexible endoscopic evaluation of swallowing (FEES) in awake dogs, determine whether specific variables associated with the oropharyngeal phase of swallowing can be recognized, and evaluate the safety and tolerability of FEES. ANIMALS 6 healthy client-owned large- and giant-breed adult dogs. PROCEDURES A topical anesthetic was applied to the nasal passage of each dog, and a fiberoptic endoscope was passed transnasally until the tip of the scope was positioned in the oropharynx. All dogs voluntarily drank colored water followed by consumption of a commercial canned diet and then a kibble diet mixed with food color. During each swallow, laryngeal and pharyngeal anatomic structures were evaluated and depth of bolus flow prior to the pharyngeal phase of swallowing was assessed. Evidence of bolus retention in the vallecula or pyriform sinuses and laryngeal penetration of the bolus were recorded. RESULTS FEES was completed without major adverse events and was tolerated well by all 6 dogs. Mild, self-limiting epistaxis was noted for 2 dogs. The nasopharynx, oropharynx, and hypopharynx were observed in all dogs; movement of food boluses through the esophagus was observed in 2 dogs, and food boluses in the stomach were visible in 1 dog. Pharyngeal and laryngeal function was considered physiologically normal in all dogs. CONCLUSIONS AND CLINICAL RELEVANCE FEES appeared to be a feasible diagnostic tool for use in large- and giant-breed dogs. Studies are warranted in dogs with oropharyngeal dysphagia to determine whether FEES can be tolerated and whether it can augment videofluoroscopy findings.
اظهر المزيد [+] اقل [-]Efficacy of Fostera PRRS modified live virus vaccine against a Canadian heterologous virulent field strain of porcine reproductive and respiratory syndrome virus
2016
Savard, Christian | Alvarez, Fernando | Provost, Chantale | Chorfi, Younes | D'Allaire, Sylvie | Benoit-Biancamano, Maria-Odile | Gagnon, Carl A.
Vaccination is a useful option to control infection with porcine reproductive and respiratory syndrome virus (PRRSV), and several modified live-PRRSV vaccines have been developed. These vaccines have shown some efficacy in reducing the incidence and severity of clinical disease as well as the duration of viremia and virus shedding but have failed to provide sterilizing immunity. The efficacy of modified live-virus (MLV) vaccines is greater against a homologous strain compared with heterologous PRRSV strains. The objective of this study was to evaluate the efficacy of Fostera PRRS MLV vaccine in protecting against challenge with a heterologous field strain widely circulating in the swine herds of eastern Canada. Forty-six piglets were divided into 4 groups: nonvaccinated-nonchallenged; nonvaccinated-challenged; vaccinated-challenged; and vaccinated-nonchallenged. The animals were vaccinated at 23 d of age with Fostera PRRS and challenged 23 d later with a heterologous field strain of PRRSV (FMV12-1425619). Overall, the vaccine showed some beneficial effects in the challenged animals by reducing the severity of clinical signs and the viral load. A significant difference between nonvaccinated and vaccinated animals was detected for some parameters starting 11 to 13 d after challenge, which suggested that the cell-mediated immune response or other delayed responses could be more important than pre-existing PRRSV antibodies in vaccinated animals within the context of protection against heterologous strains.
اظهر المزيد [+] اقل [-]Cytological analysis of bronchoalveolar lavage fluid acquired by bronchoscopy in healthy ferrets: A pilot study
2016
Bercier, Marjorie | Langlois, Isabelle | Dunn, Marilyn | Helie, Pierre | Burns, Patrick | Gara-Boivin, Carolyn
The objective of this study was to investigate the normal cytological evaluation of bronchoalveolar lavage (BAL) fluid in healthy adult ferrets (N = 12). These ferrets underwent bronchoscopy and BAL using sterile saline [1.5 mL/kg body weight (BW)]. Percentage of fluid recovered, total leukocyte count, differential leukocyte count, and cell count of the epithelial lining fluid (ELF) were determined. The mean percentage of lavage volume recovered from the right lung and left lung were 67.8 ± 14.9% and 69.7 ± 20.0%, respectively. Gender (P = 0.12) and weight (P = 0.17) did not significantly affect the mean percentage of recovered volume. The mean percentage of recovered volume (P = 0.47) and the mean leukocyte count (P = 0.17) from the right and left lung were not significantly different. Macrophages were the main leukocyte component of the lavages, followed by neutrophils, lymphocytes, and eosinophils. The mean proportion of ELF in BAL fluid was 9.3 ± 3.7% v/v. Bronchoscopy is clinically useful for collecting good quality BAL samples for cytological analysis in ferrets. The leucocyte differential was established, which may help veterinarians to make better clinical decisions when treating respiratory disease. Further studies are required with a larger group in order to establish the healthy reference intervals for BAL values in ferrets.
اظهر المزيد [+] اقل [-]