Intraocular pressure in clinically normal dromedary camels (Camelus dromedarius)
2015
Marzok, Mohamed A. | El-khodery, Sabry A.
OBJECTIVE To determine the intraocular pressure (IOP) in healthy dromedary camels (Camelus dromedarius). ANIMALS 24 clinically normal dromedary camels. PROCEDURES For each camel, the IOP of both eyes was measured with applanation tonometry. Three measurements with < 5% variance were obtained for each eye on the same day of the week for 3 consecutive weeks. Mean IOP was calculated for each eye on each day for comparison purposes. RESULTS Mean ± SD IOPs for the right (31.1 ± 2.1 mm Hg) and left (30.8 ± 1.9 mm Hg) eyes of immature camels were significantly higher than those for the right (27.1 ± 1.2 mm Hg) and left (28.2 ± 1.2 mm Hg) eyes of mature camels. Intra-assay and interassay coefficients of variation (CVs) for IOP measurements of the right and left eyes did not differ significantly between immature and mature camels. Interassay CVs of IOP measurements for the right and left eyes ranged from 1.5% to 12.1% and 1.2% to 10.3%, respectively, for immature camels and from 1.2% to 17.2% and 1.7% to 18.8%, respectively, for mature camels. Intra-assay CVs of IOP measurements for the right and left eyes ranged from 1.5% to 10.6% and 1.9% to 9.6%, respectively, for immature camels and from 2.8% to 16.9% and 2.7% to 12.4%, respectively, for mature camels. Age was negatively correlated (r = −0.403) with IOP. CONCLUSIONS AND CLINICAL RELEVANCE Results provided a reference and might aid in the diagnosis of glaucoma and uveitis during complete ophthalmic examinations of dromedary camels.
Show more [+] Less [-]Reliability of manual measurements of corneal thickness obtained from healthy canine eyes using spectral-domain optical coherence tomography (SD-OCT)
2014
Alario, Anthony F. | Pirie, Christopher G.
The purpose of this study was to manually measure corneal thickness in canine eyes using a spectral-domain optical coherence tomography (SD-OCT) device and to assess intra- and inter-observer reliability of this technique. Twenty healthy dogs with a mean age of 4.7 y were examined. A 6-mm corneal pachymetry protocol was carried out by 1 operator using 1 SD-OCT device in both eyes of each animal. Measurements were obtained manually and in duplicate by 2 independent investigators (> 24 h apart), using the built-in caliper function. Measurements included epithelial thickness (ET), non-epithelial thickness (NET), and central corneal thickness (CCT). The overall mean ET, NET, and CCT for all eyes examined were 72.3 ± 4.6 μm, 538.9 ± 42.5 μm, and 611.2 ± 40.3 μm, respectively. There was no significant difference in ET, NET, or CCT based on the eye examined [oculus dexter (OD) versus oculus sinister (OS)], age, or gender of the animal. There was no significant difference in replicate measurements of ET, NET, or CCT done by the same operator, although a small but significant difference was noted between operators for ET measurements only. The mean difference in ET between operators was 0.6 μm (P = 0.03). The coefficient of variation ranged from 0.5% to 9.27% and intraclass correlation coefficient ranged from 0.35 to 0.97. Based on these results, manual measurements of corneal thickness in canine eyes using a portable SD-OCT device provided ET, NET, and CCT measurements with clinically acceptable intra- and inter-observer reliability.
Show more [+] Less [-]Evaluation of a novel accelerometer for kinetic gait analysis in dogs
2014
Clark, Kyle | Caraguel, Charles | Leahey, Lorne | Beraud, Romain
The objective of this study was to evaluate a novel accelerometer-based sensor system, the Walkabout Portable Gait Monitor (WPGM), for use in kinetic gait analysis of dogs. The accelerometer was compared to the common reference standard of force platform analysis. Fifteen client-owned, orthopedically sound dogs of various breeds underwent simultaneous force platform and accelerometer gait trials to measure peak vertical forces (PVFs). The agreement between PVF for the accelerometer and force platform was measured using concordance correlation coefficient (CCC) and was found, overall, to be moderate [CCC = 0.51; 95% confidence interval (CI): 0.46 to 0.56]. The agreement between PVF for the accelerometer and force platform for the forelimbs was positive and substantial (CCC = 0.79; 95% CI: 0.74 to 0.84) and for the hind limbs was positive and low (CCC = 0.34; 95% CI: 0.29 to 0.38). As measured by the accelerometer, PVF was systematically higher than as measured by the force platform (forelimbs 55.3 N, hind limbs 144.3 N). It was also found that, when positioned over the lumbar spine, the WPGM cannot measure PVF of the individual forelimbs and hind limbs, which limits its use as a clinical tool to measure kinetic variables in dogs.
