Refine search
Results 1-10 of 13
Effects of catheter shape, interelectrode spacing, and electrode size on transesophageal atrial pacing in dogs
2016
Sanders, Robert A. | Chapel, Emily H.
OBJECTIVE To determine effects of catheter shape, interelectrode spacing (IS), and electrode size (ES) on pacing threshold (PT), extraneous muscular stimulation (EMS), and zone of capture (ZOC) for dogs undergoing transesophageal atrial pacing (TAP). ANIMALS 10 purpose-bred dogs without cardiac conduction disturbances. PROCEDURES 7 configurations for TAP catheters were tested in each dog to evaluate effects of catheter shape (curved or straight), IS (5, 15, and 25 mm), and ES (2, 4, and 6 mm). Each catheter was passed into the esophagus to a location aboral to the heart and slowly withdrawn until atrial pacing was achieved. Then, catheters were withdrawn in 5-mm increments until pacing could not be achieved. Outcomes measured at each pacing site included PT, degree of EMS, and ZOC. RESULTS There was a significantly lower PT, wider ZOC, and less EMS for the curved catheter than for the straight catheter. An ES of 6 mm induced significantly more EMS than was induced by an ES of 2 or 4 mm. An IS of 5 mm induced significantly less EMS and a significantly narrower ZOC but required a significantly higher PT, compared with results for an ES of 15 or 25 mm. Additionally, there was a significant direct correlation between IS and ZOC. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that a curved catheter with multiple 4-mm electrodes that provides for variable IS would be ideal for TAP in dogs. IMPACT FOR HUMAN MEDICINE TAP catheters currently used in human medicine are straight. The PT in humans may potentially be reduced with curved catheters.
Show more [+] Less [-]Feasibility of flexible endoscopic evaluation of swallowing in healthy dogs
2016
Marks, Stanley L. | Douthitt, Katie L. | Belafsky, Peter C.
OBJECTIVE To assess feasibility of flexible endoscopic evaluation of swallowing (FEES) in awake dogs, determine whether specific variables associated with the oropharyngeal phase of swallowing can be recognized, and evaluate the safety and tolerability of FEES. ANIMALS 6 healthy client-owned large- and giant-breed adult dogs. PROCEDURES A topical anesthetic was applied to the nasal passage of each dog, and a fiberoptic endoscope was passed transnasally until the tip of the scope was positioned in the oropharynx. All dogs voluntarily drank colored water followed by consumption of a commercial canned diet and then a kibble diet mixed with food color. During each swallow, laryngeal and pharyngeal anatomic structures were evaluated and depth of bolus flow prior to the pharyngeal phase of swallowing was assessed. Evidence of bolus retention in the vallecula or pyriform sinuses and laryngeal penetration of the bolus were recorded. RESULTS FEES was completed without major adverse events and was tolerated well by all 6 dogs. Mild, self-limiting epistaxis was noted for 2 dogs. The nasopharynx, oropharynx, and hypopharynx were observed in all dogs; movement of food boluses through the esophagus was observed in 2 dogs, and food boluses in the stomach were visible in 1 dog. Pharyngeal and laryngeal function was considered physiologically normal in all dogs. CONCLUSIONS AND CLINICAL RELEVANCE FEES appeared to be a feasible diagnostic tool for use in large- and giant-breed dogs. Studies are warranted in dogs with oropharyngeal dysphagia to determine whether FEES can be tolerated and whether it can augment videofluoroscopy findings.
