Refine search
Results 1-10 of 31
Modification of a haematoxylin, eosin, and natural saffron staining method for the detection of connective tissue
2021
Ceccopieri, Cassandra | Skonieczna, Joanna | Madej, Jan P.
The aim of our study was to optimise an existing staining procedure: haematoxylin-eosin saffron (HES). The method follows the classical haematoxylin and eosin protocol with the addition of a staining step using natural saffron to better identify the collagen fibres. The saffron solution was obtained by dissolving ground saffron stigmas in absolute alcohol. In order to test the HES method for its staining ability on four main types of collagen (I, II, III, and IV), specific tissues (skin, tooth, cartilage, aorta, spleen, and penis) were chosen. The procedure showed a sharp differentiation between muscle, stained red or pink, and connective tissue, stained bright yellow or orange. HES allows the diagnosis of reticulin fibrosis undetected in HE and in previous saffron staining procedures. HES represents an advantageous alternative to HE staining giving highly reproducible results with high diagnostic value.
Show more [+] Less [-]Influence of α-lipoic acid on morphology of organs of rabbits fed a high fat diet with the addition of oxidised rapeseed oil
2017
Stawiarska-Pięta Barbara | Zalejska-Fiolka Jolanta | Wyszyńska Magdalena | Kleczka Anna | Janiga Beata | Grzegorzak Natalia | Birkner Ewa
Introduction: The aim of the study was to assess the influence of α-lipoic acid (ALA) on the morphology of the aorta and liver of rabbits fed high fat diet with addition of oxidised (ORO) and non-oxidised rapeseed oil (N-ORO).
Show more [+] Less [-]Pilot study investigating the feasibility of mitral valve repair without aortic cross-clamping and cardioplegia
2020
Gordon-Evans, Wanda J. | Carney, John P. | Lahti, Mathew T. | Bianco, Richard W.
There is evidence that perfusing the heart with a heart and lung machine is less injurious than cross-clamping the aorta and administering cardioplegia during cardiac surgery. Although mitral valve replacement has been carried out without aortic cross-clamping and cardioplegia, it has been stated that cross-clamping is necessary in order to maintain visualization and a motionless surgical field for mitral valve repair. The purpose of this study was to determine the surgical feasibility of mitral valve repair without cross-clamping the aorta and using cardioplegia. Our hypothesis was that a completely bloodless and motion-free field would not be necessary to carry out mitral valve repair with annuloplasty and synthetic chordae tendineae sutures. Papillary muscles, chordae tendineae, annulus, and mitral valve leaflets were all readily visualized. Chordae tendineae sutures were used and annuloplasty was conducted without visual obstruction or motion interference. Our results show that mitral valve repair is feasible without cross-clamping the aorta and using cardioplegia.
Show more [+] Less [-]Correlation of the ratio of caudal vena cava diameter and aorta diameter with systolic pressure variation in anesthetized dogs
2016
Meneghini, Caterina | Rabozzi, Roberto | Franci, Paolo
OBJECTIVE To evaluate the correlation coefficient of the ratio between diameter of the caudal vena cava (CVC) and diameter of the aorta (Ao) in dogs as determined ultrasonographically with systolic pressure variation (SPV). ANIMALS 14 client-owned dogs (9 females and 5 males; mean ± SD age, 73 ± 40 months; mean body weight, 22 ± 7 kg) that underwent anesthesia for repair of skin wounds. PROCEDURES Anesthesia was induced. Controlled mechanical ventilation with a peak inspiratory pressure of 8 cm H2O was immediately started, and SPV was measured. During a brief period of suspension of ventilation, CVC-to-Ao ratio was measured on a transverse right-lateral intercostal ultrasonographic image obtained at the level of the porta hepatis. When the SPV was ≥ 4 mm Hg, at least 1 bolus (3 to 4 mL/kg) of Hartmann solution was administered IV during a 1-minute period. Bolus administration was stopped and the CVC-to-Ao ratio measured when SPV was < 4 mm Hg. Correlation coefficient analysis was performed. RESULTS 28 measurements were obtained. The correlation coefficient was 0.86 (95% confidence interval, 0.72 to 0.93). Mean ± SD SPV and CVC-to-Ao ratio before bolus administration were 7 ± 2 mm Hg and 0.52 ± 0.16, respectively. Mean ± SD SPV and CVC-to-Ao ratio after bolus administration were 2 ± 0.6 mm Hg and 0.91 ± 0.13, respectively. CONCLUSIONS AND CLINICAL RELEVANCE In this study, the CVC-to-Ao ratio was a feasible, noninvasive ultrasonographically determined value that correlated well with SPV.
