Refine search
Results 41-50 of 95
Microcontact printing of proteins for cell biology Full text
2008
Shen, Keyue | Qi, Jie | Kam, Lance C.
The ability to pattern proteins and other biomolecules onto substrates is important for capturing the spatial complexity of the extracellular environment. Development of microcontact printing by the Whitesides group (http://gmwgroup.harvard.edu/) in the mid-1990s revolutionalized this field by making microelectronics/microfabrication techniques accessible to laboratories focused on the life sciences. Initial implementations of this method used polydimethylsiloxane (PDMS) stamps to create patterns of functionalized chemicals on material surfaces1. Since then, a range of innovative approaches have been developed to pattern other molecules, including proteins2. This video demonstrates the basic process of creating PDMS stamps and uses them to pattern proteins, as these steps are difficult to accurately express in words. We focus on patterning the extracellular matrix protein fibronectin onto glass coverslips as a specific example of patterning. An important component of the microcontact printing process is a topological master, from which the stamps are cast; the raised and lowered regions of the master are mirrored into the stamp and define the final pattern. Typically, a master consists of a silicon wafer coated with photoresist and then patterned by photolithography, as is done here. Creation of masters containing a specific pattern requires specialized equipment, and is best approached in consultation with a fabrication center or facility. However, almost any substrate with topology can be used as a master, such as plastic diffraction gratings (see Reagents for one example), and such serendipitous masters provide readily available, simple patterns. This protocol begins at the point of having a master in hand.
Show more [+] Less [-]Labeling hescs and hmscs with iron oxide nanoparticles for non-invasive in vivo tracking with mr imaging Full text
2008
Henning, Tobias D. | Boddington, Sophie | Daldrup-Link, Heike E.
In recent years, stem cell research has led to a better understanding of developmental biology, various diseases and its potential impact on regenerative medicine. A non-invasive method to monitor the transplanted stem cells repeatedly in vivo would greatly enhance our ability to understand the mechanisms that control stem cell death and identify trophic factors and signaling pathways that improve stem cell engraftment. MR imaging has been proven to be an effective tool for the in vivo depiction of stem cells with near microscopic anatomical resolution. In order to detect stem cells with MR, the cells have to be labeled with cell specific MR contrast agents. For this purpose, iron oxide nanoparticles, such as superparamagnetic iron oxide particles (SPIO), are applied, because of their high sensitivity for cell detection and their excellent biocompatibility. SPIO particles are composed of an iron oxide core and a dextran, carboxydextran or starch coat, and function by creating local field inhomogeneities, that cause a decreased signal on T2-weighted MR images. This presentation will demonstrate techniques for labeling of stem cells with clinically applicable MR contrast agents for subsequent non-invasive in vivo tracking of the labeled cells with MR imaging.
Show more [+] Less [-]In vitro differentiation of mouse embryonic stem (mes) cells using the hanging drop method Full text
2008
Wang, Xiang | Yang, Phillip
Stem cells have the remarkable potential to develop into many different cell types. When a stem cell divides, each new cell has the potential to either remain a stem cell or become another type of cell with a more specialized function, This promising of science is leading scientists to investigate the possibility of cell-based therapies to treat disease. When culture in suspension without antidifferentiation factors, embryonic stem cells spontaneously differentiate and form three-dimensional multicellular aggregates. These cell aggregates are called embryoid bodies(EB). Hanging drop culture is a widely used EB formation induction method. The rounded bottom of hanging drop allows the aggregation of ES cells which can provide mES cells a good environment for forming EBs. The number of ES cells aggregatied in a hanging drop can be controlled by varying the number of cells in the initial cell suspension to be hung as a drop from the lid of Petri dish. Using this method we can reproducibly form homogeneous EBs from a predetermined number of ES cells.
Show more [+] Less [-]Obtaining eggs from xenopus laevis females Full text
2008
Cross, Marie K. | Powers, Maureen
The eggs of Xenopus laevis intact, lysed, and/or fractionated are useful for a wide variety of experiments. This protocol shows how to induce egg laying, collect and dejelly the eggs, and sort the eggs to remove any damaged eggs.
Show more [+] Less [-]Pyrosequencing: a simple method for accurate genotyping Full text
2008
King, Cristi | Scott-Horton, Tiffany
Pharmacogenetic research benefits first-hand from the abundance of information provided by the completion of the Human Genome Project. With such a tremendous amount of data available comes an explosion of genotyping methods. Pyrosequencing(R) is one of the most thorough yet simple methods to date used to analyze polymorphisms. It also has the ability to identify tri-allelic, indels, short-repeat polymorphisms, along with determining allele percentages for methylation or pooled sample assessment. In addition, there is a standardized control sequence that provides internal quality control. This method has led to rapid and efficient single-nucleotide polymorphism evaluation including many clinically relevant polymorphisms. The technique and methodology of Pyrosequencing is explained.
