Refine search
Results 1-10 of 15
Acute effect of hydralazine administration on pulmonary artery hemodynamics in dogs with chronic heartworm disease
1994
Atkins, C.E. | Keene, B.W. | McGuirk, S.M. | Satō, Tōru
In an effort to better understand the role of vasodilators in the management of pulmonary hypertension associated with chronic heartworm disease (HWD), pulmonary hemodynamic measurements were obtained from 7 experimentally infected, anesthetized dogs before and after hydralazine administration (mean dose, 1.96 mg/kg of body weight). Five dogs were maintained on room air, while 2 were maintained on 100% oxygen during the hydralazine study. The hemodynamic effect of hydralazine in dogs with HWD was evaluated, using heart rate, cardiac index, mean pulmonary artery pressure, mean arterial pressure, total pulmonary resistance, total systemic resistance, total systemic resistance/total pulmonary resistance, left ventricular dP/dt(max), left ventricular end diastolic pressure, and left and right ventricular double products ([mean arterial pressure X heart rate] and [mean pulmonary artery pressure X heart rate], respectively). Responders were defined as those in which total pulmonary resistance decreased greater than or equal to 20% without an increase in mean pulmonary arterial pressure and in which heart rate increase was less than or equal to 10%. Comparison was also made between maximal hemodynamic effect of hydralazine with that after 100% oxygen administration for 15 minutes to previously normoxemic dogs (n = 5). Significance was determined if P < 0.05, using the paired t-test. Hydralazine induced significant reductions in mean pulmonary and systemic arterial pressures and total pulmonary resistance, with no significant change in heart rate, cardiac index, total systemic resistance, left ventricular dP/dt(max), left ventricular end diastolic pressure, or right and left ventricular double products. Four (57%) of the 7 dogs studied were considered responders. Pretreatment cardiac index, mean pulmonary artery pressure, and total pulmonary resistance did not allow differentiation of responders from nonresponders. However, pretreatment right ventricular end diastolic pressure was significantly less in responders than in nonresponders. Two dogs sustained hypotension after hydralazine administration, but no dogs had significant tachycardia. In dogs with experimentally induced HWD, treatment with hydralazine had significantly greater effect on cardiac index and mean pulmonary and systemic arterial pressures and resistance than did administration of 100% oxygen. These data indicate that further study of vasodilators for treatment of HWD-induced pulmonary hypertension may be warranted.
Show more [+] Less [-]Characterization of the hemodynamic and metabolic alterations in the large colon of horses during low-flow ischemia and reperfusion
1994
Moore, R.M. | Muir, W.W. | Bertone, A.L. | Beard, W.L.
Effects of low-flow ischemia and reperfusion of the large colon on systemic and colonic hemodynamic and metabolic variables were determined in horses. Twenty-four adult horses were randomly allocated to 3 groups: sham-operated (n = 6), 6 hours of ischemia (n = 9), and 3 hours of ischemia and 3 hours of reperfusion (n = 9). Low-flow ischemia was induced in groups 2 and 3 by reducing colonic arterial blood flow to 20% of baseline. Heart rate, arterial blood pressures, cardiac index, pulmonary artery pressure, right atrial pressure, and colonic blood flow were monitored. Arterial, mixed-venous, and colonic venous blood gas and oximetry analyses; PCV; and blood lactate and pyruvate and plasma total protein concentrations were measured. Data were recorded, and blood samples were collected at baseline and at 30-minute intervals for 6 hours; additionally, data were collected at 185, 190, and 195 minutes (corresponding to 5, 10, and 15 minutes of reperfusion in group-3 horses). There were no differences among groups at baseline or across time for any systemic hemodynamic or metabolic variable. Colonic blood flow did not change across time in group-1 horses. Colonic blood flow significantly (P < 0.05) decreased to 20% of baseline at induction of ischemia in horses of groups 2 and 3 and remained significantly decreased throughout the ischemic period in horses of groups 2 (6 hours) and 3 (3 hours). Colonic blood flow significantly (P < 0.05) increased above baseline by 5 minutes of reperfusion in group-3 horses. Colonic oxygen delivery and oxygen consumption, and colonic venous pH, PO2, percentage saturation of hemoglobin, and oxygen content were significantly (P < 0.05) decreased within 30 minutes after induction of ischemia in horses of groups 2 and 3; colonic venous PCO2, colonic oxygen extraction ratio, and lactate and pyruvate concentrations were significantly (P < 0.05) increased by 30 minutes of ischemia. These alterations continued throughout ischemia, but within 5 minutes of reperfusion in group-3 horses, these variables either returned to baseline (pH, PCO2, lactate, pyruvate), significantly (P < 0.05) increased above baseline (PO2, oxygen content, % saturation of hemoglobin), or significantly (P < 0.05) decreased below baseline (colonic oxygen extraction ratio). Colonic oxygen consumption remained decreased during reperfusion in group-3 horses. Colonic mucosal ischemia-reperfusion injury observed in this model of ischemia was associated with local colonic hemodynamic and metabolic alterations in the presence of systemic hemodynamic and metabolic stability. Reactive hyperemia was observed at restoration of colonic blood flow in group-3 horses and persisted during reperfusion. Colonic venous metabolic alterations were corrected at reperfusion, indicating adaptation of the colon to the return of blood flow and oxygen delivery with resultant decrease in anaerobic metabolism. The early alterations in these variables may simply represent a washout of metabolic by-products.