Show more [+] Less [-]Dynamic computed tomographic determination of scan delay for use in performing cardiac angiography in clinically normal dogs
2015
Kim, Jisun | Bae, Yeonho | Lee, Gahyun | Jeon, Sunghoon | Choi, Jihye
OBJECTIVE To determine the scan delay for use in performing cardiac CT angiography in dogs. ANIMALS 4 clinically normal adult Beagles. PROCEDURES In a crossover study, 12 formulations of iohexol solutions differing in iodine dose (300, 400, and 800 mg/kg) and concentration (undiluted and diluted 1:1, 1:2, and 1:3 with saline [0.9% NaCl] solution) were administered IV to each dog. Dynamic CT angiography was performed to evaluate enhancement characteristics of each formulation, with the region of interest set over the aorta. Time-attenuation curves (TACs) were obtained and analyzed. RESULTS Peak arc–type TACs were obtained after administration of all undiluted formulations. Curve shape changed from peak arc type to plateau type as the total volume of the contrast solution (ie, dilution) increased. Prolonged peaks characteristic of plateau-type TACs suggested that a sufficient period of homogeneous attenuation could be achieved for CT scanning with administration of higher iohexol dilutions (1:2 or 1:3) containing higher iodine doses (400 or 800 mg/kg). In particular, attenuation values for plateau-type TACs remained between 200 and 300 Hounsfield units for > 16 seconds after the plateau endpoint was reached for 1:2 and 1:3 dilutions containing an iodine dose of 800 mg/kg. Scan delays of 13 to 17 seconds were computed for those 2 formulations. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that for clinically normal dogs, a scan delay of 13 to 17 seconds could be used to perform cardiac CT angiography with iohexol solutions containing an iodine dose of 800 mg/kg at dilutions of 1:2 or 1:3.
Show more [+] Less [-]Evaluation of glomerular filtration rate by use of dynamic computed tomography and Patlak analysis in clinically normal cats
2011
Chang, Jinhwa | Ahn, Sejoon | Choi, Sooyoung | Lee, Heechun | Chang, Dongwoo | Choi, Hojung | Lee, Youngwon
Objective: To obtain quantitative variables of the abdominal aorta and both kidneys on the basis of time-attenuation curves (TACs) and to measure glomerular filtration rate (GFR) for each kidney and the global GFR in clinically normal cats by use of dynamic computed tomography (CT) and Patlak analysis. Animals: 9 healthy cats. Procedures: All the cats were anesthetized with propofol. Anesthesia was maintained by administration of isoflurane, and CT examination was performed in the anesthetized cats. The TACs and renal volume were measured by use of the baseline precontrast and single-slice dynamic scans. The CT-GFR of each kidney and the global CT-GFRs were calculated via Patlak plot analysis. Results: CT-GFR results from 7 cats were valid. Peak aortic enhancement was detected between 9.0 and 14.0 seconds after iohexol injection, and the initial peak time of renal parenchymal enhancement was 15 to 24 seconds after iohexol injection. Mean ± SD global GFR was 2.06 ± 0.62 mL/min/kg. Mean ± SD CT-GFR of the right and left kidneys was 0.97 ± 0.32 mL/min/kg and 1.05 ± 0.31 mL/min/kg, respectively. Conclusions and Clinical Relevance: The CT-GFR method can be rapidly and conveniently performed in clinically normal cats. This combined structural-functional approach provided physiologic and morphological information on the kidneys of cats.
Show more [+] Less [-]In vitro ultrasonographic appearance of the normal and verminous equine aorta, cranial mesenteric artery, and its branches
1989
Wallace, K.D. | Selcer, B.A. | Tyler, D.E. | Brown, J.
Ninety-one equine aortic and cranial mesenteric arterial segments were evaluated ultrasonographically in a water bath. On the basis of pathologic evidence of verminous arteritis, arterial segments were classified into 4 categories, and the ultrasonographic characteristics of each group were evaluated. Normal arteries (class 1) were ultrasonographically characterized by a smooth luminal surface layer and uniform wall thickness and echogenicity. Arteries with only histopathologic evidence of verminous arteritis (class 2) were ultrasonographically characterized by a smooth luminal surface layer, uniform thickness, uniform echogenicity, and the presence of a hyperechoic luminal layer. Arteries with both gross and histopathologic evidence of verminous arterities (class 3) were characterized ultrasonographically by an irregular luminal surface layer, varying wall thickness, varying wall echogenicity, and the presence of a hyperechoic luminal layer. The ultrasonographic characteristics of arteries with luminal thrombosis (class 4) were an irregular luminal surface, varying wall thickness, and nonuniform echogenicity.
