Refine search
Results 1-10 of 24
Modulation of thermal killing of bovine lymphocytes and preimplantation mouse embryos by alanine and taurine.
1992
Malayer J.R. | Pollard J.W. | Hansen P.J.
Addition of alanine and taurine blocked killing of lymphocytes caused by culture at 45 C. The optimal concentration for thermoprotection was achieved at 12.5 mM for L-alanine and 5 mM for taurine. Both D and L forms of alanine provided thermoprotection. The effect of these agents was not simply to increase osmolarity of the culture medium, because NaCl did not provide thermoprotection at comparable concentrations. Alanine and taurine were each tested at concentration of 50 mM for ability to block heat shock-induced killing and developmental retardation of 8- to 16-cell mouse embryos. Both agents enhanced embryo development after exposure to high temperature, though development remained less than that for embryos not exposed to high temperature. In one experiment, for example, 81% of embryos cultured at 38 C advanced in development during culture vs 0% at 42 C, 15% at 42 C with alanine, and 32% at 42 C with taurine. The beneficial effect of alanine at high temperature may have been partly attributable to effects independent of thermoprotection, because development of embryos cultured at 38 C was also improved by alanine.
Show more [+] Less [-]In vitro effects of a mixture of Escherichia coli heat-stable enterotoxins on chloride flux in everted jejunal sacs of male pigs.
1988
Panichkriangkrai W. | Ahrens F.A.
In vitro effects of a mixture of Escherichia coli heat-stable enterotoxins (STa and STb) on isolated jejunum of 3-week-old male pigs were studied, using everted intestinal sac techniques. Heat-stable enterotoxins increased chloride secretion and chloride absorption in everted intestinal sacs. The increase of secretory flux was greater than that for absorptive flux. Vasoactive intestinal peptide (6 x 10-9M) increased chloride secretion, but had no effect on chloride absorption. Neither vasoactive intestinal peptide nor pilocarpine (10-5M) had additive effect to ST. Secretory effects of ST were not blocked by atropine 2 x 10-5M), clonidine (10-6M), or morphine (4.2 X 10-6M).
Show more [+] Less [-]Histamine contents in raw long-ripening meat products commercially available in Poland Full text
2021
Michalski, Mirosław | Pawul-Gruba, Marzena | Madejska, Anna
Histamine contents in raw long-ripening meat products commercially available in Poland Full text
2021
Michalski, Mirosław | Pawul-Gruba, Marzena | Madejska, Anna
Many consumers seek long-ripening meat products. The availability of these highly distinctive cured pork varieties is continuously expanding and their safety should be subject to monitoring. One of potentially harmful substances in these products is histamine. The presence of this toxic amine is reported in many countries, even in high concentrations. However, the EU has not regulated the permissible histamine content in meat, in a situation at odds with that of regulated fish and fish products. This study established the usefulness of biogenic amine testing in long-ripening pork and furnished indicative concentrations potential useful as a background for future research in preparation for EU regulative intervention. A total of 97 samples of long-ripening meat products untreated by heat were bought from various shops in the Puławy and Lublin regions of Poland and tested for the presence of histamine using high-performance liquid chromatography with diode array. The histamine concentration ranged from below limit of detection to 346.64 mg/kg, where 3.47 mg/kg was the lowest in a positive sample. Histamine was detected in 48 samples (49.5%). The maximum amount of histamine was identified in dry ham and the minimum in traditional salami. The results of this study suggest that testing meat products for biogenic amines should be a very good indicator of the food safety of long-ripening meats. In half of the tested products, levels of biogenic amines potentially toxic to consumers were determined.
Show more [+] Less [-]Histamine contents in raw long-ripening meat products commercially available in Poland Full text
2021
Michalski Mirosław | Pawul-Gruba Marzena | Madejska Anna
Many consumers seek long-ripening meat products. The availability of these highly distinctive cured pork varieties is continuously expanding and their safety should be subject to monitoring. One of potentially harmful substances in these products is histamine. The presence of this toxic amine is reported in many countries, even in high concentrations. However, the EU has not regulated the permissible histamine content in meat, in a situation at odds with that of regulated fish and fish products. This study established the usefulness of biogenic amine testing in long-ripening pork and furnished indicative concentrations potential useful as a background for future research in preparation for EU regulative intervention.
