Microbiological benefits of removing foam formed after UV-enhanced ozonation of poultry-processing chiller water for recycling
2002
Diaz, M.E. | Law, S.E. | Birt, D.M.
Prior experiments using 250 mL samples of unscreened poultry overflow chiller water evaluated the beneficial bactericidal and oxidative effects of 4 different treatments (namely, O2/O3, O2/UV, O2/O3/UV, and O2 as the control) for improving microbiological safety, turbidity, and water-use efficiency allowing its reconditioning for reuse. When excluding foam as in this present study, synergistic reductions > 1.5 log CFU/mL for aerobic plate counts (APC) were additionally achieved after 4 min for all O3/UV treatment combinations as compared to serially applied treatments of O3 and UV acting separately. With foam present, 16-min O3/UV treatments were required to achieve similar results. We now report these additional benefits achieved by removing the foam formed by the advanced oxidation process of ultraviolet-photon enhanced ozonation. Furthermore, foam microbial and general physical content were analyzed to determine suitability as an additive in rendering-type processes. Treatment of the wastewater resulted in total plate counts between 2 to 4 Log CFU/mL in the foam after 8 min. Fat and protein constituted 89% of the solids collected (384 mg/L or 14% of the foam) with trace amounts of metal elements (for example, Ca, Na, K, Fe, Cu) present. Irradiating had negligible effect on foam characteristics yet decreased the amount of solids collected.
Show more [+] Less [-]AGROVOC Keywords
Bibliographic information
This bibliographic record has been provided by National Agricultural Library