Refine search
Results 1-10 of 22
Cardiovascular and pharmacokinetic effects of isoxsuprine in the horse.
1986
Matthews N.S. | Gleed R.D. | Short C.E. | Burrows K.
Dynamic contrast-enhanced computed tomography in 11 dogs with orofacial tumors.
2023
Mortier, Jérémy | Maddox, Thomas W | Blackwood, Laura | La Fontaine, Matthew D | Busoni, Valeria
peer reviewed | [en] OBJECTIVE: Treatment of orofacial tumors in dogs is associated with high morbidity and reliable prognostic factors are lacking. Dynamic contrast-enhanced computed tomography (DCECT) can be used to assess tumor perfusion. The objectives of this study were to describe the perfusion parameters of different types of orofacial tumors and to describe the changes in perfusion parameters during radiotherapy (RT) in a subset of them. ANIMALS: 11 dogs with orofacial tumors prospectively recruited. CLINICAL PRESENTATION AND PROCEDURES: All dogs had baseline DCECT to assess blood volume (BV), blood flow (BF), and transit time (TT). Five dogs had repeat DCECT during megavoltage RT. RESULTS: 5 squamous cell carcinomas, 3 sarcomas, 1 melanoma, 1 histiocytic sarcoma, and 1 acanthomatous ameloblastoma were included. Blood volume and BF were higher in squamous cell carcinomas than in sarcomas, although no statistical analysis was performed. At repeat DCECT, 4 dogs showed a reduction in the size of their tumor during RT. Among these dogs, 3 showed an increase in BV and BF and 1 a decrease in these parameters between the baseline and the follow-up DCECT. The only dog whose tumor increased in size between the first and the second DCECT showed a decrease in BV and BF. CLINICAL RELEVANCE: Perfusion parameters derived from DCECT were described in a series of dogs with various types of orofacial tumors. The results suggest that epithelial tumors could have higher BV and BF than mesenchymal tumors, although larger sample sizes are needed to support these preliminary findings.
Show more [+] Less [-]Dynamic contrast-enhanced computed tomography in 11 dogs with orofacial tumors.
2023
Mortier, Jérémy | Maddox, Thomas W | Blackwood, Laura | La Fontaine, Matthew D | Busoni, Valeria
peer reviewed | [en] OBJECTIVE: Treatment of orofacial tumors in dogs is associated with high morbidity and reliable prognostic factors are lacking. Dynamic contrast-enhanced computed tomography (DCECT) can be used to assess tumor perfusion. The objectives of this study were to describe the perfusion parameters of different types of orofacial tumors and to describe the changes in perfusion parameters during radiotherapy (RT) in a subset of them. ANIMALS: 11 dogs with orofacial tumors prospectively recruited. CLINICAL PRESENTATION AND PROCEDURES: All dogs had baseline DCECT to assess blood volume (BV), blood flow (BF), and transit time (TT). Five dogs had repeat DCECT during megavoltage RT. RESULTS: 5 squamous cell carcinomas, 3 sarcomas, 1 melanoma, 1 histiocytic sarcoma, and 1 acanthomatous ameloblastoma were included. Blood volume and BF were higher in squamous cell carcinomas than in sarcomas, although no statistical analysis was performed. At repeat DCECT, 4 dogs showed a reduction in the size of their tumor during RT. Among these dogs, 3 showed an increase in BV and BF and 1 a decrease in these parameters between the baseline and the follow-up DCECT. The only dog whose tumor increased in size between the first and the second DCECT showed a decrease in BV and BF. CLINICAL RELEVANCE: Perfusion parameters derived from DCECT were described in a series of dogs with various types of orofacial tumors. The results suggest that epithelial tumors could have higher BV and BF than mesenchymal tumors, although larger sample sizes are needed to support these preliminary findings.
Show more [+] Less [-]Computed tomographic evaluation of pancreatic perfusion in healthy dogs
2020
Kloer, Timothy B. | Rao, Sangeeta | Twedt, David C. | Marolf, Angela J.
OBJECTIVE To evaluate the feasibility of contrast-enhanced CT for assessment of pancreatic perfusion in healthy dogs. ANIMALS 6 healthy purpose-bred female Treeing Walker Coonhounds. PROCEDURES Contrast-enhanced CT of the cranial part of the abdomen was performed with 3-mm slice thickness. Postprocessing computer software designed for evaluation of human patients was used to calculate perfusion data for the pancreas and liver by use of 3-mm and reformatted 6-mm slices. Differences in perfusion variables between the pancreas and liver and differences in liver-specific data of interest were evaluated with the Friedman test. RESULTS Multiple pancreatic perfusion variables were determined, including perfusion, peak enhancement index, time to peak enhancement, and blood volume. The same variables as well as arterial, portal, and total perfusion and hepatic perfusion index were determined for the liver. Values for 6-mm slices appeared similar to those for 3-mm slices. The liver had significantly greater median perfusion and peak enhancement index, compared with the pancreas. CONCLUSIONS AND CLINICAL RELEVANCE Measurement of pancreatic perfusion with contrast-enhanced CT was feasible in this group of dogs. Hepatic arterial and pancreatic perfusion values were similar to previously published findings for dogs, but hepatic portal and hepatic total perfusion measurements were not. These discrepancies might have been attributable to physiologic differences between dogs and people and related limitations of the CT software intended for evaluation of human patients. Further research is warranted to assess reliability of perfusion variables and applicability of the method for assessment of canine patients with pancreatic abnormalities.