Show more [+] Less [-]Monitoring vaginal electrical resistance, follicular waves, and hormonal profile during oestrous cycle in the transition period in Bangladeshi sheep Full text
2018
Talukder, Mohammad Rafiqul Islam | Hasan, Moinul | Rosy, Tasmia Akter | Bari, Farida Yeasmin | Juyena, Nasrin Sultana
Monitoring vaginal electrical resistance, follicular waves, and hormonal profile during oestrous cycle in the transition period in Bangladeshi sheep Full text
2018
Talukder, Mohammad Rafiqul Islam | Hasan, Moinul | Rosy, Tasmia Akter | Bari, Farida Yeasmin | Juyena, Nasrin Sultana
Introduction: The ovarian follicular dynamics, vaginal electrical resistance (VER), progesterone (P4) and oestrogen (E2) profiles were investigated during the oestrous cycle in four indigenous ewes. Material and Methods: Daily VER values were recorded with a heat detector. The follicles were observed and measured by trans-rectal ultrasonography. Blood was collected daily for hormonal profiles. Results: A significant variation in VER values (P < 0.05) in oestrus by ewes and position in the sequence of cycles was observed. Trans-rectal ultrasonography of ovaries revealed the presence of 2–4 waves of follicular growth. Study of hormonal profiles by ELISA revealed a positive correlation between E2 concentration and development of follicles and a negative correlation between P4 concentration and their development. The concentrations of oestradiol increased in oestrus and then decreased to a basal level. Follicular growth was accompanied by a rise in the concentration of serum oestradiol. Inversely, when follicles received the stimulation for ovulation, concentration of progesterone started to fall, but after ovulation, it climbed back to its peak and remained at this state until next ovulatory follicle reached its maximum diameter. Conclusion: This study could help to set up a manipulative reproductive technique for improving genetic values in indigenous sheep.
Show more [+] Less [-]Monitoring vaginal electrical resistance, follicular waves, and hormonal profile during oestrous cycle in the transition period in Bangladeshi sheep Full text
2018
Talukder Mohammad Rafiqul Islam | Hasan Moinul | Rosy Tasmia Akter | Bari Farida Yeasmin | Juyena Nasrin Sultana
Introduction: The ovarian follicular dynamics, vaginal electrical resistance (VER), progesterone (P4) and oestrogen (E2) profiles were investigated during the oestrous cycle in four indigenous ewes.
Show more [+] Less [-]Heat Stress and Seasonal Dissipation of Circulating Zonulin Levels Among Calves in Aydın Region Full text
2022
Alıç Ural, Deniz
Zonulin, a well-recognized protein, is influencing the integrity of intercellular connections in the intestines. It has also been evidenced that heat stress (hS) might alter intestinal permeability. In the present retrospective field research the aim was to investigate the gastrointestinal permeability of calves exposed to hS (especially in summer) by determining serum zonulin levels and their relationship to seasonal dissipation among appearently healthy calves. As two different months represented 2 seasons, serum zonulin concentrations in January 2022 (at 20:00 pm 4°C and 08:00 am 10°C) and June 2022 (at 20:00 pm 19°C and 08:00 am 27°C) exhibited significant differences. Inter-group and intra-group comparison showed statistically significant differences (p=0.012) both in seasonal distribution and spatial distribution at different day/night times. When compared between the January and June groups, the mean zonulin levels (ng/mL) at 12 pm and 08:00 am in the January group were 28.04±12.49 vs. 11.55±8.45, respectively (p=0.012). On the other hand at June group the mean zonulin levels at 12 pm and 08.00 am were 58.54±19.16 vs 24.03±9.9, respectively (p=0.012). Obtained results should be cautiously subjected to interpretation, in which hS affect intestinal integrity and seasonal dissipation of circulating zonulin levels should be taken into consideration for intestinal health of calves.
Show more [+] Less [-]Antinociceptive efficacy and respiratory effects of dexmedetomidine in ball pythons (Python regius) Full text
2018
Bunke, Laura G. | Sladky, Kurt K. | Johnson, Stephen M.
