Time required to achieve maximum amikacin concentration in the synovial fluid of the tarsocrural joint following administration of the drug by intravenous regional limb perfusion in horses
2021
OBJECTIVE To determine the median time to maximum concentration (tmax) of amikacin in the synovial fluid of the tarsocrural joint following IV regional limb perfusion (IVRLP) of the drug in a saphenous vein of horses. ANIMALS 7 healthy adult horses. PROCEDURES With each horse sedated and restrained in a standing position, a 10-cm-wide Esmarch tourniquet was applied to a randomly selected hind limb 10 cm proximal to the point of the tarsus. Amikacin sulfate (2 g diluted with saline [0.9% NaCl] solution to a volume of 60 mL) was instilled in the saphenous vein over 3 minutes with a peristaltic pump. Tarsocrural synovial fluid samples were collected at 5, 10, 15, 20, 25, and 30 minutes after completion of IVRLP. The tourniquet was removed after collection of the last sample. Amikacin concentration was quantified by a fluorescence polarization immunoassay. Median maximum amikacin concentration and tmax were determined. RESULTS 1 horse was excluded from analysis because an insufficient volume of synovial fluid for evaluation was obtained at multiple times. The median maximum synovial fluid amikacin concentration was 450.5 μg/mL (range, 304.7 to 930.7 μg/mL), and median tmax was 25 minutes (range, 20 to 30 minutes). All horses had synovial fluid amikacin concentrations ≥ 160 μg/mL (therapeutic concentration for common equine pathogens) at 20 minutes after IVRLP. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that, in healthy horses, maintaining the tourniquet for 20 minutes after IVRLP of amikacin in a saphenous vein was sufficient to achieve therapeutic concentrations of amikacin in the tarsocrural joint.
Show more [+] Less [-]Serum insulin-like growth factor-1 measurements in dogs: Performance characteristics of an automated assay and study of some sources of variation
2011
Tvarijonaviciute, Asta | Tecles, Fernando | Carillo, José M. | Rubio, Mónica | Ceron, José J.
The aim of this study was to evaluate the performance characteristics of an automated immunoassay for canine insulin-like growth factor 1 (IGF-1) measurement and to investigate the possible effects of some sources of variation, such as diurnal variations, feeding/fasting cycles, and glucocorticoid administration, in dogs. The immunoassay evaluated had an adequate analytical performance with intra- and inter-assay coefficients of variation (CVs) lower than 10%, linear regression equations with correlation coefficients of 0.9993 and 0.9988 after serial dilutions, and a limit of quantification of 7.1 ng/mL that was even lower than that reported by the manufacturer. The assay was significantly affected by hemolysis and lipemia producing a significant decrease in IGF-1 concentrations, but not by bilirubinemia. Serum IGF-1 concentrations did not show significant diurnal changes in fed or fasted dogs and were not affected by glucocorticoid administration.
Show more [+] Less [-]Comparison of two tourniquets and determination of amikacin sulfate concentrations after metacarpophalangeal joint lavage performed simultaneously with intravenous regional limb perfusion in horses
2011
Alkabes, Stephane B. | Adams, Stephen B. | Moore, George E. | Alkabes, Kira C.
Objective--To determine whether joint lavage performed simultaneously with IV regional limb perfusion (IVRLP) reduces the effectiveness of IVRLP and to compare 2 types of tourniquets used for this procedure in horses. Animal--11 adult horses. Procedures--2 groups of 6 horses were tested by use of a pneumatic or an Esmarch tourniquet (1 horse was tested twice [once in each group]). Standing IVRLP with amikacin (500 mg) was performed for 30 minutes. Simultaneously, the metacarpophalangeal joint was lavaged with 2 L of lactated Ringer's solution and the egress fluids were collected. Samples of the distal interphalangeal joint synovial fluid and blood from the digital and jugular veins were collected at set time intervals. Amikacin concentrations in all fluids were determined via fluorescence polarization immunoassay. Results--Less amikacin was measured in the systemic circulation with the Esmarch tourniquet than with the pneumatic tourniquet. Amikacin concentrations in the synovial fluid from the distal interphalangeal joints of the Esmarch tourniquet group ranged from 45.1 to 1,968 μg/mL and in the pneumatic tourniquet group ranged from 1.7 to 92.3 μg/mL after 30 minutes of IVRLP. Total loss of amikacin in the egress fluids from the joint lavage ranged from < 1.36 to 7.72 mg for the Esmarch tourniquet group and from < 1.20 to 1.75 mg for the pneumatic tourniquet group. Conclusions and Clinical Relevance--On standing horses, IVRLP performed simultaneously with joint lavage resulted in negligible loss of amikacin in the egress lavage fluids. The Esmarch tourniquet was more effective in preventing loss of amikacin from the distal portion of the limb, easier to use, and less expensive than the pneumatic tourniquet.
