Refine search
Results 71-80 of 512
Spinal cord electrophysiology ii: extracellular suction electrode fabrication Full text
2011
Garudadri, Suresh | Gallarda, Benjamin | Pfaff, Samuel | Alaynick, William
Development of neural circuitries and locomotion can be studied using neonatal rodent spinal cord central pattern generator (CPG) behavior. We demonstrate a method to fabricate suction electrodes that are used to examine CPG activity, or fictive locomotion, in dissected rodent spinal cords. The rodent spinal cords are placed in artificial cerebrospinal fluid and the ventral roots are drawn into the suction electrode. The electrode is constructed by modifying a commercially available suction electrode. A heavier silver wire is used instead of the standard wire given by the commercially available electrode. The glass tip on the commercial electrode is replaced with a plastic tip for increased durability. We prepare hand drawn electrodes and electrodes made from specific sizes of tubing, allowing consistency and reproducibility. Data is collected using an amplifier and neurogram acquisition software. Recordings are performed on an air table within a Faraday cage to prevent mechanical and electrical interference, respectively.
Show more [+] Less [-]A simple and efficient method to isolate macrophages from mixed primary cultures of adult liver cells Full text
2011
Kitani, Hiroshi | Takenouchi, Takato | Sato, Mitsuru | Yoshioka, Miyako | Yamanaka, Noriko
Kupffer cells are liver-specific resident macrophages and play an important role in the physiological and pathological functions of the liver1-3. Although the isolation methods of liver macrophages have been well-described4-6, most of these methods require sophisticated equipment, such as a centrifugal elutriator and technical skills. Here, we provide a novel method to obtain liver macrophages in sufficient number and purity from mixed primary cultures of adult rat liver cells, as schematically illustrated in Figure 1. After dissociation of the liver cells by two-step perfusion method7,8,a fraction mostly composed of parenchymal hepatocytes is prepared and seeded into T75 tissue culture flasks with culture medium composed of DMEM and 10% FCS.Parenchymal hepatocytes lose the epithelial cell morphology within a few days in culture, degenerate or transform into fibroblast-like cells (Figure 2). As the culture proceeds, around day 6, phase contrast-bright, round macrophage-like cells start to proliferate on the fibroblastic cell sheet (Figure 2). The growth of the macrophage-like cells continue and reach to maximum levels around day 12, covering the cell sheet on the flask surface. By shaking of the culture flasks, macrophages are readily suspended into the culture medium. Subsequent transfer and short incubation in plastic dishes result in selective adhesion of macrophages(Figure 3), where as other contaminating cells remain suspended. After several rinses with PBS, attached macrophages are harvested. More than 106 cells can be harvested repeatedly from the same T75 tissue culture flask at two to three day intervals for more than two weeks(Figure 3).The purities of the isolated macrophages were 95 to 99%, as evaluated by flow cytometry or immunocytochemistry with rat macrophage-specific antibodies (Figure 4).The isolated cells show active phagocytosis of polystylene beads (Figure 5), proliferative response to recombinant GM-CSF, secretion of inflammatory/anti-inflammatory cytokines upon stimulation with LPS, and formation of multinucleated giant cells9. In conclusion, we provide a simple and efficient method to obtain liver macrophages in sufficient number and purity without complex equipment and skills.This method might be applicable to other mammalian species.
Show more [+] Less [-]Constructing a low-budget laser axotomy system to study axon regeneration in C. elegans Full text
2011
Williams, Wes | Nix, Paola | Bastiani, Michael
Laser axotomy followed by time-lapse microscopy is a sensitive assay for axon regeneration phenotypes in C. elegans1. The main difficulty of this assay is the perceived cost ($25-100K) and technical expertise required for implementing a laser ablation system2,3. However, solid-state pulse lasers of modest costs (<$10K) can provide robust performance for laser ablation in transparent preparations where target axons are "close" to the tissue surface. Construction and alignment of a system can be accomplished in a day. The optical path provided by light from the focused condenser to the ablation laser provides a convenient alignment guide. An intermediate module with all optics removed can be dedicated to the ablation laser and assures that no optical elements need be moved during a laser ablation session. A dichroic in the intermediate module allows simultaneous imaging and laser ablation. Centering the laser beam to the outgoing beam from the focused microscope condenser lens guides the initial alignment of the system. A variety of lenses are used to condition and expand the laser beam to fill the back aperture of the chosen objective lens. Final alignment and testing is performed with a front surface mirrored glass slide target. Laser power is adjusted to give a minimum size ablation spot (<1um). The ablation spot is centered with fine adjustments of the last kinematically mounted mirror to cross hairs fixed in the imaging window. Laser power for axotomy will be approximately 10X higher than needed for the minimum ablation spot on the target slide (this may vary with the target you use). Worms can be immobilized for laser axotomy and time-lapse imaging by mounting on agarose pads (or in microfluidic chambers4). Agarose pads are easily made with 10% agarose in balanced saline melted in a microwave. A drop of molten agarose is placed on a glass slide and flattened with another glass slide into a pad approximately 200 um thick (a single layer of time tape on adjacent slides is used as a spacer). A "Sharpie" cap is used to cut out a uniformed diameter circular pad of 13mm. Anesthetic (1ul Muscimol 20mM) and Microspheres (Chris Fang-Yen personal communication) (1ul 2.65% Polystyrene 0.1 um in water) are added to the center of the pad followed by 3-5 worms oriented so they are lying on their left sides. A glass coverslip is applied and then Vaseline is used to seal the coverslip and prevent evaporation of the sample.
