Refine search
Results 1-7 of 7
Description of technique and lower reference limit for magnetic resonance imaging of hippocampal volumetry in dogs
2013
Milne, Marjorie E. | Anderson, Garry A. | Chow, Kathleen E. | O'Brien, Terrence J. | Moffat, Bradford A. | Long, Sam N.
Objective: To evaluate the use of high-resolution MRI for hippocampal volumetry in dogs and to define a lower reference limit for hippocampal formation (HF) volume. Animals: 20 dogs (with no history of seizures and no underlying structural brain disease) that underwent MRI of the brain. Procedures: The MRI protocol included a high-resolution T1-weighted 3-D ultrafast gradient-echo sequence aligned in a dorsal plane perpendicular to the long axis of the HF. Images obtained with MRI were retrospectively analyzed by 2 observers (A and B). Intraobserver and interobserver agreement were calculated with the Lin concordance correlation coefficient. Volume measurements of the HF were adjusted for intracranial volume, and a lower 95% reference limit for adjusted HF volume was calculated. Results: There was substantial intraobserver agreement (Lin concordance correlation coefficient, 0.97 [95% confidence interval {CI}, 0.94 to 0.99]) but poor interobserver agreement (Lin concordance correlation coefficient, 0.63 [95% CI, 0.37 to 0.79]). The lower 95% reference limit for adjusted HF volume was 0.56 cm3 (90% CI, 0.52 to 0.60 cm3) for the right HF and 0.55 cm3 (90% CI, 0.52 to 0.58 cm3) for the left HF. Conclusions and Clinical Relevance: HF volumes should be adjusted for intracranial volume to account for the large variation in canine skull size. The amount of time required to perform HF volumetry and low interobserver agreement may restrict this technique to research applications, such as the investigation of epileptic patients for hippocampal sclerosis or other cognitive disorders.
Show more [+] Less [-]Comparison of concentrations of γ-aminobutyric acid and glutamate in cerebrospinal fluid of dogs with idiopathic epilepsy with and without seizure-related magnetic resonance imaging hyperintense areas in the limbic system
2013
Creevy, Kate E. | Gagnepain, John F. | Platt, Simon R. | Edwards, Gaylen L. | Kent, Marc
Objective-To investigate differences in CSF concentrations of excitatory and inhibitory neurotransmitters in dogs with and without T2-weighted (T2W) MRI hyperintense areas in the limbic system. Sample-Archived CSF samples and stored brain MRI images of 5 healthy research dogs (group 1), 8 dogs with idiopathic epilepsy (IE) with no abnormal MRI findings (group 2), and 4 dogs with IE with hyperintense areas in the limbic system detected by means of T2W MRI (group 3). Procedures-Archived CSF samples and stored MRI images obtained from all dogs were evaluated. Dogs in groups 2 and 3 were matched on the basis of age and breed. High-performance liquid chromatography was used to evaluate glutamate and γ-aminobutyric acid (GABA) concentrations in CSF samples. Results-Glutamate concentrations were higher in CSF of both groups of dogs with IE than in healthy dogs. However, glutamate concentrations in CSF were not significantly higher in dogs with IE and with hyperintense areas than in dogs with IE but no abnormal MRI findings. Concentrations of GABA in CSF were higher in group 3 than in group 2 and in group 2 than in group 1. Conclusions and Clinical Relevance-No significant difference was evident between glutamate concentrations in CSF of dogs with IE and with and without hyperintense areas detected by means of T2W MRI. However, glutamate concentrations typically were higher in CSF of dogs with IE and MRI hyperintense areas. Future studies with larger sample sizes should be conducted to confirm this finding and to determine the clinical importance of high glutamate concentrations in CSF of dogs with IE.
