Refine search
Results 1-2 of 2
In vitro evaluation of the knot-holding capacity and security, weight, and volume of forwarder knots tied with size-3 polyglactin 910 suture exposed to air, balanced electrolyte solution, or equine abdominal fat
2019
McGlinchey, Leah | Munsterman, Amelia S. | Coleridge, Matthew O. D. | Rosanowski, Sarah M. | Farag, Ramsis | Hanson, R Reid
OBJECTIVE To evaluate the effect of exposure to a balanced electrolyte solution (BES), or equine abdominal fat on the knot-holding capacity (KHC), relative knot security (RKS), weight, and volume of forwarder knots versus surgeon's knots. SAMPLE 315 knots tied and tested in vitro. PROCEDURES United States Pharmacopeia size-3 polyglactin 910 suture exposed to air (dry [control]), equine abdominal fat (fat-exposed), or BES (BES-exposed) was used to tie forwarder knots with 2, 3, and 4 throws and surgeon's knots with 5, 6, 7, and 8 throws. A universal materials testing machine was used to test the tensile strength of suture and knots to failure, and the KHC, RKS, weight, and volume of knots were determined. RESULTS Forwarder knots had significantly higher KHC and RKS and lower volume, compared with surgeons’ knots. Forwarder knots tied with fat-exposed suture had greater weight, but not volume, than did forwarder knots tied with dry or BES-exposed suture with the same number of throws. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that forwarder knots were superior to surgeon's knots when configured as start knots intended for continuous lines of suture. Exposure to media did not negatively affect mechanical or physical properties of forwarder knots and may improve specific biomechanical functions, including KHC and RKS.
Show more [+] Less [-]Quality assessment of fluconazole capsules and oral suspensions compounded by pharmacies located in the United States
2017
Laporte, Carnie M. | Cruz-Espindola, Crisanta | Thungrat, Kamoltip | Schick, Anthea E. | Lewis, Thomas P II | Boothe, Dawn M.
OBJECTIVE To evaluate pharmaceutical characteristics (strength or concentration, accuracy, and precision), physical properties, and bacterial contamination of fluconazole compounded products. SAMPLE Fluconazole compounded products (30- and 240-mg capsules; 30- and 100-mg/mL oral suspensions) from 4 US veterinary compounding pharmacies. PROCEDURES Fluconazole compounded products were ordered 3 times from each of 4 pharmacies at 7- or 10-day intervals. Generic fluconazole products (50- and 200-mg tablets; 10- and 40-mg/mL oral suspensions) served as references. Compounded products were evaluated at the time of receipt; suspensions also were evaluated 3 months later and at beyond-use dates. Evaluations included assessments of strength (concentration), accuracy, precision, physical properties, and bacterial contamination. Acceptable accuracy was defined as within ± 10% of the labeled strength (concentration) and acceptable precision as within ± 10%. Fluconazole was quantified by use of high-performance liquid chromatography. RESULTS Physical characteristics of compounded products differed among pharmacies. Aerobic bacterial cultures yielded negative results. Capsules (30 and 240 mg) had acceptable accuracy (median, 96.3%; range, 87.3% to 135.2%) and precision (mean ± SD, 7.4 ± 6.0%). Suspensions (30 and 100 mg/mL) had poor accuracy (median, 73.8%; range, 53.9% to 95.2%) and precision (mean ± SD, 15.0 ± 6.9%). Accuracy and precision were significantly better for capsules than for suspensions. CONCLUSIONS AND CLINICAL RELEVANCE Fluconazole compounded products, particularly suspensions, differed in pharmaceutical and physical qualities. Studies to evaluate the impact of inconsistent quality on bioavailability or clinical efficacy of compounded fluconazole products are indicated, and each study should include data on the quality of the compounded product evaluated.
Show more [+] Less [-]