Refine search
Results 1-3 of 3
Evaluation of isoflurane and sevoflurane vaporizers over a wide range of oxygen flow rates
2006
Ambrisko, T.D. | Klide, A.M.
Objective-To examine the accuracy and precision of isoflurane and sevoflurane anesthetic vaporizers. Sample Population-5 identcal isoflurane and 5 identical sevoflurane vaporizers. Procedures-Oxygen flow rates from 0.02 to 10 L/min were used with different vaporizer dial settings. Agent concentrations were measured at the common gas outlet by use of a refractometer. Accuracy was defined as the difference between measured agent concentrations, and dial settings were expressed as a percentage of the applied dial settings. Precision was defined as SD of the measured agent concentrations for each combination of dial setting and flow. Results-Isoflurane values were generally greater than the dial settings. Accuracy of the isoflurane vaporizer was > 20% when 0.6% and 1% was dialed. Accuracy of the sevoflurane vaporizer was always within +/- 20% but decreased at 0.02 L/min flow and at combinations of high flow and high dial settings. Overall precision of the isoflurane vaporizer was better than that of the sevoflurane vaporizer. Conclusions and Clinical Relevance-A possible explanation for the inaccuracy of the isoflurane vaporizer may be that it was manufactured to be accurate with air but not oxygen, which must be accounted for when using the vaporizer with oxygen, especially with nonrebreathing systems. The sevoflurane vaporizer may not deliver accurate agent concentrations at high flow and high dial settings. Both vaporizers are suitable for clinical use with a wide range of oxygen flow rates if these precautions are properly addressed.
Show more [+] Less [-]Oral administration of sucrose solutions and measurement of serum sucrose concentrations to evaluate gastric permeability in adult bottlenose dolphins (Tursiops truncatus)
2006
Buddington, K.K. | Holmes, W.E. | Clemons-Chevis, C.L. | Solangi, M.A. | Vanderpool, D. | Buddington, R.K.
Objective-To measure concentrations of sucrose in the serum of captive dolphins after oral administration of a sucrose solution and determine the suitability of this method for use as a test to detect gastric ulcers. Animals-8 adult captive bottlenose dolphins (Tursiops truncatus). Procedures-Blood samples were collected from the ventral fluke vein of dolphins before and 45 minutes after oral administration of 500 mL of solution containing 25 or 50 g of sucrose; oral administration was achieved by use of gastric intubation. Serum was separated, diluted in a solution of 90% acetonitrile-to-10% water that contained 10 ng of an internal standard (trichlormethiazide)/microliter, mixed, and centrifuged. Supernatant was analyzed by use of liquid chromatography-mass spectrometry-mass spectrometry (LC-MS-MS). Results-Serum sucrose concentrations of dolphins were at or less than the limits of detection before oral administration. Values after administration of sucrose solution varied among dolphins and were higher and more variable after administration of 50 g, compared with concentrations after administration of 25 g. Conclusions and Clinical Relevance-Serum sucrose concentrations in samples collected during routine health evaluations of captive dolphins can be reliably measured by use of LC-MS-MS. Correlating serum sucrose concentrations with endoscopic observations of the gastric mucosa of dolphins will validate this approach for use in screening for the prevalence and severity of gastric ulcers and determining the efficacy of treatment regimens.
Show more [+] Less [-]Evaluation of assay procedures for prediction of passive transfer status in lambs
2006
Massimini, G. | Peli, A. | Boari, A. | Britti, D.
Objective-To compare 4 assay procedures for prediction of passive transfer status in lambs. Animals-Thirty-one 1-day-old Sardinian lambs. Procedure-Serum IgG concentration was determined by use of single radial immunodiffusion. The following were determined: serum total protein concentration as measured by refractometry (ie, refractometry serum total protein concentration), serum total protein concentration as determined by the biuret method (ie, biuret method serum total protein concentration), serum gamma-globulin concentration as determined by serum protein electrophoresis, and serum gamma-glutamyltransferase (GGT) activity as measured by spectrophotometry. Accuracy of these assays for estimation of serum IgG concentration in 1-day-old lambs was established by use of linear regression analysis. Results-Refractometry serum total protein concentration, biuret method serum total protein concentration, and serum gamma-globulin concentration were closely and linearly correlated with serum IgG concentration. The natural logarithm (ln) of serum GGT activity was closely and linearly correlated with serum IgG concentration (ln). Refractometry serum total protein concentration, biuret method serum total protein concentration, and gamma-globulin concentration accounted for approximately 85%, 91%, and 95% of the variation in serum IgG concentration, respectively. Serum GGT activity (ln) accounted for approximately 92% of the variation in serum IgG concentration (ln). Conclusions and Clinical Relevance-For prediction of passive transfer status in 1-day-old lambs, serum GGT activity or biuret method serum total protein concentration determination will allow for passive transfer monitoring program development. Immediate refractometry serum total protein concentration determination is beneficial in making timely management and treatment decisions. Serum gamma-globulin concentration determination can be used as a confirmatory test.
Show more [+] Less [-]