خيارات البحث
النتائج 1 - 8 من 8
Phosphorus removal in constructed wetlands of subsurface and surface flow
2008
Gasiunas, V., Lithuanian Univ. of Agriculture, Kaunas (Lithuania). Water Management Inst. | Strusevicius, Z., Lithuanian Univ. of Agriculture, Kaunas (Lithuania). Water Management Inst.
Constructed wetland (CW) treatment systems are engineered systems designed to treat wastewater with the usage of the same processes that occur in natural wetlands. The full-scale investigations of free water flow surface filters (FWF), subsurface flow filters, including filters of vertical flow (SVF) and horizontal flow (SHF) were carried out in Lithuania. The investigations’ database collected within the study period of 1995-2007 was used for the estimation of phosphorus removal efficiency of different constructed wetlands. It was established that phosphorus removal efficiency depends on construction of filters and the load according to total phosphorus for the area unit of filter surface. Subsurface flow filters are distinguished by better phosphorus removal. At the same load of all filters, i.e., total phosphorus of 0.3 g mE-2 dE-1, the removal efficiency of subsurface flow horizontal, vertical, and free water flow filters reaches 53.0, 46.5 and 28.0%, respectively. The wastewater contains phosphorus in mineral and organic forms. Due to the aerobic conditions in filters of vertical flow, the amount of organic phosphorus removed by SVF is 3 times greater than in horizontal filters. Organic phosphorus in wastewater before the treatment by vertical filters constituted 27% of total P, and after the treatment 21%. In wastewater treated by horizontal filters this ratio was 21% and 31%, respectively.
اظهر المزيد [+] اقل [-]Research of treatment of wastewater from milk collection stations in sand filter
2008
Askinis, S., Lithuanian Univ. of Agriculture, Kaunas (Lithuania). Water Management Inst.
Highly polluted wastewater accumulates in milk collection stations. Its biochemical oxygen demand (BOD5) ranges from 369 to 1388 mg O2 lE-1. The average contamination was 600 mg O2 lE-1. There was a comparatively small amount of biogenic materials in it: total nitrogen – 27.3, total phosphorus – 5.0 mg lE-1. When variations of wastewater amounts are high, sand filters of vertical filtration are successfully used for the treatment of household wastewater. Model investigations were carried out to establish the possibilities of using these filters in treating wastewater in milk collection stations. The efficiency of wastewater treatment with these filters was 99.3% by BOD5, 99.1% – by suspended solids, 91.2% – by total nitrogen and 98.8% – by total phosphorus. According to the research results dependency equations were made; they were used to calculate the amount of main contaminants in milk collection stations that infiltrated through a layer of silt of diff rent thickness. The calculations showed that wastewater treatment to permissible limits is ensured by filtration through 0.6 m thick layer of sand. The average treatment level by BOD5 in such a filter of vertical filtration would be 20 mg O2 lE-1 and the treatment efficiency – 95.9%. Treatment efficiency of total nitrogen would be 88.1%, total phosphorus – 96.9, suspended solids – 95.5%. Preliminary research in the model showed that sand filters of vertical filtration can be used to treat wastewater from milk collection stations.
اظهر المزيد [+] اقل [-]Influence of the hydraulic load on the wastewater treatment efficiency in the filters with different filter media
2010
Kazakeviciene, J., Lithuanian Univ. of Agriculture, Akademija, Kauno reg. (Lithuania) | Askinis, S., Lithuanian Univ. of Agriculture, Vilainiai, Kedainiai (Lithuania). Faculty of Water and Land Management. Water Research Inst.
In order to avoid the problem of stoppage in the filters of vertical filtration, we tried to search for the filter media which was coarse and could clean the wastewater to the allowable contamination level. For this purpose the dolomite chippings were chosen and the modelling investigation was performed. Two modelled filters taking 0.2 square m area each were equipped: one was filled with the sand and the other was filled with the dolomite chippings. The results revealed that the initial contamination of the wastewater had a much bigger influence on the wastewater cleaning process than the hydraulic load. The wastewater was cleaned with the efficiency of 95.9% and never exceeded the allowable level of 30 mg O2 LE-1 in the dolomite chippings filter during the trial with the hydraulic load 0.03 m**3 mE-2 dE-1. When the hydraulic load was doubled the efficiency of the wastewater cleaning process decreased to 80.5% and the dependence of the cleaning process on the initial contamination of the wastewater increased. In order to ensure the successful removal of the easily decomposing organic pollutants from the wastewater up to their allowable contamination level, the quantity of the pollutants in the untreated wastewater must not exceed 220 mg O2 LE-1.