Show more [+] Less [-]Description of thoracoscopy and associated short-term cardiovascular and pulmonary effects in healthy cattle
2014
Michaux, Hélène | Nichols, Sylvain | Babkine, Marie | Francoz, David
Objective- To describe the optimal thoracoscopic approach to the bovine pleural cavity and evaluate the short-term effects of thoracoscopy on cardiovascular and pulmonary function of healthy cattle. Sample- 6 healthy adult Holstein cows (12 hemithoraxes). Procedures- For each cow, thoracoscopy was performed in both the left and right hemithoraxes with a 24-hour interval between procedures. Cows were sedated and restrained in a standing position for each thoracoscopic examination. Examination of each hemithorax lasted for 30 minutes. Arterial blood gas variables, heart rate, and respiratory rate were assessed at predetermined times before, during, and after the procedures to monitor cardiovascular and pulmonary function. Thoracic ultrasonography was performed immediately and at 24 hours and 1 week after each thorascopic examination to evaluate the extent of residual pneumothorax. Results- Insertion of the laparoscope into the pleural cavity at the ninth intercostal space 15 cm ventral to the transverse processes of the thoracic vertebrae provided optimal visibility of structures in both the left and right hemithoraxes. Most structures of the pleural cavity were equally visible from both sides except the esophagus and the dorsal branch of the vagus nerve, which were best observed in the left hemithorax, and the pericardium, which was best observed in the right hemithorax. Mild increases in heart and respiratory rates and moderate decreases in arterial oxygen saturation and Pao2 were detected during the procedures. Conclusions and Clinical Relevance-Standing thoracoscopy was well tolerated in healthy adult dairy cattle and needs to be evaluated in cattle with pulmonary disease.
Show more [+] Less [-]Effects of treatment with oxytocin, xylazine butorphanol, guaifenesin, acepromazine, and detomidine on esophageal manometric pressure in conscious horses
2002
Wooldridge, Anne A. | Eades, Susan C. | Hosgood, Giselle L. | Moore, Rustin M.
Objective-To compare effects of oxytocin, acepromazine maleate, xylazine hydrochloride-butorphanol tartrate, guaifenesin, and detomidine hydrochloride on esophageal manometric pressure in horses. Animals-8 healthy adult horses. Procedure-A nasogastric tube, modified with 3 polyethylene tubes that exited at the postpharyngeal area, thoracic inlet, and distal portion of the esophagus, was fitted for each horse. Amplitude, duration, and rate of propagation of pressure waveforms induced by swallows were measured at 5, 10, 20, 30, and 40 minutes after administration of oxytocin, detomidine, acepromazine, xylazine-butorphanol, guaifenesin, or saline (0.9% NaCl) solution. Number of spontaneous swallows, spontaneous events (contractions that occurred in the absence of a swallow stimulus), and high-pressure events (sustained increases in baseline pressure of > 10 mm Hg) were compared before and after drug administration. Results-At 5 minutes after administration, detomidine increased waveform amplitude and decreased waveform duration at the thoracic inlet. At 10 minutes after administration, detomidine increased waveform duration at the thoracic inlet. Acepromazine administration increased the number of spontaneous events at the thoracic inlet and distal portion of the esophagus. Acepromazine and detomidine administration increased the number of high-pressure events at the thoracic inlet. Guaifenesin administration increased the number of spontaneous events at the thoracic inlet. Xylazine-butorphanol, detomidine, acepromazine, and guaifenesin administration decreased the number of spontaneous swallows. Conclusions and Clinical Relevance-Detomidine, acepromazine, and a combination of xylazine butorphanol had the greatest effect on esophageal motility when evaluated manometrically. Reduction in spontaneous swallowing and changes in normal, coordinated peristaltic activity are the most clinically relevant effects.
Show more [+] Less [-]Effect of a passive heat and moisture exchanger on esophageal temperature in tumor-bearing dogs during whole-body hyperthermia
1991
Meyer, R.E. | Page, R.L. | Thrall, D.E.
The effect of a passive heat and moisture exchanger on tracheal and large airway temperature, as reflected by esophageal temperature at the thoracic inlet, was determined for 12 anesthetized and ventilated tumor-bearing dogs undergoing whole-body hyperthermia at 42 C. Delivered thermal dose to the esophagus and rectum during 120 minutes of whole-body hyperthermia was quantified as the thermal dose summary measure EQ43. The heat and moisture exchanger significantly increased esophageal EQ43 from 7.3 minutes to 12.1 minutes. Esophageal EQ43, however, remained lower than rectal EQ43. Although use of a heat and moisture exchanger improved esophageal temperature during whole-body hyperthermia, presumably through improved airway temperature, additional methods will be necessary to increase esophageal and airway temperature to the target value of 42 C.
