Muscle hemodynamics in hereditary myopathy of Labrador Retrievers
1988
Amann, J.F. | Laughlin, M.H. | Korthuis, R.J.
Morphologic lesions seen in six 8-month-old Labrador Retrievers with hereditary myopathy were predominantly small- and large-group atrophy of muscle cells of all fiber types. The dogs were intolerant of excerise and fatigued rapidly. An isolated gracilis muscle preparation was used to study the hemodynamic features of the microvasculature. Isogravimetric capillary pressure as well as arterial and venous pressures in the isolated gracilis muscle preparation obtained during maximal vasodilatation were within the range reported for healthy, mixed-breed dogs, as were precapillary, postcapillary, and total vascular resistances. Capillary filtration and osmotic reflection coefficients were not different from those reported in other studies on healthy dogs. All measurements and calculations were reported during reperfusion, subsequent to a 4-hour period of global ischemia. Postischemic vascular responses were similar to the pattern previously reported in healthy dogs. These studies did not support the hypothesis of a vascular defect as a cause of hereditary myopathy in Labrador Retrievers.
Show more [+] Less [-]Comparison of clinical judgment, Doppler ultrasound, and fluorescein fluorescence as methods for predicting intestinal viability in the pony
1988
Odoh, Bethrand Toochukwu | Gentile, D.G. | Richardson, D.W. | Fetrow, J.P. | Tulleners, E.P. | Orsini, J.A. | Cimprich, R.
Strangulation obstruction was induced in anesthetized ponies for periods of 2 and 3 hours by clamping 45-cm segments of jejunum and associated veins (venous strangulation obstruction) and arteries and veins (arterial and venous strangulation obstruction). Four segments were studied in each of 7 ponies allowed to survive 12 hours, 2 segments in a pony that was allowed to survive 1 hour, and 1 segment in each of 10 ponies allowed to survive 42 days after the strangulation periods ended. Fifteen minutes after the periods of strangulation obstruction ended, the viability of test segments was assessed by clinical judgment (40 segments), fluorescein fluorescence (40 segments), and Doppler ultrasound (32 segments). Because thetest segments were normal at necropsy in long-term survivors, all segments were designated as viable. The overall accuracy of the methods used to predict viability was 88% for Doppler ultrasound and 53% each for clinical judgment and fluorescein fluorescence (P less than 0.005). Failures in the last 2 techniques could be attributed to their tendency to score venous strangulation obstruction segments as nonviable (90% for each). Doppler ultrasound was 94% accurate in these segments.
Show more [+] Less [-]