Show more [+] Less [-]Stretching short sequences of dna with constant force axial optical tweezers Full text
2011
Raghunathan, Krishnan | Milstein, Joshua N. | Meiners, Jens -Christian
Single-molecule techniques for stretching DNA of contour lengths less than a kilobase are fraught with experimental difficulties. However, many interesting biological events such as histone binding and protein-mediated looping of DNA1,2, occur on this length scale. In recent years, the mechanical properties of DNA have been shown to play a significant role in fundamental cellular processes like the packaging of DNA into compact nucleosomes and chromatin fibers3,4. Clearly, it is then important to understand the mechanical properties of short stretches of DNA. In this paper, we provide a practical guide to a single-molecule optical tweezing technique that we have developed to study the mechanical behavior of DNA with contour lengths as short as a few hundred basepairs. The major hurdle in stretching short segments of DNA is that conventional optical tweezers are generally designed to apply force in a direction lateral to the stage5,6, (see Fig. 1). In this geometry, the angle between the bead and the coverslip, to which the DNA is tethered, becomes very steep for submicron length DNA. The axial position must now be accounted for, which can be a challenge, and, since the extension drags the microsphere closer to the coverslip, steric effects are enhanced. Furthermore, as a result of the asymmetry of the microspheres, lateral extensions will generate varying levels of torque due to rotation of the microsphere within the optical trap since the direction of the reactive force changes during the extension. Alternate methods for stretching submicron DNA run up against their own unique hurdles. For instance, a dual-beam optical trap is limited to stretching DNA of around a wavelength, at which point interference effects between the two traps and from light scattering between the microspheres begin to pose a significant problem. Replacing one of the traps with a micropipette would most likely suffer from similar challenges. While one could directly use the axial potential to stretch the DNA, an active feedback scheme would be needed to apply a constant force and the bandwidth of this will be quite limited, especially at low forces. We circumvent these fundamental problems by directly pulling the DNA away from the coverslip by using a constant force axial optical tweezers7,8. This is achieved by trapping the bead in a linear region of the optical potential, where the optical force is constant-the strength of which can be tuned by adjusting the laser power. Trapping within the linear region also serves as an all optical force-clamp on the DNA that extends for nearly 350 nm in the axial direction. We simultaneously compensate for thermal and mechanical drift by finely adjusting the position of the stage so that a reference microsphere stuck to the coverslip remains at the same position and focus, allowing for a virtually limitless observation period.
Show more [+] Less [-]Scale-up of mammalian cell culture using a new multilayered flask Full text
2011
Abraham, Elizabeth J. | Slater, Katie A. | Sanyal, Suparna | Linehan, Ken | Flaherty, Paula M. | Qian, Susan
A growing number of cell-based applications require large numbers of cells. Usage of single layer T-flasks, that are adequate during small-scale expansion, may become cumbersome, laborious and time-consuming when large numbers of cells are required. To address this need, the performance of a new multi-layered cell culture vessel to facilitate easy scale up of cells from single layered T-flasks will be discussed. The flasks tested are available in 3- and 5-layer format and enable culture and complete recovery of three and five times the number of cells respectively, compared to T-175 flasks. A key feature of the BD Multi-Flask is a mix/equilibration port that allows rapid in-vessel mixing as well as uniform distribution of cells and reagents within and between layers of each vessel and consistently produce cells that can be cultured in an environment that is congruent to T-175 flasks. The design of these Multi-Flasks also allows for convenient pipette access for adding reagents and cells directly into the flasks as well as efficient recovery of valuable cells and reagents and reduces risk of contamination due to pouring. For applications where pouring is preferred over pipetting, the design allows for minimal residual liquid retention so as to reduce wastage of valuable cells and reagents.