Show more [+] Less [-]Rate of change of QT interval in response to a sudden change in the heart rate in dogs
1994
Oguchi, Y. | Hamlin, R.L.
Although it is known that the QT interval is dependent on the preceding RR interval, QT interval does not vary during respiratory sinus arrhythmia, despite a wide variation in heart rate. To assess the rate of change of the QT interval following an abrupt increase or decrease in heart rate, QT intervals were measured from ECG of healthy, anesthetized, thoracotomized dogs in which a junctional rhythm had been induced by destroying the sinoatrial node. Atria were paced at 800- or 600-millisecond cycle durations until a steady state was reached, and then the cycle duration was changed suddenly to a new cycle duration (600 or 800 milliseconds, respectively). The time and number of heart beats required until the QT interval achieved a value of 63% (1 time constant) of the new steady state were calculated. Time constants for change in QT interval vs the number of beats following the change were 2.8 (SD = 1.3 s) seconds when heart rate was accelerated and 4.7 (SD = 2.1 s) seconds when heart rate was slowed. Differences were not statistically significant. The time constants for change in QT interval duration vs duration after the sudden change in heart rate were 1.7 (SD = 0.8 s) seconds when heart rate was accelerated and 3.7 (SD = 1.7 s) seconds when heart rate was slowed. These time constants differed significantly (P < 0.01). Response of QT interval, therefore, depended on the number of heart beats following sudden change in heart rate, but not time, except as time determined the number of heart beats. The QT interval did not change until 3 to 5 beats after the heart rate was suddenly changed. This number of beats would be more than that which would occur in 1 respiratory cycle in dogs; therefore, QT interval memory would prohibit changes in QT intervals that occur during respiratory sinus arrhythmia.
Show more [+] Less [-]Cardiopulmonary effects of medetomidine in heartworm-infected and noninfected dogs
1994
Venugopalan, C.S. | Holmes, E.P. | Fucci, V. | Keefe, T.J. | Crawford, M.P.
Medetomidine, an investigational drug indicated for clinical use as a short-term chemical restraint in dogs, was evaluated for its cardiopulmonary effects, in 10 naturally heartworm-infected (HW+) and 10 noninfected (HW-) Beagles. The drug was randomly administered IV (30 microgram/kg of body weight) and IM (40 microgram/kg) in single injections to all dogs. Heart rate, respiratory rate, ECG, blood gas tensions, blood pH, central venous and arterial pressures were measured at 0, 15, 30, 60, 90, 120, and 180 minutes. Medetomidine induced an immediate significant (P less than or equal to 0.001) increase in mean arterial blood pressure followed by decreased blood pressure that remained below normal throughout the study in both groups, irrespective of route of administration. Medetomidine increased central venous pressure, over time, for both groups and both routes of administration. Heart and respiratory rates were significantly (P less than or equal 0.001) decreased after medetomidine administration and remained reduced for the duration of the study in all dogs. The ECG variables were not significantly different between groups or between routes of administration. The HW+ dogs tended to have higher mean PaO2 than did HW- dogs at several postinjection determination times, particularly when the drug was administered IM. The PaO2 decreased during the first 30 minutes in both groups and tended to increase gradually thereafter. The pH decreased over time for both groups and both routes. A significant (P less than or equal to 0.05) decrease in pH was seen in the HW- dogs, compared with HW+ dogs at each measuring time for both routes. The PaCO2 did not significantly change for groups or routes. In general, bradycardia was the predominant cardiovascular effect seen after medetomidine administration in all dogs, irrespective of route. Lowering of blood pressure and heart rate (after a transient blood pressure increase) was synchronized with sedation in these dogs. The overall clinical response with regard to cardiopulmonary effects in HW+ dogs was similar to that in HW- dogs.
