Dynamic viscoelastic coagulometry of blood obtained from healthy chickens
2019
Rodenbaugh, Cassandra I. | Lyon, Shane D. | Hanzlicek, Andrew S. | Kanda, Ian | Payton, Mark E. | Rizzi, Theresa E. | Holland, LaRinda A. | Brandao, Joao
OBJECTIVE To assess feasibility of the use of a dynamic viscoelastic coagulometer on chicken blood and compare coagulation variables for fresh whole blood and sodium citrate–preserved whole blood as well as effects of 3 coagulation activators on blood from chickens. SAMPLE Blood samples from 30 hens. PROCEDURES Chickens were allowed to rest undisturbed for 1 hour. A blood sample was collected from an ulnar vein; 1.4 mL was analyzed immediately, and 1.8 mL was mixed with sodium citrate and subsequently recalcified and analyzed. A separate coagulation activator (glass beads, kaolin clay, or tissue factor) was in each of the 2 channels of the analyzer. Chickens were allowed a 1-hour rest period, and another blood sample was collected from the contralateral ulnar vein; it was processed in the same manner as for the first sample, except both channels of the analyzer contained the same coagulation activator. RESULTS Compared with fresh samples, citrated samples had higher values for activated clotting time and platelet function and lower clotting rates. Intra-assay coefficients of variation of coagulation profiles for citrated samples were markedly greater than the limit of 10%, whereas values for fresh samples were close to or < 10%. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that use of a dynamic viscoelastic coagulometer on chicken blood was feasible and that analysis of fresh whole blood from healthy chickens provided results with less variability than did analysis of citrated blood. Samples preserved with sodium citrate were associated with significant relative hypocoagulability, compared with results for fresh blood.
Show more [+] Less [-]Effects of syringe type and storage conditions on results of equine blood gas and acid-base analysis
2012
Kennedy, Sarah A. | Constable, Peter D. | Şen, İsmail | Couetil, Laurent
Objective: To determine effects of syringe type and storage conditions on blood gas and acid-base values for equine blood samples. Sample: Blood samples obtained from 8 healthy horses. Procedures: Heparinized jugular venous blood was equilibrated via a tonometer at 37°C with 12% O2 and 5% CO2. Aliquots (3 mL) of tonometer-equilibrated blood were collected in random order by use of a glass syringe (GS), general-purpose polypropylene syringe (GPPS), or polypropylene syringe designed for blood gas analysis (PSBGA) and stored in ice water (0°C) or at room temperature (22°C) for 0, 5, 15, 30, 60, or 120 minutes. Blood pH was measured, and blood gas analysis was performed; data were analyzed by use of multivariable regression analysis. Results: Blood Po2 remained constant for the reference method (GS stored at 0°C) but decreased linearly at a rate of 7.3 mm Hg/h when stored in a GS at 22°C. In contrast, Po2 increased when blood was stored at 0°C in a GPPS and PSBGA or at 22°C in a GPPS; however, Po2 did not change when blood was stored at 22°C in a PSBGA. Calculated values for plasma concentration of HCO3 and total CO2 concentration remained constant in the 3 syringe types when blood was stored at 22°C for 2 hours but increased when blood was stored in a GS or GPPS at 0°C. Conclusions and Clinical Relevance: Blood samples for blood gas and acid-base analysis should be collected into a GS and stored at 0°C or collected into a PSBGA and stored at room temperature.
Show more [+] Less [-]