Show more [+] Less [-]Effect of contrast medium injection rate on computed tomography-derived renal perfusion estimates obtained with the maximum slope method in healthy Beagles
2019
Yi, Sang-gwŏn | Kim, Cheolhyun | Yoon, Sooa | Choi, Jihye
OBJECTIVE To evaluate the effect of contrast medium injection rate on CT-derived renal perfusion estimates obtained with the maximum slope method in healthy small dogs. ANIMALS 6 healthy sexually intact male purpose-bred Beagles. PROCEDURES All dogs underwent CT perfusion analysis 3 times in a crossover design, receiving a different contrast medium injection rate (1.5, 3.0, and 4.5 mL/s) each time, with a 1-week interval between imaging sessions. All CT images were obtained at the level of the left renal hilus. The time to peak aortic enhancement (TPAE) and time to initial renal venous enhancement (TIRVE) were measured from time-attenuation curves. The renal CT perfusion estimates (blood flow and blood volume) were estimated by use of the maximum slope method, which assumes no venous outflow of contrast medium during CT perfusion analysis. RESULTS The TPAE occurred at or before the TIRVE at all injection rates. Median values of estimated blood flow and blood volume did not differ significantly among injection rates. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that the assumption of no venous outflow of contrast medium during renal CT perfusion analysis with the maximum slope method was satisfied for all 3 contrast medium injection rates in the evaluated dogs. A low injection rate may be more practical than higher injection rates that require large catheters for CT perfusion analysis in small dogs such as Beagles.
Show more [+] Less [-]Evaluation of liver lesions by use of shear wave elastography and computed tomography perfusion imaging after radiofrequency ablation in clinically normal dogs
2018
Lee, Dahae | Park, Seungjo | Ang, Mary Jasmin C. | Park, Jun-Gyu | Yoon, Sooa | Kim, Cheolhyun | Yi, Sang-gwŏn | Cho, Kyoung-oh | Choi, Jihye
OBJECTIVE To evaluate acute changes of the liver by use of shear wave elastography (SWE) and CT perfusion after radiofrequency ablation (RFA). ANIMALS 7 healthy Beagles. PROCEDURES RFA was performed on the liver (day 0). Stiffness of the ablation lesion, transitional zone, and normal parenchyma were evaluated by use of SWE, and blood flow, blood volume, and arterial liver perfusion of those regions were evaluated by use of CT perfusion on days 0 and 4. All RFA lesions were histologically examined on day 4. RESULTS Examination of the SWE color-coded map distinctly revealed stiffness of the liver tissue, which increased from the normal parenchyma to the transitional zone and then to the ablation zone. For CT perfusion, blood flow, blood volume, and arterial liver perfusion decreased from the transitional zone to the normal parenchyma and then to the ablation zone. Tissue stiffness and CT perfusion variables did not differ significantly between days 0 and 4. Histologic examination revealed central diffuse necrosis and peripheral hyperemia with infiltration of lymphoid cells and macrophages. CONCLUSIONS AND CLINICAL RELEVANCE Coagulation necrosis induced a loss of blood perfusion and caused tissue hardening (stiffness) in the ablation zone. Hyperemic and inflammatory changes of the transitional zone resulted in increased blood perfusion. Acute changes in stiffness and perfusion of liver tissue after RFA could be determined by use of SWE and CT perfusion. These results can be used to predict the clinical efficacy of RFA and to support further studies, including those involving hepatic neoplasia.
Show more [+] Less [-]Cutaneous laser-Doppler velocimetry in nine animal species
1991
The assessment of cutaneous microcirculation by laser-Doppler velocimetry (LDV) has been primarily limited to human studies. The purpose of this investigation was to establish normal values in various species and anatomic sites for blood flow, velocity, and volume as determined by LDV. Microcirculation was measured with a laser-Doppler velocimeter in 54 animals, 6 healthy animals from each of 9 species. The standard sites used were the buttocks, convex surface of the ear, metacarpal pad, humeroscapular junction, thoracolumbar junction, ventral portion of the abdomen, dorsal metacarpus (hooved animals), and ventral surface of the tail (horse). Significant differences in blood flow, velocity, and volume were measured between species and sites within species. The ventral portion of the abdomen consistently had the highest relative blood flow across all species except the monkey. Measurements in the canine metacarpal pad had a high SD, possibly indicating the stratum corneum and epidermis to be too thick for LDV. Our findings provide baseline data in several species, with application of LDV in comparative dermatologic research.
Show more [+] Less [-]Effect of meal feeding on plasma volume and urinary electrolyte clearance in ponies
1990
Clarke, L.L. | Argenzio, R.A. | Roberts, M.C.