Show more [+] Less [-]Plasma concentration of atrial natriuretic peptide in relation to severity of mitral regurgitation in Cavalier King Charles Spaniels
1994
Haggstrom, J. | Hansson, K. | Karlberg, B.E. | Kvart, C. | Olsson, K.
Plasma concentration of immunoreactive atrial natriuretic peptide (ir-ANP) was investigated in 83 Cavalier King Charles Spaniels with variable severity of mitral regurgitation caused by chronic valvular disease (CVD). Severity of mitral incompetence was assessed by echocardiography. Significant differences in plasma concentrations of ir-ANP were not found between clinically normal dogs (New York Heart Association functional class O), dogs with only cardiac murmur (class I), and dogs with echocardiographic evidence of slight to moderate left atrial and ventricular dilatation (class II). Dogs with severe left atrial and ventricular dilatation and clinical signs of congestion (classes III and IV) were found to have significantly (P < 0.001) increased plasma concentration of ir-ANP. Overall, moderate degree of association was found between plasma concentration of ir-ANP and left atrial and left ventricular diameters (Pearson's r = 0.65, 0.60, respectively, P < 0.001), as well as heart rate (r = 0.47, P < 0.01). However, left atrial enlargement as found to have the predominant effect on plasma ir-ANP concentration. It is concluded that the plasma concentration of ir-ANP did not become markedly increased before decompensation of chronic mitral regurgitation associated with severe enlargement of the left atrium and ventricle in Cavalier King Charles Spaniels.
Show more [+] Less [-]Tidal breathing flow-volume loop analysis as a test of pulmonary function in exercising horses
1994
Connally, B.A. | Derksen, F.J.
The usefulness of tidal breathing flow-volume loops (TBFVL) to evaluate pulmonary function was investigated in 6 Standardbreds during treadmill exercise. Tidal breathing flow-volume loops are a graphic representation of airflow rate vs tidal volume for each individual breath. These TBFVL were obtained from horses exercising it speeds corresponding to 75 and 100% of maximum heart rate. Measurements were recorded in each horse before and after ovalbumininduced allergic lung disease. Moderate obstructive lung disease, characterized by a significant increase in pulmonary resistance, was observed while the horses were at rest. We found that in horses with airway obstruction exercising at 75 or 100% of maximum heart rate, the quantitative indices describing TBFVL shape and size were not markedly different from those in clinically normal horses exercising at similar speeds.
Show more [+] Less [-]Evaluation of a dosing method for studying ergonovine effects in cattle
1994
Oliver, J.W. | Linnabary, R.D. | Abney, L.K. | Van Manen, K.R. | Knoop, R. | Adair, H.S. III.
We evaluated the feasibility of using miniosmotic pumps as a way to continuously treat cattle with a singular ergot alkaloid (ergonovine) of known content, thus mimicking the natural fescue toxicosis disease state, but allowing study of specific alkaloid effects. Dosing animals with increasing amounts of ergonovine via miniosmotic pumps, followed by daily acquisition of plasma samples for high-performance liquid chromatographic determination of the alkaloid, resulted in stepwise increases in plasma ergonovine concentration. However, despite the detectable blood concentration of ergonovine, calves did not have typical clinical signs of ergot alkaloid toxicosis. Similarly, serum prolactin concentration was unaffected by ergonovine in these cattle, implicating some other alkaloid of endophyte-infested fescue as causative of the usual prolactin-suppressive response. The results confirm use of this animal dosing method to study biological effects of singular purified alkaloids of known amount, without bioavailability concerns. Thus, this dosing method will facilitate studies to determine the harmful effects of individual alkaloids found in toxic tall fescue, and ultimately, to alleviate their costly effects in cattle, horses, and other species.