Show more [+] Less [-]Effects of anti-arthritis preparations on gene expression and enzyme activity of cyclooxygenase-2 in cultured equine chondrocytes
2002
Tung, Jayne T. | Venta, Patrick J. | Eberhart, Susan W. | Yuzbasiyan-Gurkan, Vilma | Alexander, Lee | Caron, John P.
Objective-To determine the effects of recombinant equine interleukin -1beta (reIL-1beta) and 4 anti-inflammatory compounds on the expression and activity of cyclooxygenase (COX)-2 in cultured equine chondrocytes. Sample Population-Articular cartilage from 9 young adult horses. Procedure-Reverse transcriptase-polymerase chain reaction methods were used to amplify a portion of equine COX-2 to prepare a cDNA probe. Northern blot analysis was used to quantify the expression of COX-2 in first-passage cultures of equine articular chondrocytes propagated in media containing dexamethasone (DEX), phenylbutazone (PBZ), polysulfated glycosaminoglycan, and hyaluronan, each at concentrations of 10 and 100 micrograms/ml and each with or without reIL-1beta. A commercial immunoassay was used to determine prostaglandin E2 (PGE2) concentrations in conditioned medium of similarly treated cells to quantify COX-2 activity. Results-Addition of reIL-1beta increased the expression of COX-2 in a dose-dependent manner, which was paralleled by an increased concentration of PGE2 in culture medium. Concentration of PGE2 in spent medium from reIL-1beta-treated chondrocytes was significantly reduced by DEX and PBZ; however, only DEX significantly reduced gene expression of COX-2. Conclusions and Clinical Relevance-Prostaglandin E2 is considered to be an important mediator in the pathophysiologic processes of arthritis, and cultured chondrocytes respond to interleukin-1 with enhanced expression and activity of COX-2. Palliative relief in affected horses is probably attributable, in part, to inhibition of PGE2 synthesis; however, analysis of these data suggests that of the 4 compounds tested, only DEX affects pretranslational regulation of the COX-2 gene in cultured equine chondrocytes.
Show more [+] Less [-]Assessment of a commercially available point-of-care assay for the measurement of bovine cardiac troponin I concentration
2013
Fraser, Brandon C. | Anderson, David E. | White, Brad J. | Miesner, Matt D. | Wheeler, Carrie | Amrine, David | Lakritz, Jeff | Overbay, Tom
Objective-To assess a commercially available point-of-care assay for measurement of bovine cardiac troponin I (cTnI) concentration in blood and plasma samples. Sample-Prepared bovine plasma standard samples with known concentrations (0 to 1.0 ng/mL) of cTnI and blood and plasma samples obtained from 28 healthy 2.5-month-old Holstein calves. Procedures-Coefficients of variation were calculated for concentrations of cTnI in prepared standards determined with the point-of-care assay, and values were compared with the known concentrations. The cTnI concentrations in blood samples obtained from calves determined with the point-of-care assay were compared with cTnI concentrations in plasma samples obtained from those animals determined with a validated immunoassay. Results-The coefficients of variation of cTnI concentrations determined for prepared standards by use of the point-of-care assay were low (< 20%) for standards with cTnI concentrations ≥ 0.025 ng/mL. The blood cTnI concentrations determined with the point-of-care assay were not significantly different from the plasma cTnI concentrations determined with the validated immunoassay. Conclusions and Clinical Relevance-Results of this study indicated the point-of-care assay had high precision for determination of cTnI concentrations in most evaluated prepared bovine plasma standard samples. The point-of-care assay may be useful for determination of circulating concentrations of cTnI in cattle.
Show more [+] Less [-]Purification and partial characterization of canine pepsinogen A and B
2002
Suchodolski, Jan S. | Steiner, Jörg M. | Ruaux, Craig G. | Boari, Andrea | Williams, David A.
Objective-To purify and partially characterize various isoforms of canine pepsinogen (PG) from gastric mucosa. Sample Population-Stomachs obtained from 6 euthanatized dogs. Procedure-Mucosa was scraped from canine stomachs, and a crude mucosal extract was prepared and further purified by use of weak anion-exchange chromatography, hydroxyapatite chromatography, size exclusion chromatography, and strong anionexchange chromatography. Pepsinogens were characterized by estimation of molecular weights, estimation of their isoelectric points (IEPs), and N-terminal amino acid sequencing. Results-Two different groups of canine PG were identified after the final strong anion-exchange chromatography: PG A and PG B. Pepsinogens differed in their molecular weights and IEP. Pepsinogen B appeared to be a dimer with a molecular weight of approximately 34,100 and an IEP of 4.9. Pepsinogen A separated into several isoforms. Molecular weights for the various isoforms of PG A ranged from 34,200 to 42,100, and their IEPs ranged from 4.0 to < 3.0. The N-terminal amino acid sequence for the first 25 amino acid residues for PG A and B had good homology with the amino acid sequences for these proteins in other species. Conclusions and Clinical Relevance-Canine PG B and several isoforms of canine PG A have been purified. Availability of these PGs will facilitate development of immunoassays to measure PG in canine serum as a potential diagnostic marker for gastric disorders in dogs.
