A model for performance of sulfite oxidation of ammonia-based flue gas desulfurization system
2015
Jia, Yong | Yin, Liguo | Xu, Yalin | Ding, Xilou | Sheng, Guanghong
A mathematical model was developed to simulate the oxidation of total sulfite in the holding tank of ammonia-based flue gas desulfurization (FGD) system. The model could provide predictions of the oxidation ratio of total sulfite at different operating condition such as pH, concentration of total sulfur, air flow and residence time. The calculation results of an ammonia-based FGD system for 2 × 150 MW boilers by this model were compared to that of corresponding measured values. The comparison results show that the simulated oxidation ratio of total sulfite agrees well with the measured data. The difference between calculated values and measured data is below 4.2%. This model appears to be beneficial for optimizing design and operation of total sulfite oxidation of an ammonia-based FGD system.
Show more [+] Less [-]AGROVOC Keywords
Bibliographic information
This bibliographic record has been provided by National Agricultural Library