Show more [+] Less [-]Effects of isoflurane with and without dexmedetomidine or remifentanil on heart rate variability before and after nociceptive stimulation at different multiples of minimum alveolar concentration in dogs
2013
Voigt, Anne M. | Bergfeld, Carina | Beyerbach, Martin | Kastner, Sabine B.R.
Objective: To evaluate the influence of 3 anesthetic protocols and multiples of minimum alveolar concentration (MAC) on heart rate variability (HRV) with and without nociceptive stimulation in dogs. Animals: 6 healthy adult Beagles. Procedures: Each dog was anesthetized 3 times: with isoflurane alone, with isoflurane and a constant rate infusion of dexmedetomidine (IsoD; 3 μg/kg/h, IV), and with isoflurane and a constant rate infusion of remifentanil (IsoR; 18 μg/kg/h, IV). Individual MAC was determined via supramaximal electrical stimulation. Sinus rhythm–derived intervals between 2 adjacent R-R intervals were exported from ECG recordings. Selected HRV time and frequency domain variables were obtained (at 2-minute intervals) and analyzed offline with signed rank tests before and after stimulation at 0.75, 1.0, and 1. 5 MAC for each anesthetic session. Results: The isoflurane session had the overall lowest prestimulation SDNN (SD of all R-R intervals) values. Prestimulation SDNN values decreased significantly with increasing MAC in all sessions. For the IsoD session, SDNN (milliseconds) or high-frequency power (milliseconds2) was inversely correlated with MAC (Spearman rank correlation coefficient for both variables, −0.77). In the isoflurane and IsoR sessions, heart rate increased significantly after stimulation. In the IsoD session, poststimulation SDNN was increased significantly, compared with prestimulation values, at 0.75 and 1.0 MAC. Conclusions and Clinical Relevance: On the basis of SDNN and high-frequency power values, anesthetic levels between 0.75 and 1.5 MAC within the same anesthetic protocol could be differentiated, but with a large overlap among protocols. Usefulness of standard HRV variables for assessment of anesthetic depth and nociception in dogs is questionable.
Show more [+] Less [-]Description of technique and lower reference limit for magnetic resonance imaging of hippocampal volumetry in dogs
2013
Milne, Marjorie E. | Anderson, Garry A. | Chow, Kathleen E. | O'Brien, Terrence J. | Moffat, Bradford A. | Long, Sam N.
Objective: To evaluate the use of high-resolution MRI for hippocampal volumetry in dogs and to define a lower reference limit for hippocampal formation (HF) volume. Animals: 20 dogs (with no history of seizures and no underlying structural brain disease) that underwent MRI of the brain. Procedures: The MRI protocol included a high-resolution T1-weighted 3-D ultrafast gradient-echo sequence aligned in a dorsal plane perpendicular to the long axis of the HF. Images obtained with MRI were retrospectively analyzed by 2 observers (A and B). Intraobserver and interobserver agreement were calculated with the Lin concordance correlation coefficient. Volume measurements of the HF were adjusted for intracranial volume, and a lower 95% reference limit for adjusted HF volume was calculated. Results: There was substantial intraobserver agreement (Lin concordance correlation coefficient, 0.97 [95% confidence interval {CI}, 0.94 to 0.99]) but poor interobserver agreement (Lin concordance correlation coefficient, 0.63 [95% CI, 0.37 to 0.79]). The lower 95% reference limit for adjusted HF volume was 0.56 cm3 (90% CI, 0.52 to 0.60 cm3) for the right HF and 0.55 cm3 (90% CI, 0.52 to 0.58 cm3) for the left HF. Conclusions and Clinical Relevance: HF volumes should be adjusted for intracranial volume to account for the large variation in canine skull size. The amount of time required to perform HF volumetry and low interobserver agreement may restrict this technique to research applications, such as the investigation of epileptic patients for hippocampal sclerosis or other cognitive disorders.