Show more [+] Less [-]Absorption of diazepam after its rectal administration in dogs
1995
Papich, M.G. | Alcorn, J.
A cross-over study was performed in 6 healthy mixed-breed dogs and 4 healthy Beagles. Diazepam was administered per rectum to Beagles (0.5 mg/kg of body weight) and mixed-breed dogs (2 mg/kg), and IV (0.5 mg/kg) to both groups of dogs. Each dog received the drug by both routes, with a 1-week washout period between dosages. After diazepam administration, blood samples were collected to measure plasma concentration of diazepam and its active metabolites, desmethyldiazepam and oxazepam, by use of reverse-phase high-performance liquid chromatography (HPLC). Systemic availability was assessed by comparing the area under the curve for diazepam metabolites for each route of administration. Mean (+/- SD) diazepam concentrations in plasma after rectal administration were low in comparison with those obtained after IV administration, with systemic availability of only 7.4 (+/- 5.9) and 2.7 (+/- 3.2)% for the high and low dose, respectively. However, diazepam was converted to its metabolites within minutes after administration. Accounting for the total concentration of benzodiazepines (diazepam plus desmethyldiazepam and oxazepam) in plasma, systemic availability was 79.9 (+/- 20.7) and 66.0 (+/- 23.8)% for the high and low dosage, respectively. After IV administration, diazepam concentration decreased, with a half-life of only 14 to 16 minutes, but desmethyldiazepam and oxazepam concentrations decreased more slowly, with a half-life of 2.2 to 2.8 hours and 3.5 to 5.1 hours, respectively. Each of the metabolites is reported to have anticonvulsant activity. After rectal administration of the high dose, mean total benzodiazepine concentration was above 1.0 micrograms/ml within 10 minutes and was maintained above this concentration for at least 6 hours. We conclude that diazepam is absorbed after rectal administration in dogs, and that the pharmacologic effects are probably caused by the active metabolites, not the parent drug. Samples also were analyzed by use of a nonspecific commercial benzodiazepine fluorescence polarization immunoassay (FPIA). Correlation between the FPLA and HPLC assay was strongest for diazeparn (R2 = 0.84), weak for desmethyldiazepam (R2 = 0.09), and nonexistent for oxazepam. We conclude from a comparison of assays that HPLC is preferred over the FPLA method for measuring benzodiazepines in dogs.
Show more [+] Less [-]Quantitation of canine plasma von Willebrand factor antigen using a commercial enzyme-linked immunosorbent assay
1991
Johnstone, I.B. | Crane, S.
The purpose of this study was to evaluate a commercial enzyme-linked immunosorbent assay (ELISA) for human von Willebrand factor antigen (vWF:Ag) with respect to its potential value in quantitating the protein in canine plasma. The assay was a sandwich technique using F(ab')2 fragments specific for von Willebrand factor (vWF) and a peroxidase conjugated rabbit anti-vWF second antibody, with a microplate as the support surface. Canine plasmas were assayed by ELISA, and by Laurell electroimmunoassay (EIA), our reference methodology. The ELISA had a within-day variation of 1.21-4.44% and a between-day variation of 0.85-4.88% depending on the level of vWF:AG. The sensitivity of the assay was less than 0.1% vWF:AG. The range of vWF:AG concentrations in plasmas from 24 clinically normal dogs compared favorably with the range for the same plasmas when assayed by EIA (ELISA = 60-152% of normal; EIA = 50-142% of normal). In 121 canine plasmas with vWF:AG concentrations (as assessed by EIA) ranging from undetectable levels (< 6% of normal) to 142% of normal, there was good correlation with measurements made by ELISA (correlation coefficient = 0.835). It was concluded that this commercial ELISA technique could be used to provide reliable, same-day measurements of canine plasma vWF:AG. Since it requires no special equipment other than a microplate reader and washer it is particularly suitable for laboratories lacking the electrophoretic expertise or equipment required for EIA.
Show more [+] Less [-]Detection of infectious hematopoietic necrosis virus in an invertebrate (Callibaetis sp)
1989
Shors, S.T. | Winston, V.
Infectious hematopoietic necrosis virus (IHNV) was detected in the common Mayfly (Callibaetis sp) by western immunoblot assay and was propagated in fish cells (CHSE-214) in culture. When propagated in cell culture, cytopathic effect characteristic of IHNV infection was observed. Antibody specific for IHNV was used to detect all of the major proteins of IHNV in the western immunoblot assay. When the crude lysate was subjected to electron microscopy, bullet-shaped particles (84 nm X 194 nm) characteristic of IHNV were observed. The data suggested that the Mayfly may be a factor in the dissemination of IHNV.
Show more [+] Less [-]