Show more [+] Less [-]Evaluation of osteochondral sample collection guided by computed tomography and magnetic resonance imaging for early detection of osteoarthritis in centrodistal joints of young Icelandic horses
2013
Ley, Charles J. | Ekman, Stina | Dahlberg, Leif E. | Björnsdóttir, Sigríður | Hansson, Kerstin
Objective-To evaluate the use of CT and MRI for guidance of osteochondral sample collection for histologic detection of early osteoarthritic lesions in centrodistal (distal intertarsal) joints of horses. Sample -Right tarsal joints from the cadavers of 24 Icelandic horses aged 29 to 31 months. Procedures-CT and MRI were used to evaluate the extent of suspected osteoarthritic changes in centrodistal joints, which were graded with a semiquantitative system. The anatomic regions with the highest grade of change were identified, and osteochondral samples were obtained from these regions. Samples were also obtained from the same centrodistal joints at predetermined sites. Histologic examination of all samples was performed, with samples classified as negative or positive for osteoarthritis, and results were compared between sample collection methods. Results-Histologic examination revealed osteoarthritic lesions in 29% (7/24) of centrodistal joints with the predetermined method and in 63% (15/24) with the image-guided method. Significant associations were identified between histologic osteoarthritis detection and the summed image-guided sample collection site image grades, central osteophytes, articular cartilage thickness abnormalities, grade 2 articular mineralization front defects, and grade 2 marginal osteophytes. Conclusions and Clinical Relevance-CT and MRI aided the detection of focal changes suggestive of early-stage osteoarthritis in the centrodistal joints of equine cadavers and may be useful for detection of similar disease in live horses. The first morphological changes of centrodistal joint osteoarthritis were suspected to be in the articular cartilage and the articular mineralization front regions.
Show more [+] Less [-]Assessment of left ventricular volumes by use of one-, two-, and three-dimensional echocardiography versus magnetic resonance imaging in healthy dogs
2013
Meyer, Judith | Wefstaedt, Patrick | Dziallas, Peter | Beyerbach, Martin | Nolte, Ingo | Hungerbühler, Stephan O.
Objective-To quantify left ventricle (LV) volumes by use of 1-D, 2-D, and 3-D echocardiography versus MRI in dogs. Animals-10 healthy Beagles. Procedures-During anesthesia, each dog underwent an echocardiographic examination via the Teichholz method, performed on the basis of standard M-mode frames (1-D); the monoplane Simpson method of disk (via 2-D loops); real-time triplane echocardiography (RTTPE) with a 3-D probe; and real-time 3-D echocardiography with a 3-D probe. Afterward, cardiac MRI was performed. Values for the LV end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were compared between each echocardiographic method and the reference method (cardiac MRI). Results-No significant differences for EDV, ESV, and EF were detected between RTTPE and cardiac MRI. Excellent correlations (r = 0.97, 0.98, and 0.95 for EDV, ESV, and EF, respectively) were found between RTTPE and values for cardiac MRI. The other echocardiographic methods yielded values significantly different from cardiac MRI and results correlated less well with results of cardiac MRI for EDV, ESV, and EF. Use of the Teichholz method resulted in LV volume overestimation, whereas the Simpson method of disk and real-time 3-D echocardiography significantly underestimated LV volumes. Conclusions and Clinical Relevance-Use of RTTPE yielded excellent correlations and nonsignificant differences with cardiac MRI and is a suitable method for routine veterinary cardiac examination.
Show more [+] Less [-]Evaluation of cerebrospinal fluid lactate and plasma lactate concentrations in anesthetized dogs with and without intracranial disease
2013
Caines, Deanne | Sinclair, Melissa | Wood, Darren | Valverde, Alex | Dyson, Doris | Gaitero, Luis | Nykamp, Stephanie
The objectives of this study were to establish a reference interval for canine cerebrospinal fluid lactate (CSFL) and to compare CSFL and plasma lactate (PL) concentrations in anesthetized dogs with and without intracranial disease. Using a prospective study, canine blood and cerebrospinal fluid were collected for lactate analysis in 11 dogs with intracranial disease after undergoing magnetic resonance imaging (MRI) (Group ID-MRI), in 10 healthy dogs post-MRI (Group H-MRI), and in 39 healthy dogs after induction of anesthesia (Group H-Sx). Dogs were anesthetized for the procedures using different anesthetic protocols. Neurological scores (NS) and sedation scores (SS) were assessed pre-anesthesia in ID-MRI dogs. The CSFL reference interval [90% confidence interval (CI) for lower and upper limits] was 1.1 (1.0 to 1.2) to 2.0 (2.0 to 2.1) mmol/L. Mean ± SD CSFL concentrations were: ID-MRI, 2.1 ± 0.8; H-MRI, 1.6 ± 0.4; and H-Sx, 1.6 ± 0.2 mmol/L. There was a tendency for higher CSFL in dogs in the ID-MRI group than in those in the H-MRI or H-Sx groups (P = 0.12). There was agreement between CSFL and PL in ID-MRI dogs (P = 0.007), but not in dogs in H-MRI (P = 0.5) or H-Sx (P = 0.2). Of the ID-MRI dogs, those with worse NS had higher CSFL (r (2) = 0.44). The correlation between CSFL and PL in dogs with intracranial disease and between worse NS and higher CSFL warrants further investigation into the use of CSFL and PL for diagnostic and prognostic purposes.