Show more [+] Less [-]Hemodynamic effects of high-frequency oscillatory ventilation in halothane-anesthetized dogs
1989
Bednarski, R.M. | Muir, W.W. III.
Hemodynamic effects of spontaneous ventilation, intermittent positive-pressure ventilation (IPPV), and high-frequency oscillatory ventilation (HFOV) were compared in 6 dogs during halothane anesthesia. Anesthesia was induced with IV thiamylal Na and was maintained with halothane (end-tidal concentration, 1.09%). During placement of catheters, dogs breathed spontaneously through a conventional semiclosed anesthesia circuit. Data were collected, and dogs were mechanically ventilated, using IPPV or HFOV in random order. Ventilation was adjusted to maintain PaCO2 between 38 and 43 mm of Hg during IPPV and HFOV. Cardiac index, aortic blood pressure, and maximum rate of increase of left ventricular pressure were significantly (P less than 0.05) less during HFOV than during spontaneous ventilation, whereas right atrial and pulmonary artery pressure were significantly greater during HFOV than during spontaneous ventilation. During IPPV, only the maximum rate of increase of left ventricular pressure was significantly less than that during spontaneous ventilation.
Show more [+] Less [-]Morphometric evaluation of the portal vein by means of abdominal computed tomographic angiography in dogs free of vascular anomalies
2019
Rossanese, Matteo | Ferreira, Amy | Maddox, Thomas W.
OBJECTIVE To determine the mean diameter of the main portal vein (PV) in healthy dogs by use of CT angiography, identify any associations between PV diameter and certain dog characteristics, and validate a clinically valuable ratio for quantifying the size of the PV. ANIMALS 100 dogs with no hepatic, cardiac, or vascular anomalies that underwent abdominal CT angiography. PROCEDURES Diameters of the main PV, abdominal aorta (Ao), and caudal vena cava (CVC) were measured by 2 observers at a defined location on postcontrast CT angiographic images in axial, sagittal, and transverse planes. Dog characteristics were evaluated for associations with PV diameter, and a PV:Ao diameter ratio was calculated. Intraclass correlations were calculated to assess intra- and interobserver agreement in vessel diameter measurements. RESULTS Mean diameter values were 7.9 mm (range, 4.1 to 14.8 mm) for the PV, 8.9 mm (range, 3.7 to 13.7 mm) for the Ao, and 11.4 mm (range, 4.4 to 22.5 mm) for the CVC. The PV:Ao diameter ratio was 0.91 mm. The PV diameter was significantly associated with dog body weight but not with dog age, sex, or neuter status. Intra- and interobserver reliabilities for measurements of all 3 vessels were considered excellent (intraclass correlation coefficients > 0.85). CONCLUSIONS AND CLINICAL RELEVANCE Findings indicated that the PV:Ao diameter ratio was a repeatable measurement that may be useful for evaluating the size of the portal vasculature in dogs and possibly for distinguishing healthy PVs from abnormal PVs in dogs with hepatic vascular anomalies.
Show more [+] Less [-]Effects of ketamine-xylazine intravenous bolus injection on cardiovascular function in rabbits
2010
Baumgärtner, Christine | Bollerhey, Melanie | Ebner, Johanna | Laacke-Singer, Lien | Schuster, Tibor | Erhardt, Wolf
The direct effects of ketamine-xylazine (KET-XYL) on vascular function have not been investigated in rabbits. The short-term cardiovascular effects of intravenous (IV) KET-XYL bolus injection, therefore, should be investigated using vascular ultrasonography.In this prospective experimental study, KET-XYL anesthesia was induced IV in 9 female New Zealand White rabbits before 3 defined test bolus injections of KET-XYL were given IV. Before and for 10 min after each KET-XYL injection vascular and hemodynamic variables were recorded at the left common carotid artery (ACC) after the 1st injection, and at the abdominal aorta (AA) after the 2nd injection. Echocardiography was performed after the 3rd injection to investigate changes in cardiac parameters.Ketamine-xylazine IV caused a significant increase in vessel diameter at the ACC and AA. Average volumetric flow significantly decreased at the ACC and pulsatility index significantly decreased at the AA. Fractional shortening (FS) and heart rate significantly decreased, while mean arterial blood pressure initially increased.Bolus injections of KET-XYL IV produced a transient vasodilatation at the ACC and AA. Despite central vasodilatation, bradycardia, and decrease of FS and average volumetric flow (VFave), mean arterial blood pressure did not significantly decrease indicating well-preserved cardiovascular compensatory mechanism after the ratio and doses of KET-XYL IV bolus injections used in this study.
Show more [+] Less [-]