Refine search
Results 1-8 of 8
Use of indocyanine green and sodium fluorescein for anterior segment angiography in ophthalmologically normal cats
2015
Pirie, Chris G. | Alario, Anthony
OBJECTIVE To assess and compare results of anterior segment angiography of ophthalmologically normal cats following IV injection with indocyanine green and sodium fluorescein dyes. ANIMALS 10 client-owned cats. PROCEDURES Anterior segment angiography was performed in anesthetized cats following administration of 0.25% indocyanine green (1.0 mg/kg, IV) or 10% sodium fluorescein (20 mg/kg, IV) solution. All cats received both treatments. Imaging (1 eye/cat) was performed with a full-spectrum digital single-lens reflex camera equipped with an adaptor (1 image/s for 30 seconds) immediately following IV dye injection and 1, 2, 3, 4, and 5 minutes after injection. Onset and duration of arterial, capillary, and venous phases of iris vasculature were identified and compared statistically between treatments. Degree of iridal pigmentation, leakage of dye from iris vasculature, and image quality were subjectively assessed. RESULTS No differences were found in onset or duration of vascular phases between treatments. Visibility of the iris vasculature was not impaired by poor or moderate iridal pigmentation with either method. Indocyanine green provided subjectively better vascular detail and image contrast than sodium fluorescein. No vascular dye leakage was observed following indocyanine green administration. Leakage of dye from blood vessels in the stroma (in 10 cats) and presence of dye in the anterior chamber (in 5 cats) were detected after sodium fluorescein administration. CONCLUSIONS AND CLINICAL RELEVANCE Images obtained with either fluorescent dye were considered to be of diagnostic quality. Lack of leakage following indocyanine green administration suggested this treatment may have better diagnostic utility for anterior segment angiography. The photographic equipment used provided a cost-effective alternative to existing imaging systems.
Show more [+] Less [-]Intraocular pressure in clinically normal dromedary camels (Camelus dromedarius)
2015
Marzok, Mohamed A. | El-khodery, Sabry A.
OBJECTIVE To determine the intraocular pressure (IOP) in healthy dromedary camels (Camelus dromedarius). ANIMALS 24 clinically normal dromedary camels. PROCEDURES For each camel, the IOP of both eyes was measured with applanation tonometry. Three measurements with < 5% variance were obtained for each eye on the same day of the week for 3 consecutive weeks. Mean IOP was calculated for each eye on each day for comparison purposes. RESULTS Mean ± SD IOPs for the right (31.1 ± 2.1 mm Hg) and left (30.8 ± 1.9 mm Hg) eyes of immature camels were significantly higher than those for the right (27.1 ± 1.2 mm Hg) and left (28.2 ± 1.2 mm Hg) eyes of mature camels. Intra-assay and interassay coefficients of variation (CVs) for IOP measurements of the right and left eyes did not differ significantly between immature and mature camels. Interassay CVs of IOP measurements for the right and left eyes ranged from 1.5% to 12.1% and 1.2% to 10.3%, respectively, for immature camels and from 1.2% to 17.2% and 1.7% to 18.8%, respectively, for mature camels. Intra-assay CVs of IOP measurements for the right and left eyes ranged from 1.5% to 10.6% and 1.9% to 9.6%, respectively, for immature camels and from 2.8% to 16.9% and 2.7% to 12.4%, respectively, for mature camels. Age was negatively correlated (r = −0.403) with IOP. CONCLUSIONS AND CLINICAL RELEVANCE Results provided a reference and might aid in the diagnosis of glaucoma and uveitis during complete ophthalmic examinations of dromedary camels.
Show more [+] Less [-]Comparison of two- and three-times-daily topical ophthalmic application of 0.005% latanoprost solution in clinically normal dogs
2015
Tofflemire, Kyle L. | Whitley, Elizabeth M. | Allbaugh, Rachel A. | Ben-Shlomo, Gil | Robinson, Casey C. | Overton, Taryn L. | Thiessen, Charlotte E. | Evans, Erin A. | Griggs, Angel N. | Adelman, Sara A. | Ludwig, Allison L. | Jens, Jackie K. | Ellinwood, N Matthew | Peterson, Chimene S. | Whitley, R David
OBJECTIVE To determine whether 2- or 3-times-daily application of topical ophthalmic 0.005% latanoprost solution is more effective at lowering intraocular pressure (IOP) in clinically normal dogs. ANIMALS 9 clinically normal dogs. PROCEDURES For each dog, I drop of latanoprost 0.005% solution was applied to 1 eye every 8 or 12 hours each day for 5 days; the contralateral eye received topical ophthalmic treatment with 1 drop of saline (0.9% NaCl) solution at the times of latanoprost application. Ocular examinations of both eyes were performed every 6 hours starting 48 hours prior to and ending 42 hours after the treatment period. Following a 5-week washout interval, the procedures were repeated but the previously latanoprost-treated eye of each dog received latanoprost application at the alternate frequency. RESULTS Mean ± SD IOP reduction in the latanoprost-treated eyes was 31 ± 6.9% with 2-times-daily application and 33 ± 8.2% with 3-times-daily application. A 2-way repeated-measures ANOVA revealed significant differences in IOP with contributions by treatment (2 or 3 times daily), time of day (diurnal variation), and individual dog. The maximum mean daily IOP reduction in latanoprost-treated eyes was detected on day 3 of latanoprost treatment in each group. Eyes treated 3 times daily had significantly smaller pupil diameter and greater conjunctival hyperemia than eyes treated 2 times daily. CONCLUSIONS AND CLINICAL RELEVANCE The clinical importance of the ocular hypotensive effects of 3-times-daily topical ophthalmic application of 0.005% latanoprost solution in dogs with glaucoma warrants investigation.
