Evaluation of Energy Performance of Pms Added Polyurethane in Building Heat İnsulation
2019
USTAOĞLU, Abid | KURTOĞLU, Kübra | YARAŞ, Ali
In this study, two types of insulation materials with different heat transfer coefficients were compared in a building energy performance.Within this comparison, changes in the thermal performance of the building have been examined. The conductive heat transfer coefficient ofthe polyurethane foam material is 0.02094 W/m.K and the commercial one is 0.035 W/m.K. Within the scope of the analysis, depending onthe building material, the thickness of the insulation material was changed at certain rates for both cases. With the aid of EES (EngineeringEquations Solver) program, changes in the total energy and fuel costs have been observed. In addition, the analyzes were carried out for Ankararegion having continental climate. A sample building with the same dimensions was taken as a reference in the analysis for both cases. As aresult of the analyzes, it has been observed that PMS added polyurethane foam shows a better performance of about 3.86% compare to thecommercial one in terms of energy saving.
Show more [+] Less [-]AGROVOC Keywords
Bibliographic information
This bibliographic record has been provided by Anatolia Academy of Sciences Ltd.