Show more [+] Less [-]Staining proteins in gels Full text
2008
Gallagher, Sean | Chakavarti, Deb
Following separation by electrophoretic methods, proteins in a gel can be detected by several staining methods. This unit describes protocols for detecting proteins by four popular methods. Coomassie blue staining is an easy and rapid method. Silver staining, while more time consuming, is considerably more sensitive and can thus be used to detect smaller amounts of protein. Fluorescent staining is a popular alternative to traditional staining procedures, mainly because it is more sensitive than Coomassie staining, and is often as sensitive as silver staining. Staining of proteins with SYPRO Orange and SYPRO Ruby are also demonstrated here.
Show more [+] Less [-]Microfluidic applications for disposable diagnostics Full text
2008
Klapperich, Catherine
In this interview, Dr. Klapperich discusses the fabrication of thermoplastic microfluidic devices and their application for development of new diagnostics.
Show more [+] Less [-]Screening for amyloid aggregation by semi-denaturing detergent-agarose gel electrophoresis Full text
2008
Halfmann, Randal | Lindquist, Susan
Amyloid aggregation is associated with numerous protein misfolding pathologies and underlies the infectious properties of prions, which are conformationally self-templating proteins that are thought to have beneficial roles in lower organisms. Amyloids have been notoriously difficult to study due to their insolubility and structural heterogeneity. However, resolution of amyloid polymers based on size and detergent insolubility has been made possible by Semi-Denaturing Detergent-Agarose Gel Electrophoresis (SDD-AGE). This technique is finding widespread use for the detection and characterization of amyloid conformational variants. Here, we demonstrate an adaptation of this technique that facilitates its use in large-scale applications, such as screens for novel prions and other amyloidogenic proteins. The new SDD-AGE method uses capillary transfer for greater reliability and ease of use, and allows any sized gel to be accomodated. Thus, a large number of samples, prepared from cells or purified proteins, can be processed simultaneously for the presence of SDS-insoluble conformers of tagged proteins.
Show more [+] Less [-]Retrograde labeling of retinal ganglion cells by application of fluoro-gold on the surface of superior colliculus Full text
2008
Chiu, Kin | Lau, Wui-Man | Yeung, Sze-chun | Chang, Raymond Chuen-Chung | So, Kwok-Fai
Retinal ganglion cell (RGC) counting is essential to evaluate retinal degeneration especially in glaucoma. Reliable RGC labeling is fundamental for evaluating the effects of any treatment. In rat, about 98% of RGCs is known to project to the contralateral superior colliculus (SC) (Forrester and Peters, 1967). Applying fluoro-gold (FG) on the surface of SC can label almost all the RGCs, so that we can focus on this most vulnerable retinal neuron in glaucoma. FG is taken up by the axon terminals of retinal ganglion cells and bilaterally transported retrogradely to its somas in the retina. Compare with retrograde labeling of RGC by putting FG at stump of transected optic nerve for 2 days, the interference of RGC survival is minimized. Compare with cresyl violet staining that stains RGCs, amacrine cells and endothelium of the blood vessel in the retinal ganglion cell layer, this labeling method is more specific to the RGC. This video describes the method of retrograde labeling of RGC by applying FG on the surface of SC. The surgical procedures include drilling the skull; aspirating the cortex to expose the SC and applying gelatin sponge over entire dorsal surface of SC are shown. Useful tips for avoiding massive intracranial bleeding and aspiration of the SC have been given.
Show more [+] Less [-]Operant learning of drosophila at the torque meter Full text
2008
Brembs, Bjoern
For experiments at the torque meter, flies are kept on standard fly medium at 25°C and 60% humidity with a 12hr light/12hr dark regime. A standardized breeding regime assures proper larval density and age-matched cohorts. Cold-anesthetized flies are glued with head and thorax to a triangle-shaped hook the day before the experiment. Attached to the torque meter via a clamp, the fly's intended flight maneuvers are measured as the angular momentum around its vertical body axis. The fly is placed in the center of a cylindrical panorama to accomplish stationary flight. An analog to digital converter card feeds the yaw torque signal into a computer which stores the trace for later analysis. The computer also controls a variety of stimuli which can be brought under the fly's control by closing the feedback loop between these stimuli and the yaw torque trace. Punishment is achieved by applying heat from an adjustable infrared laser.
Show more [+] Less [-]