Show more [+] Less [-]Relative metabolite concentrations and ratios determined by use of 3-T region-specific proton magnetic resonance spectroscopy of the brain of healthy Beagles
2013
Warrington, Christopher D. | Feeney, Daniel A. | Ober, Christopher P. | Jessen, Carl R. | Steward, Susan M. | Armién, Aníbal G. | Fletcher, Thomas F.
Objective—To determine relative concentrations of selected major brain tissue metabolites and their ratios and lobar variations by use of 3-T proton (hydrogen 1 [1H]) magnetic resonance spectroscopy (MRS) of the brain of healthy dogs. Animals—10 healthy Beagles. Procedures—3-T 1H MRS at echo times of 144 and 35 milliseconds was performed on 5 transverse slices and 1 sagittal slice of representative brain lobe regions. Intravoxel parenchyma was classified as white matter, gray matter, or mixed (gray and white) and analyzed for relative concentrations (in arbitrary units) of N-acetylaspartate (NAA), choline, and creatine (ie, height at position of peak on MRS graph) as well as their ratios (NAA-to-choline, NAA-to-creatine, and choline-to-creatine ratios). Peak heights for metabolites were compared between echo times. Peak heights for metabolites and their ratios were correlated and evaluated among matter types. Yield was calculated as interpretable voxels divided by available lobar voxels. Results—Reference ranges of the metabolite concentration ratios were determined at an echo time of 35 milliseconds (NAA-to-choline ratio, 1.055 to 2.224; NAA-to-creatine ratio, 1.103 to 2.161; choline-to-creatine ratio, 0.759 to 1.332) and 144 milliseconds (NAA-to-choline ratio, 0.687 to 1.788; NAA-to-creatine ratio, 0.984 to 2.044; choline-to-creatine ratio, 0.828 to 1.853). Metabolite concentration ratios were greater in white matter than in gray matter. Voxel yields ranged from 43% for the temporal lobe to 100% for the thalamus. Conclusions and Clinical Relevance—Metabolite concentrations and concentration ratios determined with 3-T 1H MRS were not identical to those in humans and were determined for clinical and research investigations of canine brain disease.
Show more [+] Less [-]Comparison of inversion recovery gradient echo with inversion recovery fast spin echo techniques for magnetic resonance imaging detection of navicular bone marrow lesions in horses
2013
Olive, Julien | Vila, Thibault | Serraud, Nicolas
Objective: To compare navicular bone marrow lesion (BML) conspicuity in the feet of horses as determined via 2 fat-suppressed MRI techniques, including standard short tau inversion recovery (STIR) and inversion recovery gradient echo (IRGE). Sample: Feet (n = 150) of horses with lameness referable to the distal portion of the digit. Procedures: STIR and IRGE sequences were obtained prospectively in all feet with a standing low-field equine MRI system. Presence of a BML was ascertained by identification of a characteristic combination of marrow alterations in T1-weighted, T2*-weighted, T2-weighted, and STIR images. Signal-to-noise and contrast-to-noise ratios were calculated on STIR and IRGE sequences in 56 feet with a navicular BML. Results: Signal-to-noise and contrast-to-noise ratios of both sequences correlated linearly (r = 0.87 and r = 0.92, respectively) but were significantly higher for STIR images (mean ± SD, 22.6 ± 12.7 and 12.4 ± 11.4, respectively), compared with IRGE images (13.7 ± 8.0 and 5.9 ± 7.2, respectively). Conclusions and Clinical Relevance: Results suggested that the IRGE sequence revealed BMLs significantly less conspicuously, compared with the standard STIR sequence. The 2 techniques cannot be used interchangeably, and IRGE is therefore not recommended as the sole fat-suppressed sequence for routine equine standing MRI protocols.
Show more [+] Less [-]