OBJECTIVE To determine antinociceptive efficacy, behavioral patterns, and respiratory effects associated with dexmedetomidine administration in ball pythons (Python regius). ANIMALS 12 ball pythons. PROCEDURES Antinociception was assessed by applying an infrared heat stimulus to the cranioventral surface of snakes during 2 experiments. Thermal withdrawal latency was measured at 0, 2, and 24 hours after SC injections of dexmedetomidine (0.1 or 0.2 mg/kg) or saline (0.9% NaCl) solution and at 0 to 60 minutes after injection of dexmedetomidine (0.1 mg/kg) or saline solution. Behaviors were recorded at 0, 2, and 24 hours after administration of dexmedetomidine (0.1 mg/kg) or saline solution. Tongue flicking, head flinch to the approach of an observer's hand, movement, and righting reflex were scored. Respiratory frequency was measured by use of plethysmography to detect breathing-related movements after injection of dexmedetomidine (0.1 mg/kg) or saline solution. RESULTS Mean baseline withdrawal latency was 5 to 7 seconds; saline solution did not alter withdrawal latency. Dexmedetomidine increased withdrawal latency by 18 seconds (0.2 mg/kg) and 13 seconds (0.1 mg/kg) above baseline values at 2 hours. Increased withdrawal latency was detected within 15 minutes after dexmedetomidine administration. At 2 hours after injection, there were few differences in behavioral scores. Dexmedetomidine injection depressed respiratory frequency by 55% to 70%, compared with results for saline solution, but snakes continued to breathe without prolonged apnea. CONCLUSIONS AND CLINICAL RELEVANCE Dexmedetomidine increased noxious thermal withdrawal latency without causing excessive sedation. Therefore, dexmedetomidine may be a useful analgesic drug in ball pythons and other snake species.
Show more [+] Less [-]Effects of anesthetic induction with a benzodiazepine plus ketamine hydrochloride or propofol on hypothermia in dogs undergoing ovariohysterectomy Full text
2016
Bornkamp, Jennifer L. | Robertson, Sheilah | Isaza, Natalie M. | Erith | Digangi, Brian A. | Pablo, Luisito
OBJECTIVE To assess the effect of anesthetic induction with a benzodiazepine plus ketamine or propofol on hypothermia in dogs undergoing ovariohysterectomy without heat support. ANIMALS 23 adult sexually intact female dogs undergoing ovariohysterectomy. PROCEDURES Baseline rectal temperature, heart rate, and respiratory rate were recorded prior to premedication with buprenorphine (0.02 mg/kg, IM) and acepromazine (0.05 mg/kg, IM). Anesthesia was induced with midazolam or diazepam (0.25 mg/kg, IV) plus ketamine (5 mg/kg, IV; n = 11) or propofol (4 mg/kg, IV; 12) and maintained with isoflurane in oxygen. Rectal temperature was measured at hospital intake, prior to premedication, immediately after anesthetic induction, and every 5 minutes after anesthetic induction. Esophageal temperature was measured every 5 minutes during anesthesia, beginning 30 minutes after anesthetic induction. After anesthesia, dogs were covered with a warm-air blanket and rectal temperature was measured every 10 minutes until normothermia (37°C) was achieved. RESULTS Dogs in both treatment groups had lower rectal temperatures within 5 minutes after anesthetic induction and throughout anesthesia. Compared with dogs that received a benzodiazepine plus ketamine, dogs that received a benzodiazepine plus propofol had significantly lower rectal temperatures and the interval from discontinuation of anesthesia to achievement of normothermia was significantly longer. CONCLUSIONS AND CLINICAL RELEVANCE Dogs in which anesthesia was induced with a benzodiazepine plus propofol or ketamine became hypothermic; the extent of hypothermia was more profound for the propofol combination. Dogs should be provided with adequate heat support after induction of anesthesia, particularly when a propofol-benzodiazepine combination is administered.
Show more [+] Less [-]Assessments of thermal antinociceptive effects of butorphanol and human observer effect on quantitative evaluation of analgesia in green iguanas (Iguana iguana) Full text
2012
Fleming, Gregory J. | Robertson, Sheilah A.
Objective: To determine whether butorphanol induces thermal antinociception in green iguanas (Iguana iguana) and assess the human observer effect on quantitative evaluation of butorphanol-induced analgesia. Animals: 6 juvenile green iguanas. Procedures: Skin temperature was recorded, and then a direct increasing heat stimulus was applied to the lateral aspect of the tail base of each iguana. Temperature of the stimulus at which the iguana responded (thermal threshold) was measured before and for 8 hours after IM injection of either butorphanol tartrate (1.0 mg/kg) or an equal volume of saline (0.9% NaCl) solution. Six experiments (butorphanol [n = 3] and saline solution [3]) were conducted with the observer in the iguanas' field of vision, and 11 experiments (butorphanol [n = 5] and saline solution [6]) were conducted with the observer hidden from their view. The interval between treatments or tests was ≥ 1 month. Results: Temperature difference between thermal threshold and skin temperature when iguanas were administered saline solution did not differ from temperature difference when iguanas were administered butorphanol regardless of whether the observer was or was not visible. Temperature difference between thermal threshold and skin temperature was significantly lower when iguanas were tested without the observer in visual range, compared with the findings obtained when iguanas were tested with an observer in view, at multiple times after either treatment. Conclusions and Clinical Relevance: Intramuscular administration of 1.0 mg of butorphanol/kg did not induce thermal antinociception in juvenile green iguanas. The visible presence of an observer appeared to influence the results of noxious stimulus testing in this reptile species.