The effect of meal size and frequency on plasma volume, plasma aldosterone concentration and urinary Na and K clearances was determined in ponies. A daily maintenance ration of hay-grain pellets was provided either as a multiple feeding regimen, ie, 12 equal portions fed at 2-hour intervals, or as single large feedings, ie, half the ration fed every 12 hours at 0800 and 2000 hours. Only the effect of the single morning feeding was studied, using the latter regimen. Serial measurements of plasma volume were made by use of an indicator-dilution technique and indocyanine green (0.15 mg/kg of body weight, IV) that allowed repeated determinations at 2-hour intervals. Ingestion of the single large meal caused a 15% decrease in plasma volume by the end of a 1-hour feeding period. Feeding hypovolemia was confirmed by a coincident increase in plasma protein concentration (12%) and, in separate experiments, by analysis of postfeeding changes in the elimination of Evans blue dye. Plasma aldosterone concentration was significantly (P < 0.05) increased from 2 to 5 hours after feeding. Urinary Na clearance decreased in response to feeding and remained lower than the prefeeding value until 9 hours after feeding. Urinary K clearance increased from prefeeding and reached a peak value between 5 and 7 hours after feeding. Creatinine clearance was unaffected. In contrast, the aforementioned variables were unchanged during the multiple regimen. Results indicate that ingestion of a large concentrate meal by ponies causes periprandial hypovolemia, activation of the renin-angiotensin-aldosterone system, and a subsequent antinaturesis-kaluresis that lasts for several hours.
Show more [+] Less [-]Effect of slice thickness on computed tomographic perfusion analysis of the pancreas in healthy dogs
2020
Park, Seungjo | Jung, Jin-Woo | Je, Hyejin | Jang, Youjung | Choi, Jihye
OBJECTIVE To evaluate the effect of slice thickness on CT perfusion analysis of the pancreas in healthy dogs. ANIMALS 12 healthy Beagles. PROCEDURES After precontrast CT scans, CT perfusion scans of the pancreatic body were performed every second for 30 seconds by sequential CT scanning after injection of contrast medium (iohexol; 300 mg of 1/kg) at a rate of 3 mL/s. Each dog underwent CT perfusion scans twice in a crossover-design study with 2 different slice thicknesses (2.4 and 4.8 mm). Computed tomographic pancreatic perfusion variables, including blood flow, blood volume determined with the maximum slope model, times to the start of enhancement and peak enhancement, permeability, and blood volume determined by Patlak plot analysis, were measured independently by 2 reviewers. The CT perfusion variables were compared between slice thicknesses. Interoperator reproducibility was determined by ICC calculation. RESULTS Interoperator reproducibility of CT perfusion variable measurements was excellent on 2.4-mm (mean ± SD ICC, 0.81 ± 0.17) and 4.8-mm (0.90 ± 0.07) slice thicknesses, except for time to peak pancreatic enhancement on 2.4-mm-thick slices, which had moderate reproducibility (intraclass correlation coefficient, 0.473). There was no significant difference in measurements of blood flow, blood volume by either method, times to the start and peak of pancreatic enhancement, or permeability between slice thicknesses. CONCLUSIONS AND CLINICAL RELEVANCE Results supported that a thin slice thickness of 2.4 mm can be used for assessment of pancreatic perfusion variables in healthy dogs.
Show more [+] Less [-]Use of a modified passive leg-raising maneuver to predict fluid responsiveness during experimental induction and correction of hypovolemia in healthy isoflurane-anesthetized pigs
2019
Paranjapae, Vaidehi V. | Shih, Andre C. | Garcia-Pereira, Fernando L.
OBJECTIVE To evaluate the use of a modified passive leg-raising maneuver (PLRM) to predict fluid responsiveness during experimental induction and correction of hypovolemia in isoflurane-anesthetized pigs. ANIMALS 6 healthy male Landrace pigs. PROCEDURES Pigs were anesthetized with isoflurane, positioned in dorsal recumbency, and instrumented. Following induction of a neuromuscular blockade, pigs were mechanically ventilated throughout 5 sequential experimental stages during which the blood volume was manipulated so that subjects transitioned from normovolemia (baseline) to hypovolemia (blood volume depletion, 20% and 40%), back to normovolemia, and then to hypervolemia. During each stage, hemodynamic variables were measured before and 3 minutes after a PLRM and 1 minute after the pelvic limbs were returned to their original position. The PLRM consisted of raising the pelvic limbs and caudal portion of the abdomen to a 15° angle relative to the horizontal plane. RESULTS Hemodynamic variables did not vary in response to the PLRM when pigs were normovolemic or hypervolemic. When pigs were hypovolemic, the PLRM resulted in a significant increase in cardiac output and decrease in plethysomographic variability index and pulse pressure variation. When the pelvic limbs were returned to their original position, cardiac output and pulse pressure variation rapidly returned to their pre-PLRM values, but the plethysomographic variability index did not. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested a modified PLRM might be useful for identification of hemodynamically unstable animals that are likely to respond to fluid therapy. Further research is necessary to validate the described PLRM for prediction of fluid responsiveness in clinically ill animals.
Show more [+] Less [-]