Refine search
Results 1-7 of 7
Turbinate perimeter ratio as an indicator of conchal atrophy for diagnosis of atrophic rhinitis in pigs
1989
Collins, M.T. | Backstrom, L.R. | Brim, T.A.
Transverse sections of snouts from 171 cross-bred (principally Yorkshire X American Landrace) pigs were evaluated for evidence of turbinate atrophy by use of conventional (atrophic rhinitis [AR] score) and morphometric methods. Of the 171 pigs, 35 were clinically normal (AR score, 0), 65 had mild AR (AR score, 1), 41 had moderate AR (AR score, 2), and 30 had severe AR (AR score, 3). Turbinate cross-sectional area (TA) and the ratio of TA to nostril cross-sectional area, called turbinate area ratio (TAR), had the lowest correlations (r = 0.24 to 0.55) with conventional AR score. Among clinically normal pigs, TA was greater in older pigs as expected, but the TAR values also were significantly (P less than 0.0001) different betwee n 15-week-old pigs (55 kg) and 22-week-old pigs (100 kg). Turbinate perimeter and turbinate perimeter ratio (TPR) were not influenced by pig age or source. The TPR values were closely correlated with subjective visual AR scores (r = 0.73), with AR scores derived by measuring the space between the ventral portion of the scroll and the floor of the nasal cavity (r = 0.72), and the actual size of this space in millimeters (r = 0.71). Mean TPR values for pigs assigned visual AR scores of 0, 1, 2, or 3 were 1.54, 1.25, 0.97, and 0.73, respectively. The 95% confidence intervals around these mean TRP values were discreet and did not overlap. Turbinate perimeter ratio, therefore, may be a more reliable morphometric measure of atrophic rhinitis and also provides parametric data suitable for quantitative analysis.
Show more [+] Less [-]Tracheal mucus transport rate in healthy horses
1989
Sweeney, C.R.
Tracheal mucus transport rates were measured over a 10-minute period in 20 healthy horses twice in 24 hours. The mean rate was 1.93 +/- 0.55 cm/min on day 1 and 1.99 +/- 0.49 cm/min 24 hours later. The mean difference between day 1 and day 2 (0.06 +/- 0.42 cm/min) was not significant (P = 0.55). The range on day 1 was 1.12 to 2.9 cm/min and 1.11 to 2.89 cm/min on day 2.
Show more [+] Less [-]Enzyme-linked immunosorbent assay for measurement of allergen-specific IgE antibodies in canine serum
1989
Kleinbeck, M.L. | Hites, M.J. | Loker, J.L. | Halliwell, R.E. | Lee, K.W.
A micro-ELISA, using horseradish peroxidase-conjugated anti-canine IgE and polystyrene microtitration wells for detection of allergen-specific IgE in canine serum, was developed. Specificity of anti-canine IgE was confirmed by reversed cutaneous anaphylaxis evaluations, gel-precipitation reactions, immunoelectrophoresis, immunoaffinity chromatography, and heat inactivation. Individual allergen blanks were used to account for variable nonspecific binding among various allergens, and results were normalized using 4 reference sera. Coefficients of variation for intra-assay and interassay variability ranged from 0.77 to 5.66% and 3.15 to 9.83%, respectively. Results observed with wells coated with mixtures of various allergen extracts yielded results approximately equal to results (average) of wells containing individual components. Agreement between ELISA and skin test results ranged from 43 to 64%, depending on allergen used.
Show more [+] Less [-]Influence of limb temperature on sensory nerve conduction velocity in horses
1989
Wheeler, S.J.
Sensory nerve conduction velocity was measured in the lateral palmar nerve of 8 horses. The limb temperature was manipulated by external means and monitored. Alterations in the nerve conduction velocity related to limb temperature variation were identified at both increased and decreased temperatures. These were quantified and a mean value of 2.15 +/- 0.2 m/s/degree Celsius was determined. The effect of altered limb temperature should be considered in nerve conduction velocity determinations.