Show more [+] Less [-]Establishment and propagation of human retinoblastoma tumors in immune deficient mice Full text
2011
Bond, Wesley S. | Wadhwa, Lalita | Perlaky, Laszlo | Penland, Rebecca L. | Hurwitz, Mary Y. | Hurwitz, Richard L. | Chévez-Barrios, Patricia
Culturing retinoblastoma tumor cells in defined stem cell media gives rise to primary tumorspheres that can be grown and maintained for only a limited time. These cultured tumorspheres may exhibit markedly different cellular phenotypes when compared to the original tumors. Demonstration that cultured cells have the capability of forming new tumors is important to ensure that cultured cells model the biology of the original tumor. Here we present a protocol for propagating human retinoblastoma tumors in vivo using Rag2-/- immune deficient mice. Cultured human retinoblastoma tumorspheres of low passage or cells obtained from freshly harvested human retinoblastoma tumors injected directly into the vitreous cavity of murine eyes form tumors within 2-4 weeks. These tumors can be harvested and either further passaged into murine eyes in vivo or grown as tumorspheres in vitro. Propagation has been successfully carried out for at least three passages thus establishing a continuing source of human retinoblastoma tissue for further experimentation. Wesley S. Bond and Lalita Wadhwa are co-first authors.
Show more [+] Less [-]Engineering biological-based vascular grafts using a pulsatile bioreactor Full text
2011
Huang, Angela H. | Niklason, Laura E.
Much effort has been devoted to develop and advance the methodology to regenerate functional small-diameter arterial bypasses. In the physiological environment, both mechanical and chemical stimulation are required to maintain the proper development and functionality of arterial vessels1,2. Bioreactor culture systems developed by our group are designed to support vessel regeneration within a precisely controlled chemo-mechanical environment mimicking that of native vessels. Our bioreactor assembly and maintenance procedures are fairly simple and highly repeatable3,4. Smooth muscle cells (SMCs) are seeded onto a tubular polyglycolic acid (PGA) mesh that is threaded over compliant silicone tubing and cultured in the bioreactor with or without pulsatile stimulation for up to 12 weeks. There are four main attributes that distinguish our bioreactor from some predecessors. 1) Unlike other culture systems that simulate only the biochemical surrounding of native blood vessels, our bioreactor also creates a physiological pulsatile environment by applying cyclic radial strain to the vessels in culture. 2) Multiple engineered vessels can be cultured simultaneously under different mechanical conditions within a controlled chemical environment. 3) The bioreactor allows a mono layer of endothelial cells (EC) to be easily coated onto the luminal side of engineered vessels for animal implantation models. 4) Our bioreactor can also culture engineered vessels with different diameter size ranged from 1 mm to 3 mm, saving the effort to tailor each individual bioreactor to fit a specific diameter size. The engineered vessels cultured in our bioreactor resemble native blood vessels histologically to some degree. Cells in the vessel walls express mature SMC contractile markers such as smooth muscle myosin heavy chain (SMMHC)3. A substantial amount of collagen is deposited within the extracellular matrix, which is responsible for ultimate mechanical strength of the engineered vessels5. Biochemical analysis also indicates that collagen content of engineered vessels is comparable to that of native arteries6. Importantly, the pulsatile bioreactor has consistently regenerated vessels that exhibit mechanical properties that permit successful implantation experiments in animal models3,7. Additionally, this bioreactor can be further modified to allow real-time assessment and tracking of collagen remodeling over time, non-invasively, using a non-linear optical microscopy (NLOM)8. To conclude, this bioreactor should serve as an excellent platform to study the fundamental mechanisms that regulate the regeneration of functional small-diameter vascular grafts.