Show more [+] Less [-]Tear film osmolality and electrolyte composition in healthy horses
2015
Best, Lori J. | Hendrix, Diane V. H. | Ward, Daniel A.
OBJECTIVE To evaluate the tear film osmolality and electrolyte composition in healthy horses. ANIMALS 15 healthy adult horses. PROCEDURES Each horse was manually restrained, and an ophthalmic examination, which included slit-lamp biomicroscopy, indirect ophthalmoscopy, and a Schirmer tear test, was performed. Tear samples were collected from both eyes with microcapillary tubes 3 times at 5-minute intervals. The tear samples for each horse were pooled, and the osmolality and electrolyte concentrations were measured. The mean (SD) was calculated for each variable to establish preliminary guidelines for tear film osmolality and electrolyte composition in healthy horses. RESULTS The mean (SD) tear film osmolality was 283.51 (9.33) mmol/kg, and the mean (SD) sodium, potassium, magnesium, and calcium concentrations were 134.75 (10), 16.3 (5.77), 3.48 (1.97), and 1.06 (0.42) mmol/L, respectively. The sodium concentration in the tear film was similar to that in serum, whereas the potassium concentration in the tear film was approximately 4.75 times that of serum. CONCLUSIONS AND CLINICAL RELEVANCE Results provided preliminary guidelines with which tear samples obtained from horses with keratopathies can be compared. Measurement of tear film osmolality in these horses was easy and noninvasive. The tear film concentration of divalent cations was greater than expected and was higher than the divalent cation concentrations in the tear films of rabbits and humans. These data may be clinically useful for the diagnosis and monitoring of hyperosmolar ocular surface disease in horses.
Show more [+] Less [-]Measurement of intraocular pressure in healthy unanesthetized inland bearded dragons (Pogona vitticeps)
2015
Schuster, Eva J. | Strueve, Julia | Fehr, Michael J. | Mathes, Karina A.
OBJECTIVE To evaluate the use of rebound and applanation tonometry for the measurement of intraocular pressure (IOP) and to assess diurnal variations in and the effect of topical anesthesia on the IOP of healthy inland bearded dragons (Pogona vitticeps). ANIMALS 56 bearded dragons from 4 months to 11 years old. PROCEDURES For each animal following an initial ophthalmic examination, 3 IOP measurements were obtained on each eye between 9 AM and 10 AM, 1 PM and 2 PM, and 5 PM and 7 PM by use of rebound and applanation tonometry. An additional measurement was obtained by rebound tonometry for each eye in the evening following the application of a topical anesthetic to evaluate changes in the tolerance of the animals to the tonometer. Descriptive data were generated, and the effects of sex, time of day, and topical anesthesia on IOP were evaluated. RESULTS Bearded dragons did not tolerate applanation tonometry even following topical anesthesia. Median daily IOP as determined by rebound tonometry was 6.16 mm Hg (95% confidence interval, 5.61 to 6.44 mm Hg). The IOP did not differ significantly between the right and left eyes. The IOP was highest in the morning, which indicated that the IOP in this species undergoes diurnal variations. Topical anesthesia did not significantly affect IOP, but it did improve the compliance for all subjects. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that rebound tonometry, but not applanation tonometry, was appropriate for measurement of IOP in bearded dragons. These findings provided preliminary guidelines for IOP measurement and ophthalmic evaluation in bearded dragons.
Show more [+] Less [-]Relationship between intracranial pressure as measured by an epidural intracranial pressure monitoring system and optic nerve sheath diameter in healthy dogs
2015
llie, Laura A. | Thomovsky, Elizabeth J. | Johnson, Paula A. | Bentley, Tim | Heng, Hock Gan | Lee, Hee C. | Moore, George E.
