Refine search
Results 1-4 of 4
Comparison of insertion characteristics of tapered and cylindrical transfixation pins in third metacarpal bones of equine cadavers
2017
Adams, Mackenzie K. | Lescun, Timothy B. | Mechem, Alexis S. | Johnson, Whitney R. | Griffin, T Hall | Main, Russell P.
OBJECTIVE To compare heat generation and mechanical bone damage for tapered and cylindrical transfixation pins during drilling, tapping, and pin insertion in equine third metacarpal bones. SAMPLE 16 pairs of cadaveric equine third metacarpal bones. PROCEDURES For cylindrical pin insertion, a 6.2-mm hole was drilled and tapped with a cylindrical tap, and then a standard 6.3-mm pin was inserted. For tapered pin insertion, a 6.0-mm hole was drilled, reamed with a tapered reamer, and tapped with a tapered tap, and then a 6.3-mm tapered pin was inserted. Paired t tests and 1-way ANOVAs were used to compare heat generation (measured by use of thermocouples and thermography), macrodamage (assessed by use of stereomicroscopy), and microdamage (assessed by examination of basic fuchsin–stained histologic specimens) between cylindrical and tapered pins and between tapered pins inserted to various insertion torques. RESULTS Tapered pin insertion generated less heat but resulted in more bone damage than did cylindrical pin insertion when pins were inserted to the same insertion torque. Insertion of tapered pins to increasing insertion torques up to 16 N•m resulted in increased heat generation and bone damage. CONCLUSIONS AND CLINICAL RELEVANCE Tapered pin insertion resulted in lower heat production than did cylindrical pin insertion. However, tapered pin insertion resulted in greater bone damage, which likely was attributable to differences in the tapered and cylindrical taps. A tapered pin may be preferable to a cylindrical pin for insertion in equine cortical bone provided that improvements in tap design can reduce bone damage during insertion.
Show more [+] Less [-]In vitro biomechanical evaluation of four surgical techniques for fusion of equine centrodistal and tarsometatarsal joints
2016
Biedrzycki, Adam H. | Grant, Barrie G. | Nemke, Brett | Morello, Samantha L. | Markel, Mark D.
OBJECTIVE To evaluate the biomechanical properties of 4 methods for fusion of the centrodistal and tarsometatarsal joints in horses and compare them among each other and with control tarsi. SAMPLE 24 sets of paired tarsi without substantial signs of osteoarthritis harvested from equine cadavers. PROCEDURES Test constructs (n = 6/type) were prepared from 1 tarsus from each pair to represent surgical drilling; 2 medially to laterally placed kerf-cut cylinders (MLKCs); a single large, dorsally applied kerf-cut cylinder (DKC); and a dorsomedially applied locking compression plate (DMLCP). Constructs and their contralateral control tarsi were evaluated in 4-point bending in the dorsoplantar, lateromedial, and mediolateral directions; internal and external rotation; and axial compression. Bending, torsional, and axial stiffness values were calculated. RESULTS Mean stiffness values were consistently lower for surgical drilling constructs than for contralateral control tarsi. Over all biomechanical testing, surgical drilling significantly reduced joint stability. The MLKC constructs had superior biomechanical properties to those of control tarsi for 4-point bending but inferior properties for external and internal rotation. The DMLCP and DKC constructs were superior to control tarsi in dorsoplantar, rotational, and axial compression directions only; DMLCP constructs had no superior stiffness in lateromedial or mediolateral directions. Only the DKC constructs had greater stiffness in the mediolateral direction than did control tarsi. Over all biomechanical testing, DMLCP and DKC constructs were superior to the other constructs. CONCLUSIONS AND CLINICAL RELEVANCE These biomechanical results suggested that a surgical drilling approach to joint fusion may reduce tarsal stability in horses without clinical osteoarthritis, compared with stability with no intervention, whereas the DMLCP and DKC approaches may significantly enhance stability.
Show more [+] Less [-]Effect of sequential hole enlargement on cortical bone temperature during drilling of 6.2-mm-diameter transcortical holes in the third metacarpal bones of horse cadavers
2011
Lescun, Timothy B. | Frank, Elizabeth A. | Zacharias, Joshua R. | Daggy, Joanne K. | Moore, George E.
Objective—To compare the bone temperature and final hole dimensions associated with sequential overdrilling (SO) and single 6.2-mm drill bit (S6.2DB) methods used to create transcortical holes in the third metacarpal bones (MCIIIs) of horse cadavers. Sample—60 MCIIIs from 30 horse cadavers. Procedures—In phase 1, hole diameter, tap insertion torque, peak bone temperature, and postdrilling bit temperature for 6.2-mm-diameter holes drilled in the lateral or medial cortical region of 12 MCIIIs via each of three 2-bit SO methods with a single pilot hole (diameter, 3.2, 4.5, or 5.5 mm) and the S6.2DB method were compared. In phase 2, 6.2-mm-diameter transcortical holes were drilled via a 2-bit SO method (selected from phase 1), a 4-bit SO method, or a S6.2DB method at 1 of 3 locations in 48 MCIIIs; peak bone temperature during drilling, drill bit temperature immediately following drilling, and total drilling time were recorded for comparison. Results—Hole diameter or tap insertion torque did not differ among phase 1 groups. Mean ± SD maximum bone temperature increases at the cis and trans cortices were significantly less for the 4-bit SO method (3.64 ± 2.01°C and 8.58 ± 3.82°C, respectively), compared with the S6.2DB method (12.00 ± 7.07°C and 13.19 ± 7.41°C, respectively). Mean drilling time was significantly longer (142.9 ± 37.8 seconds) for the 4-bit SO method, compared with the S6.2DB method (49.7 ± 24.3 seconds). Conclusions and Clinical Relevance—Compared with a S6.2DB method, use of a 4-bit SO method to drill transcortical holes in cadaveric equine MCIIIs resulted in smaller bone temperature increases without affecting hole accuracy.
Show more [+] Less [-]Effect of subchondral drilling on repair of partial-thickness cartilage defects of third carpal bones in horses
1989
Shamis, L.D. | Bramlage, L.R. | Gabel, A.A. | Weisbrode, S.
Arthrotomies of middle carpal joints were done on 13 horses, and a 1-cm partial thickness, round defect was made on the radial facet of both third carpal bones. In one joint, 1-mm diameter 1-cm deep holes were drilled within the defect, and one joint was used as a control. Horses were assigned to 2 groups--group 1 (n = 6 horses), 5 drill holes; group 2 (n = 7 horses), 11 drill holes. At 1 and 3 weeks after surgery, differences between joints in synovial fluid total protein values, WBC counts, or results of mucin precipitate tests were not significant (P = 0.005). Physically and radiographically, horses were the same during the 12 initial weeks they were housed in stalls and the 9 weeks they were kept in paddocks. Twenty-one weeks after surgery, horses were euthanatized. Joints with drill holes had a significantly greater area (P less than 0.05) of healthy fibrocartilage new tissue: group 1--33 to 68% new tissue, compared with 0 to 23% new tissue in controls; and group 2--22 to 64% new tissue, compared with 0 to 37% new tissue in controls. Differences between healing of defects with drill holes in groups 1 and 2 were not significant. Thickness of new tissue over drill holes was 33 to 61% of thickness of cartilage adjacent to the defect, and thickness of tissue between drill holes was 11 to 43% (group 1) and 8 to 79% (group 2) of the thickness of cartilage adjacent to the defect. In all defects with drill holes, new tissue in the form of fibrocartilage was detected deep in drill holes, whereas fibrous tissue was observed superficially and adjacent to drill holes.
Show more [+] Less [-]