Show more [+] Less [-]A procedure for studying the footshock-induced reinstatement of cocaine seeking in laboratory rats Full text
2011
Kupferschmidt, David A. | Brown, Zenya J. | Erb, Suzanne
The most insidious aspect of drug addiction is the high propensity for relapse. Animal models of relapse, known as reinstatement procedures, have been used extensively to study the neurobiology and phenomenology of relapse to drug use. Although procedural variations have emerged over the past several decades, the most conventional reinstatement procedures are based on the drug self-administration (SA) model. In this model, an animal is trained to perform an operant response to obtain drug. Subsequently, the behavior is extinguished by withholding response-contingent reinforcement. Reinstatement of drug seeking is then triggered by a discrete event, such as an injection of the training drug, re-exposure to drug-associated cues, or exposure to a stressor 1. Reinstatement procedures were originally developed to study the ability of acute non-contingent exposure to the training drug to reinstate drug seeking in rats and monkeys 1, 2. Reinstatement procedures have since been modified to study the role of environmental stimuli, including drug-associated cues and exposure to various forms of stress, in relapse to drug seeking 1, 3, 4. Over the past 15 years, a major focus of the reinstatement literature has been on the role of stress in drug relapse. One of the most commonly used forms of stress for studying this relationship is acute exposures to mild, intermittent, electric footshocks. The ability of footshock stress to induce reinstatement of drug seeking was originally demonstrated by Shaham and colleagues (1995) in rats with a history of intravenous heroin SA5. Subsequently, the effect was generalized to rats with histories of intravenous cocaine, methamphetamine, and nicotine SA, as well as oral ethanol SA 3, 6. Although footshock-induced reinstatement of drug seeking can be achieved reliably and robustly, it is an effect that tends to be sensitive to certain parametrical variables. These include the arrangement of extinction and reinstatement test sessions, the intensity and duration of footshock stress, and the presence of drug-associated cues during extinction and testing for reinstatement. Here we present a protocol for footshock-induced reinstatement of cocaine seeking that we have used with consistent success to study the relationship between stress and cocaine seeking.
Show more [+] Less [-]A protocol for computer-based protein structure and function prediction Full text
2011
Roy, Ambrish | Xu, Dong | Poisson, Jonathan | Zhang, Yang
Genome sequencing projects have ciphered millions of protein sequence, which require knowledge of their structure and function to improve the understanding of their biological role. Although experimental methods can provide detailed information for a small fraction of these proteins, computational modeling is needed for the majority of protein molecules which are experimentally uncharacterized. The I-TASSER server is an on-line workbench for high-resolution modeling of protein structure and function. Given a protein sequence, a typical output from the I-TASSER server includes secondary structure prediction, predicted solvent accessibility of each residue, homologous template proteins detected by threading and structure alignments, up to five full-length tertiary structural models, and structure-based functional annotations for enzyme classification, Gene Ontology terms and protein-ligand binding sites. All the predictions are tagged with a confidence score which tells how accurate the predictions are without knowing the experimental data. To facilitate the special requests of end users, the server provides channels to accept user-specified inter-residue distance and contact maps to interactively change the I-TASSER modeling; it also allows users to specify any proteins as template, or to exclude any template proteins during the structure assembly simulations. The structural information could be collected by the users based on experimental evidences or biological insights with the purpose of improving the quality of I-TASSER predictions. The server was evaluated as the best programs for protein structure and function predictions in the recent community-wide CASP experiments. There are currently >20,000 registered scientists from over 100 countries who are using the on-line I-TASSER server.
Show more [+] Less [-]Procedures for rat in situ skeletal muscle contractile properties Full text
2011
MacIntosh, Brian R. | Esau, Shane P. | Holash, R John | Fletcher, Jared R.
There are many circumstances where it is desirable to obtain the contractile response of skeletal muscle under physiological circumstances: normal circulation, intact whole muscle, at body temperature. This includes the study of contractile responses like posttetanic potentiation, staircase and fatigue. Furthermore, the consequences of disease, disuse, injury, training and drug treatment can be of interest. This video demonstrates appropriate procedures to set up and use this valuable muscle preparation. To set up this preparation, the animal must be anesthetized, and the medial gastrocnemius muscle is surgically isolated, with the origin intact. Care must be taken to maintain the blood and nerve supplies. A long section of the sciatic nerve is cleared of connective tissue, and severed proximally. All branches of the distal stump that do not innervate the medial gastrocnemius muscle are severed. The distal nerve stump is inserted into a cuff lined with stainless steel stimulating wires. The calcaneus is severed, leaving a small piece of bone still attached to the Achilles tendon. Sonometric crystals and/or electrodes for electromyography can be inserted. Immobilization by metal probes in the femur and tibia prevents movement of the muscle origin. The Achilles tendon is attached to the force transducer and the loosened skin is pulled up at the sides to form a container that is filled with warmed paraffin oil. The oil distributes heat evenly and minimizes evaporative heat loss. A heat lamp is directed on the muscle, and the muscle and rat are allowed to warm up to 37°C. While it is warming, maximal voltage and optimal length can be determined. These are important initial conditions for any experiment on intact whole muscle. The experiment may include determination of standard contractile properties, like the force-frequency relationship, force-length relationship, and force-velocity relationship. With care in surgical isolation, immobilization of the origin of the muscle and alignment of the muscle-tendon unit with the force transducer, and proper data analysis, high quality measurements can be obtained with this muscle preparation.
Show more [+] Less [-]