OBJECTIVE To evaluate the association between ultrasonographically measured optic nerve sheath diameter (ONSD) and acute increases in intracranial pressure (ICP) as measured by an epidural intracranial pressure monitoring system (EICPMS) in healthy dogs. ANIMALS 6 young healthy dogs. PROCEDURES An EICPMS connected to a pressure monitor was used to generate a continuous pressure waveform in each anesthetized dog. A 22-gauge IV catheter was inserted into the brain parenchyma through the contralateral parietal bone, and 0.5 to 2.0 mL of anticoagulated autologous blood was injected at predetermined intervals. At baseline (immediately after EICPMS placement) and following each injection, the ICP as indicated by EICPMS was recorded, and 3 ultrasonographic images of the optic nerve sheath of each eye were obtained. The ONSD was measured at maximum diameter and at 5 mm caudal to the optic disk. RESULTS In linear models, the maximum ONSD was positively associated with increasing ICP. Specifically, the rate of maximum ONSD increase was greater for pressures ≤ 20 mm Hg above baseline (0.0534 mm/1 mm Hg ICP increase) than for pressures > 40 mm Hg above baseline (0.0087 mm/1 mm Hg ICP increase). The relationship of ICP to maximum ONSD was slightly nonlinear and best explained by comparison of fractional polynomial regression models. CONCLUSIONS AND CLINICAL RELEVANCE ICP was positively and nonlinearly associated with increasing maximum ONSD, especially when ICP was ≤ 20 mm Hg above baseline, supporting the conclusion that ultrasonographic measurement of maximum ONSD may provide a noninvasive monitoring tool for evaluation of ICP in dogs. Further research is needed to assess the utility of these measurements in clinical patients.
Show more [+] Less [-]Comparison of ultrasound biomicroscopy and standard ocular ultrasonography for detection of canine uveal cysts
2015
Taylor, LaTisha N. | Townsend, Wendy M. | Heng, Hock Gan | Stiles, Jean | Moore, George E.
OBJECTIVE To compare ultrasound biomicroscopy (UBM) with standard ocular ultrasonography for detection of canine uveal cysts and to determine the sensitivity, specificity, and interobserver agreement for detection of uveal cysts with UBM. SAMPLE 202 enucleated eyes from 101 dogs. PROCEDURES 2 examiners examined 202 eyes by means of UBM (50 MHz) to identify uveal cysts. A board-certified radiologist then examined 98 of the 202 eyes by means of standard ocular ultrasonography (7- to 12-MHz linear transducer). Subsequently, 1 examiner dissected all 202 eyes under magnification from an operating microscope to definitively identify uveal cysts. Each examiner was masked to other examiners’ findings. Sensitivity, specificity, and interobserver agreement were calculated for detection of cysts by UBM. RESULTS Cysts were detected by use of UBM in 55 of 202 (27%) eyes by one examiner and 29 of 202 (14%) eyes by the other. No cysts were detected in the 98 eyes examined with standard ocular ultrasonography. Dissection results revealed that cysts were present in 64 of 202 (32%) eyes, including 29 of 98 (30%) eyes examined by standard ocular ultrasonography. Mean sensitivity of UBM for cyst detection was 47%; mean specificity was 92%. Uveal cysts not identified with UBM were often small (mean diameter, 490 üm). Interobserver agreement was high (κP = 0.81). CONCLUSIONS AND CLINICAL RELEVANCE UBM was more effective than standard ocular ultrasonography for detection of uveal cysts in enucleated eyes. Small-diameter cysts were difficult to visualize even with UBM.
Show more [+] Less [-]Effects of premedication with sustained-release buprenorphine hydrochloride and anesthetic induction with ketamine hydrochloride or propofol in combination with diazepam on intraocular pressure in healthy sheep
2015
Gatson, Bonnie J. | Pablo, Luisito | Plummer, Caryn E. | Granone, Tiffany D.
OBJECTIVE To determine the effects of diazepam combined with ketamine hydrochloride or propofol for induction of anesthesia (IOA) following premedication with sustained-release buprenorphine hydrochloride (SRB) on intraocular pressure (IOP) in sheep. ANIMALS 20 healthy adult sheep. PROCEDURES Diazepam with ketamine or propofol was given IV to each of 10 sheep after premedication with SRB (0.01 mg/kg, SC); after > 4 weeks, each sheep received the other induction combination with no premedication. For both eyes, IOPs were measured before premedication (if given), 10 minutes prior to (baseline) and immediately following administration of ketamine or propofol (time of IOA), after endotracheal intubation, and 5 minutes after IOA. Peak end-tidal Pco2, globe position, and pupillary diameter were also analyzed. RESULTS Data were not available for all sheep for all anesthetic episodes. Propofol-diazepam administration alone had no significant effect on IOP, whereas there was a significant decrease in IOP immediately following ketamine-diazepam administration alone. At 5 minutes after ketamine-diazepam administration, SRB-premedicated sheep had significantly higher IOP than unpremedicated sheep. Intraocular pressure was significantly higher at baseline, at intubation, and 5 minutes after IOA in SRB-premedicated sheep receiving propofol-diazepam, compared with unpremedicated sheep. Peak end-tidal Pco2 at intubation was significantly higher in SRB-premedicated sheep. For sheep receiving either anesthetic treatment, IOPs did not differ significantly with or without SRB premedication. Globe position or pupillary diameter and IOP were not significantly related at any time point. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that both ketamine-diazepam and propofol-diazepam combinations were suitable for IOA without increasing IOP in sheep. The use of SRB should be avoided in sheep when increases in IOP are undesirable.
Show more [+] Less [-]