Show more [+] Less [-]Acute response of urine pH following ammonium chloride administration to dogs
1989
Shaw, D.H.
To test the acidifying ability of the distal portion of the nephrons in healthy dogs, 0.2 g of NH4Cl/kg of body weight was given PO. Samples for venous blood gas analysis and urine pH were taken hourly for 6 hours. Systemic acidemia developed, as evidenced by statistically significant (P less than 0.05) decrease in blood pH 1 hour after NH4Cl administration. Four hours after administration, mean urine pH decreased to a low of 5.16 +/- 0.1 and was less than 5.5 3 hours after administration. Changes in urine pH 2 hours after administration were statistically significant (P less than 0.05). In human beings, NH4Cl loading is used to detect patients with distal renal tubular acidosis (defective hydrogen ion secretion by the distal nephrons) and normal acid/base values. Distal renal tubular acidosis is diagnosed if urine pH fails to decrease to less than 5.5 after NH4Cl administration. On the basis of findings of this study, a similar value would be valid for dogs.
Show more [+] Less [-]Comparison of bovine and human platelet deformability, using micropipette elastimetry
1989
Smith, C.M. II. | Burris, S.M. | Weiss, D.J. | White, J.G.
We evaluated the deformability of bovine platelets and contrasted the effects of pharmacologic and thermal perturbations on cytoskeletal structure of human and bovine platelets. Platelets were aspirated into micropipettes (0.7 to 0.8 micromoles in diameter) by stepwise increments in tension. The resulting lengths of the cell extensions were recorded. The cell extensions aspirated from bovine platelets were shorter than the extensions drawn from human platelets. Disassembly of the circumferential microtubule coil allowed human platelets to pass through the pipette, but the same treatments only slightly increased the deformability of bovine platelets. Alteration of the actin filament cytoskeleton caused increased mechanical fragility of human platelets. In contrast, even the combined use of microtubule and actin filament-disrupting agents only modestly increased the deformability of bovine platelets and did not cause premature fragmentation of the cells. Unusual cytoskeletal structure, absence of an open canalicular system, and disparity in granule size may all contribute to the variance in deformability between the platelets of the 2 species. Reduced cell deformability may impair bovine platelet surface interactions by diminishing the ease of cell spreading and formation of areas of contact between the platelet and other cell surfaces.
Show more [+] Less [-]Application of a Hall-effect transducer for measurement of tendon strains in horses
1989
Stephens, P.R. | Nunamaker, D.M. | Butterweck, D.M.
Custom-designed Hall-effect strain sensors (HES) were implanted surgically onto the superficial digital flexor tendons of the forelimbs of 4 adult Thoroughbreds. Strains were recorded at various gaits, using a portable amplifer and FM cassette recorder. Strain calculations used the original length (L) as the HES position with the forelimb in the relaxed neutral position during anesthesia. A characteristic deflection in the strain cycle recording was confirmed to correspond to initial hoof contact with the ground (heel strike) by simultaneous recording of weight bearing via a footswitch. Heel strike was used as the reference point to determine the magnitude of strain change during weight bearing and nonweight bearing under various conditions. The weight-bearing strains (heel strike to maximal strain) recorded in 2 horses (with a rider) were 3.1% and 7.6% at the walk, 6.5% and 10.1% at the trot, and 11.5% and 16.6% at the gallop. Strain rate during tendon loading at the gallop was approximately 200%/s. The magnitude of strain change during nonweight bearing (minimal strain to heel strike) was smaller than during weight bearing, but also increased with faster gaits. In 3 horses led at the walk and trot, modest increases in hoof angle (baseline, 52%) resulted in small increases in the magnitude of strain change during weight bearing at the trot, but the magnitude of strain change at the walk was not affected. Results of the study indicated that the HES can be successfully adapted to provide continuous strain measurement without subjective signs of discomfort or lameness in horses during or after instrumentation.
Show more [+] Less [-]