Evaluation of four drugs for inhibition of paracentesis-induced blood-aqueous humor barrier breakdown in cats
2011
Objective-To compare inhibitory effects of topically applied 1% prednisolone acetate suspension, 0.03% flurbiprofen solution, 0.1% dexamethasone suspension, and 0.1% diclofenac solution on paracentesis-induced blood-aqueous barrier breakdown in cats. Animals-9 healthy cats. Procedures-Paracentesis of the anterior chamber was performed in both eyes of each cat. One eye of each cat was treated with a topically administered anti-inflammatory medication (1% prednisolone [n = 7 cats], 0.03% flurbiprofen [7], 0.1% dexamethasone [9], or 0.1% diclofenac [8]) immediately following paracentesis and at 6, 10, and 24 hours after paracentesis. The contralateral untreated eye served as the control eye. Each cat had a 6-day washout period between experimental drugs. Breakdown of the blood-aqueous barrier was quantified by use of laser flaremetry. Results-Topical administration of 1% prednisolone significantly reduced aqueous humor flare at 4, 8, and 26 hours after paracentesis. Topical administration of 0.1% diclofenac significantly reduced aqueous humor flare at 8 and 26 hours after paracentesis. Topical administration of 0.1% dexamethasone and 0.03% flurbiprofen did not significantly decrease flare at any time point. There were significant differences in intraocular pressures between NSAID-treated eyes and untreated contralateral eyes. Conclusions and Clinical Relevance-Topical administration of 1% prednisolone and 0.1% diclofenac significantly reduced intraocular inflammation in cats with paracentesis-induced uveitis. Topical administration of 1% prednisolone or 0.1% diclofenac may be appropriate choices when treating cats with anterior uveitis. Topical administration of diclofenac and flurbiprofen should be used with caution in cats with a history of ocular hypertension.
Show more [+] Less [-]Evaluation of oscillometric and vascular access port arterial blood pressure measurement techniques versus implanted telemetry in anesthetized cats
2011
Zwijnenberg, Raphael J. | Rio, Carlos L del | Cobb, Rami M. | Ueyama, Yukie | Muir, William W.
Objective—To compare the use of a semi-invasive vascular access port (VAP) device or noninvasive oscillometry versus invasive telemetry for blood pressure measurements in cats. Animals—6 healthy cats. Procedures—30 days before the study, all cats received an implanted telemeter and a VAP device. During normotension and experimentally induced hypertension, blood pressure was measured with the implanted devices and with noninvasive oscillometry at 4 time points. Results—Compared with invasive telemetry, VAP had a correlation coefficient from 0.8487 to 0.9972, and noninvasive oscillometry had a correlation coefficient from 0.7478 to 0.9689. Conclusions and Clinical Relevance—Use of the VAP device and noninvasive oscillometry had a high degree of correlation with invasive telemetry as the gold standard for blood pressure measurement. Use of a VAP device resulted in a slightly higher degree of correlation, compared with noninvasive oscillometry.
Show more [+] Less [-]