Show more [+] Less [-]Effect of body direction on heart rate in trailered horses
1994
Smith, B.L. | Jones, J.H. | Carlson, G.P. | Pascoe, J.R.
To determine whether body direction in a trailer affects the degree to which a horse is excited (and presumably stressed) during transport, heart rates were measured in 8 Thoroughbred geldings transported over a 32-km route of county roads while tethered facing forward or backward in a 4-horse stock trailer. Heart rates also were measured on the horses while they were tethered facing forward or backward in the same trailer while it was parked. Heart rates decreased during the first 10 minutes for both groups, and remained stable after the first 15 minutes. Heart rates were not significantly different between horses facing forward or backward during transport or while parked. Heart rates were significantly (P < 0.05) higher for horses during transport, compared with those of horses in a parked trailer whether facing forward or backward.
Show more [+] Less [-]Use of a conductance catheter to assess the effect of endotoxemia on left ventricular end-systolic pressure-volume relationships in anesthetized swine
1994
Hellyer, P.W.
Effects of endotoxemia on left ventricular contractility and systemic hemodynamics were determined in pentobarbital-anesthetized swine. A multielectrode conductance (volume) catheter and a high-fidelity pressure transducer catheter were passed retrograde into the left ventricle to continuously measure pressure and volume. End-systolic pressure-volume relationships were determined during transient (8 to 10 s) caudal vena caval balloon occlusion. Lactated Ringer's solution was administered at a rate sufficient to maintain left ventricular end-diastolic pressure > 6 mm of Hg. Following baseline measurements, Escherichia coli endotoxin (O55-B5) was infused IV at 2.5 micrograms/kg of body weight/h for 3 hours. Left ventricular end-systolic elastance (Ees), the slope of the end-systolic pressure-volume relationship; end-systolic elastance normalized for left ventricular end-diastolic volume (Ees norm); the rate of increase of left ventricular pressure (dP/dtmax); and preload recruitable stroke work (PRSW, stroke work-to-end-diastolic volume relationship) did not change in endotoxemic swine, compared with baseline measurements or with values from control (physiologic saline solution-treated) swine. Left ventricular pressures and volumes had marked pig-to-pig variability in the control and endotoxin-treated groups. Determination of Ees, Ees norm, and PRSW was further confounded by development of frequent premature ventricular contractions during caudal vena caval balloon occlusion. Endotoxin significantly (P < 0.05) decreased left ventricular end-diastolic pressure, compared with that in control swine, and significantly (P < 0.01) decreased left ventricular end-diastolic volume, compared with baseline. Endotoxin decreased cardiac index and arterial blood pressure, whereas heart rate, central venous pressure, and mean pulmonary arterial pressure increased. Endotoxin did not decrease myocardial contractility, as measured by Ees, Ees norm, dP/dtmax, or PRSW in anesthetized swine.
Show more [+] Less [-]Effects of polymyxin B and Salmonella typhimurium antiserum on horses given endotoxin intravenously
1994
Durando, M.M. | MacKay, R.J. | Linda, S. | Skelley, L.A.
Polymyxin B and an antiserum against an Re mutant Salmonella typhimurium were evaluated for protective effect in an equine model of endotoxemia. Six 3- to 5-month-old foals were given endotoxin (0.25 micrograms/kg of body weight) IV after no pretreatment, or pretreatment with polymyxin B (6,000 U/kg, IV) or S typhimurium antiserum (1.5 ml/kg, IV). When given without pretreatment, endotoxin caused transient recumbency and increases in rectal temperature, and heart and respiratory rates. In addition, leukopenia and increases in circulating tumor necrosis factor (TNF) and interleukin 6 (IL-6) activities were detected. Compared with results obtained when endotoxin was given alone, pretreatment with polymyxin B resulted in significantly (P < 0.05) lower maximal plasma TNF and IL-6 activities, and significantly lower rectal temperature and respiratory rate. In contrast, compared with effects of endotoxin given without pretreatment, use of antiserum was associated with significantly (P < 0.05) higher respiratory rate, maximal plasma IL-6 activity, and total TNF response (as determined by areas under curves of plasma TNF vs time). These results indicate that polymyxin B may have potential as a treatment for equine endotoxemia. Salmonella typhimurium antiserum had no positive effect in this model, and, under certain conditions, may exacerbate the actions of endotoxin.
Show more [+] Less [-]