Development of an enzyme-linked immunosorbent assay for atrazine monitoring in water samples
2013 | 1000
Lima, D. L. D. | Schneider, R. J. | Esteves, V. I.
The implementation of the Water Framework Directive (2000/60/EC) requires the establishment of monitoring programs. However, conventional procedures for sample preparation prior to chromatographic analysis are rather expensive and time consuming, being the development of cost-effective and easy tool a necessity. The aim of this work was to develop an enzyme-linked immunosorbent assay (ELISA) able to determine atrazine in water samples. Matrix effects evaluation showed that the increase of humic acid (HA) concentration leads to flattened calibration curves and to the loss of the sigmoidal shape. However, such interference was overcome, by the presence of an environmental sample buffer, incubated together with the samples. Recoveries from 88.5 to 119.2 % were obtained in the presence of HA concentrations up to 20 mgL−1 . An analytical range from 0.003 to 1 μgL−1 was obtained, and atrazine was detected in a sewage treatment plant with concentrations ranging from 14 to 52 ngL−1.
Show more [+] Less [-]AGROVOC Keywords
Bibliographic information
This bibliographic record has been provided by Universidade de Aveiro