اظهر المزيد [+] اقل [-]Modelling of the wastewater treatment in the filters of vertical flow with the dolomite powder media
2010
Kazakeviciene, J., Lithuanian Univ. of Agriculture, Akademija, Kauno reg. (Lithuania) | Askinis, S., Lithuanian Univ. of Agriculture, Vilainiai, Kedainiai (Lithuania). Faculty of Water and Land Management. Water Research Inst.
The possibilities to use other media instead of the sand in the filters of vertical flow are analysed in the article. The media used has to be inexpensive and its possibilities to clean the wastewater have to surpass that of the sand. The modelling of the wastewater treatment in the vertical flow filters was carried out in 2008 at the Water Research Institute of the Faculty of Water and Land Management of Lithuanian University of Agriculture. Dolomite powder was chosen for the investigation. Two models of 0.2 square m filters were made: one was filled with the sand, but the other was filled with the dolomite powder. It was found that the dolomite filter was less reactive to the primary contamination of the wastewater with the organic pollutants: when their amount rose from 320 to 460 mg O2 LE-1 according to the BOD7 index, the amount of the pollutants in the wastewater cleaned with the dolomite powder filter rose from 1.4 to 3.1 and amount in the wastewater which passed the sand filter rose from 0.5 to 13.9 mg O2 LE-1. General phosphorus was removed with the efficiency of 99.9% in the dolomite powder filter (and only with the efficiency of 87.0% in the sand filter). Therefore the dolomite powder filter will be removing phosphorus from the wastewater to the allowable contamination level for a much longer period. General nitrogen was cleaned with the effectiveness of 13.0% in the dolomite powder filter. Therefore, it is necessary to use additional means for its removal from the wastewater in the vertical filters with the output higher than 5 m**3 dE-1.
اظهر المزيد [+] اقل [-]Distribution of nitrogen and phosphorus compounds in filter media of constructed wetland
2010
Gasiunas, V., Lithuanian Univ. of Agriculture, Vilainiai, Kedainiai (Lithuania). Faculty of Water and Land Management. Water Research Inst.
The objective of the present studies is to estimate a distribution of nitrogen and phosphorus compounds in filter media of horizontal filters. The studies were carried out in 2009 within two wastewater treatment facilities of horizontal flow in Lithuania. From both treatment facilities sand samples of different depth and separate profiles in the direction of water flow were taken. These samples were used to determine sandmoisture and concentration of N-NO3, N-NH4 and total P. The measurements of sand moisture showed that the filtration of wastewater through the sand is in process only in the lower layer of sand filter and near the distribution pipe. Moisture regime in the sand influences the composition of nitrogenous compounds in it. In the part of the filter, where sand's moisture is lowest, nitrate concentration is highest. Ammonia concentrations are completely opposite. In the lower part of the filter anaerobic conditions are dominant and nitrification processes stop. Analysis of phosphorus concentrations in filter's sand showed similar tendencies as nitrogen analysis. In the upper part of the sand phosphorus concentration turns out to be 2-3 times lower than in the lower part of the sand. In the filters of horizontal flow, part of the sand contributes little or does not contribute to the wastewater treatment process at all; therefore, it is advisable to use wastewater recirculation for the improvement of nitrogen and phosphorus removal. For that purpose in the part of the filter not included in the treatment process the filter of vertical flow could be arranged.
اظهر المزيد [+] اقل [-]Influence of the vertical filter media on phosphorus removal from the domestic wastewater
2011
Kazakeviciene, J., Lithuanian Univ. of Agriculture, Vilainiai, Kedainiai (Lithuania). Faculty of Water and Land Management. Water Research Inst. | Askinis, S., Lithuanian Univ. of Agriculture, Vilainiai, Kedainiai (Lithuania). Faculty of Water and Land Management. Water Research Inst.