Show more [+] Less [-]Evaluation of long-term glucose homeostasis in lean and obese cats by use of continuous glucose monitoring
2012
Hoenig, Margarethe | Pach, Nicole | Thomaseth, Karl | DeVries, Frerich | Ferguson, Duncan C.
Objective: To evaluate intraday and interday variations in glucose concentrations in cats and to test the utility of a continuous glucose monitoring system (CGMS). Animals: 6 lean and 8 long-term (> 5 years) obese cats. Procedures: Blood glucose concentrations were measured during the course of 156 hours by use of a laboratory hexokinase-based reference method and a handheld glucometer. Interstitial glucose concentrations were evaluated with a CGMS. Results: Paired measures of glucose concentrations obtained with the CGMS typically were marginally higher than concentrations for the reference method and less biased than concentrations obtained with the glucometer. This was partially confirmed by the concordance correlation coefficients of the concentration for the CGMS or glucometer versus the concentration for the reference method, although the correlation coefficients were not significantly different. Mean ± SD area under the curve for the glucose concentration (AUCG) did not differ significantly between lean (14.0 ± 0.5 g/dL•h) and obese (15.2 + 0.5 g/dL•h) cats during the 156-hour period, but one of the obese cats had a much higher AUCG. Within-day glucose variability was small in both lean and obese cats. Conclusions and Clinical Relevance: Glucose homeostasis was maintained, even in long-term obese cats, and intraday glucose fluctuations were small. One obese cat might have been classified as prediabetic on the basis of the AUCG, which was approximately 25% higher than that of the other obese and lean cats. The CGMS can be useful in the evaluation of long-term effects of drugs or diet on glucose homeostasis in cats.
Show more [+] Less [-]Evaluation of the association between runt-related transcription factor 2 expression and intervertebral disk aging in dogs
2012
Itoh, Hisanori | Hara, Yasushi | Tagawa, Masahiro | Kato, Tsuyoshi | Ochi, Hiroki | Koga, Daisuke | Ōkawa, Atsushi | Asou, Yoshinori
Objective: To investigate the relationship between runt-related transcription factor 2 (RUNX2) expression in canine nucleus pulposus (NP) cells and intervertebral disk aging in chondrodystrophoid dogs. Animals: 7 healthy Beagles (mean age, 35.6 months) and 11 Dachshunds with herniated disks (mean age, 61 months). Procedures: All dogs underwent MRI examination of the thoracic and lumbar vertebral column immediately before sample collection under general anesthesia. The disk center–to–CSF T2-weighted signal intensity ratio was determined for healthy Beagles. Samples of NP were obtained from nonherniated disks in healthy Beagles and from herniated disks during surgical treatment of hospitalized Dachshunds. Samples were evaluated for RUNX2 and matrix metalloproteinase 13 transcript expression via reverse transcriptase PCR assay; RUNX2 protein expression was evaluated via immunohistochemical analysis, and correlation between these variables and age of dogs was evaluated. A 3′ and 5′ rapid amplification of cDNA ends method was used to identify the RUNX2 coding region. Results: RUNX2 cDNA had > 97% conservation with the human cDNA sequence and approximately 95% conservation with the mouse cDNA sequence; RUNX2 and matrix metalloproteinase 13 mRNA expression and RUNX2 protein expression in NP cells were positively correlated with age. The disk center–to–CSF T2-weighted signal intensity ratio was negatively correlated with RUNX2 protein expression in the NP of healthy dogs. Conclusions and Clinical Relevance: Results indicated that RUNX2 mRNA and protein expression in the NP are enhanced in aging intervertebral disks in dogs.
Show more [+] Less [-]Evaluation of high–molecular weight adiponectin in horses
2012
Wooldridge, Anne A. | Edwards, Heather Gray | Plaisance, Eric P. | Applegate, Rory | Taylor, Debra R. | Taintor, Jennifer | Zhong, Qiao | Judd, Robert L.
