Evaluation of metoclopramide hydrochloride as an aid for passage of a flexible endoscope into the duodenum of dogs.
1992
Monroe W.E. | Leib M.S. | Matz M.E. | Davenport D.J. | Nelson L.P. | Kenny J.E.
The purposes of this study were to evaluate the efficacy of metoclopramide to aid passage of a flexible endoscope into the duodenum of dogs, and to determine whether the effect of metoclopramide is dependent on dose. In a randomized, blinded, complete-block design, 6 healthy dogs were anesthetized, then each was given saline solution or 1 of 4 doses of metoclopramide on different days. The ease of passage of a flexible, fiberoptic gastroscope through the pylorus was assessed independently by 3 endoscopists. Administration of metoclopramide hydrochloride at a dosage of 0.4 mg/kg of body weight, IV, made passage of a flexible endoscope into the duodenum significantly (P = 0.009) more difficult than when saline solution was administered; however, dosages of 0.1, 0.2 and 0.8 mg of metoclopramide/kg did not (P = 0.489, 0.842, and 0.092 respectively). It was concluded that metoclopramide did not facilitate, and at one dosage hindered, successful passage of a flexible endoscope into the duodenum of healthy dogs under the conditions of the study. Metoclopramide, therefore, cannot be recommended as an aid for passage of a flexible endoscope into the duodenum of dogs.
Show more [+] Less [-]AGROVOC Keywords
Bibliographic information
This bibliographic record has been provided by Wolters Kluwer