Modelling of the domestic wastewater treatment and removal of the Ptotal in the vertical filters with the sand, dolomite powder and dolomite chippings each separately used as a filter media was performed. Six filter models taking 0.2 m2 each were installed. The length of the filtration path was equal to 0.8 m in three of these models and 0.4 m in the other three models. The hydraulic load on the filters was equal to 0.03 m3 mE-2 dE-1 in 2008, and it was equal to 0.06 m3 mE-2 dE-1 in 2009. The domestic wastewater which had undergone the pre-cleaning in the septic systems was poured into the models. Their average pollution with the Ptotal reached 14.6 mg LE-1 in the first year and 9.2 mg LE-1 in the second year. When the filtration path was equal to 0.8 m and the hydraulic load was equal to 0.03 m3 mE-2 dE-1, the Ptotal was removed from the wastewater with the efficiency of 99.9% in the dolomite powder filter. In the filter models with the sand and dolomite chippings, the Ptotal was removed with the same efficiency of 87.7%. When the hydraulic load doubled, the efficiency of P removal decreased to 59.8% in the sand filter and down to 45.7% in the dolomite chippings filter. When the hydraulic load reached 0.06 m3 mE-2 dE-1, only the dolomite powder filter could ensure the adequate cleaning of the domestic wastewater up to the allowable norms.
اظهر المزيد [+] اقل [-]Nitrogen removal in constructed wetlands of vertical and horizontal flow
2006
Gasiunas, V. | Strusevicius, Z.
Constructed wetlands (CW) are considered as one of principal wastewater treatment methods containing and soil filters. CW may be of subsurface vertical flow (VF) and horizontal flow (HF). The objective of the studies was to estimate N-removal efficiency differences in CW of vertical and horizontal flow. To evaluate nitrogen (N) removal efficiency, the database of the studies on both construction of CW collected within the period of 1995-2005 was used. Horizontal filter systems characterize for a 1.6 times higher N-removal efficiency than vertical filters. Generally, N-removal efficiency depends on the load of filters. When filter load was 1.5 g mE-2dE-1 according to TN, N-removal efficiency is 39.6 and 24.0% in HF and VF systems respectively. Considering the seasons of the year, no significant difference was observed in N-removal efficiency in HF and VF systems during cold and warm periods of the year. N contained in water after the treatment process in filters is detected in different forms. NH4-N is prevailing in HF, while in VF systems NO3-N is dominant. It was also observed that NH4-N in the effluent during the initial operation of VF after the construction works in the first two months in the warm and in four months during their operation in the cold period of the year was prevailing.
اظهر المزيد [+] اقل [-]Investigations on P-removal processes from wastewater applying mineral filters
2006
Strusevicius, Z. | Struseviciene, S.M.
In the process of biological wastewater treatment, P-removal is efficient enough when the concentration of organic pollutants according to BOD5 (biochemical oxygen demand) is no higher than 190 mg lE-1 of O2 and its relationship with phosphorus does not exceed 20. Having studied the composition of wastewater from dairy farms it was determined that wastewater pollution according to BOD5 is from 800 to 900 mg lE-1 of O2 and the ratio of BOD5/Ptotal is 30-36. The paper gives the results of the tests on P-removal from wastewater carried out in a laboratory model. During investigations wastewater was flowing via mineral filters (filtralite P (FLP), zeolite (CE), and shulgite (SG)). Total amount of Ca, Fe and Al oxides contained in those filters were 23.0, 16.1 and 7.9% respectively. The rates of P-removal from wastewater in the filters were as follows: 88.5% (FLP), 45.5% (CE), and 96.3% (SG). Considering different hydraulic load, P-mass balance was calculated. The calculation results showed the following P absorption amounts: FLP - 5.08 g dE-1, CE - 1.76 g dE-1, and SG - 3.91 g dE-1 (calculated for 1 m**3 of each filter). Wastewater filtration through mineral media resulted in the removal of other pollutants, too: organic pollutants removal (according to BOD5) was 30.8 to 72.5%, and the removal of nitrogen compounds (more than 90% of which were in the form of ammonium salts) was even 93.2% in CE filter.
اظهر المزيد [+] اقل [-]