Objective: To characterize adiponectin protein complexes in lean and obese horses. Animals: 26 lean horses and 18 obese horses. Procedures: Body condition score (BCS) and serum insulin activity were measured for each horse. Denaturing and native western blot analyses were used to evaluate adiponectin complexes in serum. A human ELISA kit was validated and used to quantify high–molecular weight (HMW) complexes. Correlations between variables were made, and HMW values were compared between groups. Results: Adiponectin was present as a multimer consisting of HMW (> 720-kDa), low-molecular weight (180-kDa), and trimeric (90-kDa) complexes in serum. All complexes were qualitatively reduced in obese horses versus lean horses, but the percentage of complexes < 250 kDa was higher in obese versus lean horses. High–molecular weight adiponectin concentration measured via ELISA was negatively correlated with serum insulin activity and BCS and was lower in obese horses (mean ± SD, 3.6 ± 3.9 μg/mL), compared with lean horses (8.0 ± 4.6 μg/mL). Conclusions and Clinical Relevance: HMW adiponectin is measurable via ELISA, and concentration is negatively correlated with BCS and serum insulin activity in horses. A greater understanding of the role of adiponectin in equine metabolism will provide insight into the pathophysiology of metabolic disease conditions.
Show more [+] Less [-]Effects of continuous or intermittent lipopolysaccharide administration for 48 hours on the systemic inflammatory response in horses
2012
Tadros, Elizabeth M. | Frank, Nicholas
Objective: To determine whether the method of lipopolysaccharide (LPS) administration (intermittent vs continuous) affects the magnitude and duration of the systemic inflammatory response in horses and whether prolonged (48 hours) endotoxemia induces laminitis. Animals: 12 healthy adult horses (10 mares and 2 geldings). Procedures: Horses were randomly assigned to receive LPS (total dose, 80 μg; n = 4) or saline (0.9% NaCl) solution (80 mL/h; 4) via constant rate infusion or 8 bolus IV injections of LPS (10 μg, q 6 h;4) during a 48-hour period. Physical examinations were performed every 4 hours, inflammatory cytokine gene expression was determined for blood samples obtained every 8 hours, and IV glucose tolerance tests were performed. Results: All LPS-treated horses had signs of depression and mild colic; those signs abated as the study progressed. Administration of LPS increased expression of interleukin-1β, interleukin-6, and interleukin-8, but results were not significantly different between LPS treatment groups. Cytokine expression was significantly higher on the first day versus the second day of LPS treatment. Interleukin-1β expression was positively correlated with rectal temperature and expression of other cytokines. Glucose and insulin dynamics for both LPS groups combined did not differ significantly from those of the saline solution group. Signs of laminitis were not detected in any of the horses. Conclusions and Clinical Relevance: Horses developed LPS tolerance within approximately 24 hours after administration was started, and the method of LPS administration did not affect the magnitude or duration of systemic inflammation. Laminitis was not induced in horses.
Show more [+] Less [-]Serum insulin-like growth factor-1 measurements in dogs: Performance characteristics of an automated assay and study of some sources of variation
2011
Tvarijonaviciute, Asta | Tecles, Fernando | Carillo, José M. | Rubio, Mónica | Ceron, José J.
The aim of this study was to evaluate the performance characteristics of an automated immunoassay for canine insulin-like growth factor 1 (IGF-1) measurement and to investigate the possible effects of some sources of variation, such as diurnal variations, feeding/fasting cycles, and glucocorticoid administration, in dogs. The immunoassay evaluated had an adequate analytical performance with intra- and inter-assay coefficients of variation (CVs) lower than 10%, linear regression equations with correlation coefficients of 0.9993 and 0.9988 after serial dilutions, and a limit of quantification of 7.1 ng/mL that was even lower than that reported by the manufacturer. The assay was significantly affected by hemolysis and lipemia producing a significant decrease in IGF-1 concentrations, but not by bilirubinemia. Serum IGF-1 concentrations did not show significant diurnal changes in fed or fasted dogs and were not affected by glucocorticoid administration.