Show more [+] Less [-]Ultrastructural localization of pemphigus vulgaris antigen on canine keratinocytes in vivo and in vitro
1990
Suter, M.M. | Wilkinson, J.E. | Dougherty, E.P. | Lewis, R.M.
Pemphigus antigens were localized, by use of immunoelectron microscopy, on canine keratinocytes in vivo on esophageal mucosa and in vitro on established cultured keratinocytes. Convalescent sera from a human being with pemphigus vulgaris and a human being with pemphigus foliaceus reacted with the interdesmosomal cytoplasmic keratinocyte membrane of canine esophagus. Cultured canine keratinocytes expressed the pemphigus vulgaris antigen in a similar pattern, but did not carry the pemphigus foliaceus antigen. The differential presence of cell surface antigens and its relation to various forms of the disease are discussed.
Show more [+] Less [-]Effect of position on transdiaphragmatic pressure and hemodynamic variables in anesthetized horses
2020
Youngblood, Cori D. | Hodgson, David S. | Beard, Warren L. | Song, Yuqi | Prakash, Punit | Heflin, Lindsay V.
Recumbency affects respiratory mechanics and oxygenation in anesthetized horses. Changes in pleural and abdominal pressures that can impair ventilation have not been described in all recumbencies. The objective of this study was to determine the effects of patient positioning on transdiaphragmatic pressure and selected hemodynamic variables. Horses were maintained under total intravenous general anesthesia with nasal oxygen supplementation. Transnasal balloon catheters in the stomach and thoracic esophagus were used to measure intrathoracic and gastric pressures in standing horses and in anesthetized horses positioned in right and left lateral recumbency, dorsal recumbency, reverse Trendelenburg position, and Trendelenburg position. Transdiaphragmatic pressure was calculated as the difference between gastric and intrathoracic pressures. Measurements of oxygen saturation (SpO(2)), heart rate, systolic, diastolic and mean arterial pressures, and respiratory rate were obtained every 5 minutes. When compared to dorsal recumbency, gastric expiratory pressure is decreased in the standing position. Thoracic expiratory pressure is decreased in standing and reverse Trendelenburg. Transdiaphragmatic expiratory pressure and SpO(2) are decreased in Trendelenburg. Heart rate is increased in reverse Trendelenburg. Systolic, diastolic, and mean arterial pressures are decreased in reverse Trendelenburg and increased in left lateral and right lateral recumbency. We found that there is wide variation in respiratory pressures between horses and positions and they are not predictive of associated changes in hemodynamic variables.
Show more [+] Less [-]Esophageal insufflation computed tomography in clinically normal dogs
2019
Hong, Sungkyun | Lee, Siheon | Choen, Sangkyung | Hwang, Jaewoo | Yoon, Junghee | Choi, Mincheol
OBJECTIVE To assess the feasibility of esophageal insufflation CT (EICT) for evaluation of the esophagus in dogs. ANIMALS 7 clinically normal adult Beagles. PROCEDURES Each dog was anesthetized twice with 1 week between anesthesia sessions. Dogs were positioned in sternal recumbency during all CT scans. During the first anesthesia session, a CT scan was performed before the esophagus was insufflated (insufflation pressure, 0 mm Hg) and unenhanced and contrast-enhanced EICT scans were performed after CO(2) was insufflated into the esophageal lumen to achieve a pressure of 5 mm Hg. For the contrast-enhanced scan, each dog received iohexol (600 mg/kg, IV), and the scan was performed 30 seconds later. During the second anesthesia session, unenhanced and contrast-enhanced EICT scans were performed in the same manner except the insufflation pressure achieved was 10 mm Hg. The esophageal luminal cross-sectional area and wall thickness were measured at each of 5 segments, and mean values were compared among the 3 insufflation pressures and between unenhanced and contrast-enhanced images. RESULTS Mean esophageal luminal cross-sectional area increased and esophageal wall thickness decreased as insufflation pressure increased. Measurements did not differ significantly between unenhanced and contrast-enhanced images. The stomach became distended with CO(2) at an insufflation pressure of 10 mm Hg but not at 5 mm Hg. No adverse effects were observed. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested EICT was feasible for esophageal evaluation in dogs. Further research is necessary to determine the optimal insufflation pressure for the procedure and its diagnostic efficacy in diseased patients.
