MECHANICAL SHOCK RESISTANCE OF THREADED FASTENERS
1966
Braden, John R. | Heise, Jr, Richard E.
An investigation was made of the mechanical shock resistance of K- Monel full-body studs set in HY-80 steel under various conditions. Strain gages mounted on the stud shanks were used to measure dynamic loading. Elastic nylon- insert monel stop nuts were used throughout the test. The data indicated that for the conditions of the test Locktite-coated 3A-3B threads are equal in shock resistance to uncoated 5A-5B threads, and that the elastic stop nuts are reusable after repeated shock.