Show more [+] Less [-]Accuracy of isoflurane, halothane, and sevoflurane vaporizers during high oxygen flow and at maximum vaporizer dial setting Full text
2011
Ambrisko, Tamas D. | Klide, Alan M.
Objective-To assess the accuracy of isoflurane, halothane, and sevoflurane vaporizers during high oxygen flow and at maximum dial settings at room temperature and to test sevoflurane vaporizers similarly during heating and at low-fill states. Sample-5 isoflurane, 5 halothane, and 5 sevoflurane vaporizers. Procedures-Vaporizers were tested at an oxygen flow of 10 L/min and maximum dial settings for 15 minutes under various conditions. All 3 vaporizer types were filled and tested at room temperature (21 degrees to 23 degrees C). Filled sevoflurane vaporizers were wrapped with circulating hot water (42 degrees C) blankets for 2 hours and tested similarly, and near-empty sevoflurane vaporizers were tested similarly at room temperature. During each 15-minute test period, anesthetic agent concentration was measured at the common gas outlet with a portable refractometer and temperature of the vaporizer wall was measured with a thermistor. Results-For each vaporizer type, anesthetic agent concentrations and vaporizer wall temperatures decreased during the 15-minute test period. Accuracy of isoflurane and halothane vaporizers remained within the recommended 20% (plus or minus) deviation from dial settings. Heated and room-temperature sevoflurane vaporizers were accurate to within 23% and 11.7% (plus or minus) of dial settings, respectively. Sevoflurane vaporizers at low-fill states performed similarly to vaporizers at full-fill states. Conclusions and Clinical Relevance-Under these study conditions, the isoflurane and halothane vaporizer models tested were accurate but the sevoflurane vaporizers were not. Sevoflurane vaporizer accuracy was not affected by fill state but may be improved with vaporizer heating; measurements of inspired anesthetic agent concentrations should be obtained during the use of heated vaporizers.
Show more [+] Less [-]Cutaneous analgesia, hemodynamic and respiratory effects, and β-endorphin concentration in spinal fluid and plasma of horses after acupuncture and electroacupuncture Full text
2002
Skarda, Roman, T. | Tejwani, Gopi A. | Muir, William W III
Objective-To determine cutaneous analgesia, hemodynamic and respiratory effects, and β-endorphin concentration in spinal fluid and plasma of horses after acupuncture and electroacupuncture (EA). Animals-8 healthy 10- to 20-year-old mares that weighed between 470 and 600 kg. Procedure-Each horse received 2 hours of acupuncture and 2 hours of PAES at acupoints Bladder 18, 23, 25, and 28 on both sides of the vertebral column as well as sham needle placement (control treatment). Each treatment was administered in a random order. At least 7 days elapsed between treatments. Nociceptive cutaneous pain threshold was measured by use of skin twitch reflex latency (STRL) and avoidance to radiant heat (≤ 50°C) in the lumbar area. Skin temperature, cardiovascular and respiratory variables, and β-endorphin concentration in spinal fluid (CSF-EN) and plasma (plasma-EN) were measured. Results-Acupuncture and EA significantly increased STRL and skin temperature. The CSF-EN was significantly increased from baseline values 30 to 120 minutes after onset of EA, but it did not change after acupuncture and control treatments. Heart and respiratory rates, rectal temperature, arterial blood pressure, Hct, total solids and bicarbonate concentrations, base excess, plasma-EN, and results of blood gas analyses were not significantly different from baseline values after acupuncture, EA, and control treatments. Conclusion and Clinical Relevance-Administration of EA was more effective than acupuncture for activating the spinal cord to release beta-endorphins into the CSF of horses. Acupuncture and PAES provided cutaneous analgesia in horses without adverse cardiovascular and respiratory effects.
Show more [+] Less [-]