Show more [+] Less [-]Evaluation of gastroscopy and biopsy of the proventriculus and ventriculus in pigeons (Columba livia)
2017
Sladakovic, Izidora | Ellis, Angela E. | Divers, Stephen J.
OBJECTIVE To evaluate the efficacy and safety of gastroscopy and biopsy of the proventriculus and ventriculus in pigeons (Columba livia). ANIMALS 15 adult pigeons. PROCEDURES Each pigeon was anesthetized, and the upper gastrointestinal tract (from the cervical portion of the esophagus to the ventriculus) was endoscopically evaluated by use of a rigid endoscope inserted orally. Saline (0.9% NaCl) solution was orally infused to achieve lumen dilation and visibility. Two mucosal biopsy specimens were collected from each of the proventriculus and ventriculus, histologically evaluated, and graded for crush artifacts and depth. Pigeons were monitored for adverse effects for 3 to 6 days after the procedure, after which they were euthanized for necropsy. RESULTS Gastroscopy via the oral approach provided excellent visibility of the lumen and mucosal surfaces of the proventriculus and cranial portion of the ventriculus and was safe provided that appropriate precautions were taken. Two intraoperative deaths occurred at the beginning of the study; following procedure refinement, no additional deaths occurred. No major adverse effects of the procedure were detected in the remaining 13 pigeons during the postoperative monitoring period or at necropsy. Diagnostic quality of proventriculus specimens was adequate for 10 of 13 pigeons. Eight of 13 ventriculus specimens were of inadequate quality, and only 3 were of adequate quality. CONCLUSIONS AND CLINICAL RELEVANCE Gastroscopy was useful for evaluating the lumen and mucosal surface of the proventriculus and ventriculus in pigeons, and biopsy of those organs was safely performed with the appropriate technique. Further evaluation of these techniques is needed in birds with clinical disease and birds of other species.
Show more [+] Less [-]Development of a technique for contrast radiographic examination of the gastrointestinal tract in ball pythons (Python regius)
2012
Banzato, Tommaso | Russo, Elisa | Finotti, Luca | Zotti, Alessandro
Objective: To develop a technique for radiographic evaluation of the gastrointestinal tract in ball pythons (Python regius). Samples: 10 ball python cadavers (5 males and 5 females) and 18 healthy adult ball pythons (10 males and 8 females). Procedures: Live snakes were allocated to 3 groups (A, B, and C). A dose (25 mL/kg) of barium sulfate suspension at 3 concentrations (25%, 35%, and 45% [wt/vol]) was administered through an esophageal probe to snakes in groups A, B, and C, respectively. Each evaluation ended when all the contrast medium had reached the large intestine. Transit times through the esophagus, stomach, and small intestine were recorded. Imaging quality was evaluated by 3 investigators who assigned a grading score on the basis of predetermined criteria. Statistical analysis was conducted to evaluate differences in quality among the study groups. Results: The esophagus and stomach had a consistent distribution pattern of contrast medium, whereas 3 distribution patterns of contrast medium were identified in the small intestine, regardless of barium concentration. Significant differences in imaging quality were detected among the 3 groups. Conclusions and Clinical Relevance: Radiographic procedures were tolerated well by all snakes. The 35% concentration of contrast medium yielded the best imaging quality. Use of contrast medium for evaluation of the cranial portion of the gastrointestinal tract could be a reliable technique for the diagnosis of gastrointestinal diseases in ball pythons. However, results of this study may not translate to other snake species because of variables identified in this group of snakes.
Show more [+] Less [-]