Accuracy and repeatability of long-bone replicas of small animals fabricated by use of low-end and high-end commercial three-dimensional printers
2017
Cone, Jamie A. | Martin, Thomas M. | Marcellin-Little, Denis J. | Harrysson, Ola L. A. | Griffith, Emily H.
OBJECTIVE To assess the repeatability and accuracy of polymer replicas of small, medium, and large long bones of small animals fabricated by use of 2 low-end and 2 high-end 3-D printers. SAMPLE Polymer replicas of a cat femur, dog radius, and dog tibia were fabricated in triplicate by use of each of four 3-D printing methods. PROCEDURES 3-D renderings of the 3 bones reconstructed from CT images were prepared, and length, width of the proximal aspect, and width of the distal aspect of each CT image were measured in triplicate. Polymer replicas were fabricated by use of a high-end system that relied on jetting of curable liquid photopolymer, a high-end system that relied on polymer extrusion, a triple-nozzle polymer extrusion low-end system, and a dual-nozzle polymer extrusion low-end system. Polymer replicas were scanned by use of a laser-based coordinate measurement machine. Length, width of the proximal aspect, and width of the distal aspect of the scans of replicas were measured and compared with measurements for the 3-D renderings. RESULTS 129 measurements were collected for 34 replicas (fabrication of 1 large long-bone replica was unsuccessful on each of the 2 low-end printers). Replicas were highly repeatable for all 3-D printers. The 3-D printers overestimated dimensions of large replicas by approximately 1%. CONCLUSIONS AND CLINICAL RELEVANCE Low-end and high-end 3-D printers fabricated CT-derived replicas of bones of small animals with high repeatability. Replicas were slightly larger than the original bones.
Show more [+] Less [-]A technique of needle redirection at a single craniolateral site for injection of three compartments of the equine stifle joint
2017
Herdrich, Meredith R. A. | Arrieta, Shelby E. | Nelson, Brad B. | Frisbie, David D. | Moorman, Valerie J.
OBJECTIVE To determine accuracy for a technique of needle redirection at a single craniolateral site for injection of 3 compartments of the equine stifle joint, describe the external needle position, and identify the location of the needle tip within each joint compartment. SAMPLE 24 equine cadaver stifle joints. PROCEDURES Stifle joints were placed in a customized stand. After the needle was placed, external needle position was measured and recorded. Each joint compartment (medial and lateral compartments of the femorotibial joint and the femoropatellar joint) was injected with a solution containing iodinated contrast medium, water, and dye. Radiography, assessment of intra-articular location of the needle tip, and gross dissection were performed to determine success of entering each joint compartment. Student t tests and an ANOVA were used to compare mean values. RESULTS Overall accuracy was 19 of 24 (79.1%), and accuracy for individual joint compartments was at least 21 of 24 (87.5%). Mean depth of needle insertion to access each compartment of the stifle joint was 5.71 cm. Mean angle of insertion (relative to the long axis of the tibia) was 82.1°, 80.3°, and 18.5° for the medial compartment of the femorotibial joint, lateral compartment of the femorotibial joint, and femoropatellar joint, respectively, and 28° medial, 7.3° lateral, and 1.3° lateral for the medial compartment of the femorotibial joint, lateral compartment of the femorotibial joint, and femoropatellar joint, respectively. CONCLUSIONS AND CLINICAL RELEVANCE Results supported that this was an accurate technique for successful injection of the 3 equine stifle joint compartments.
Show more [+] Less [-]Repeatability of gait pattern variables measured by use of extremity-mounted inertial measurement units in nonlame horses during trotting
2017
Cruz, Antonio M. | Maninchedda, Ugo E. | Burger, Dominik | Wanda, Sabine | Vidondo, Beatriz
OBJECTIVE To determine repeatability of gait variables measured by use of extremity-mounted inertial measurement units (IMUs) in nonlame horses during trotting under controlled conditions of treadmill exercise. ANIMALS 10 horses. PROCEDURES Six IMUs were strapped to the metacarpal, metatarsal, and distal tibial regions of each horse. Data were collected in a standardized manner (3 measurements/d on 3 d/wk over a 3-week period) while each horse was trotted on a treadmill. Every measurement consisted of a minimum of 20 strides from which a minimum of 10 strides was selected for analysis. Spatial and temporal variables were derived from the IMUs. Repeatability coefficients based on the within-subject SD were computed for each gait analysis variable at each week. RESULTS Most of the temporal and spatial variables had high repeatability (repeatability coefficients < 10), and the repeatability coefficients were consistent among the 3 weeks of data collection. Some spatial variables, specifically the symmetry variables (which were calculated from other variables), had somewhat higher repeatability coefficients (ie, lower repeatability) only in the last week. CONCLUSIONS AND CLINICAL RELEVANCE With the exceptions of some symmetry variables, which may reflect individual variations during movement, the extremity-mounted IMUs provided data with high repeatability for nonlame horses trotting under controlled conditions of treadmill exercise. Repeatability was achieved for each instrumented limb segment with regard to the spatial relationship between 2 adjacent segments (joint angles) and the temporal relationship among all segments (limb phasing). Extremity-mounted IMUs could have the potential to become a method for gait analysis in horses.
Show more [+] Less [-]Biomechanics of an orthosis-managed cranial cruciate ligament-deficient canine stifle joint predicted by use of a computer model
2017
Bertocci, Gina E. | Brown, Nathan P. | Mich, Patrice M.
OBJECTIVE To evaluate effects of an orthosis on biomechanics of a cranial cruciate ligament (CrCL)-deficient canine stifle joint by use of a 3-D quasistatic rigid-body pelvic limb computer model simulating the stance phase of gait and to investigate influences of orthosis hinge stiffness (durometer). SAMPLE A previously developed computer simulation model for a healthy 33-kg 5-year-old neutered Golden Retriever. PROCEDURES A custom stifle joint orthosis was implemented in the CrCL-deficient pelvic limb computer simulation model. Ligament loads, relative tibial translation, and relative tibial rotation in the orthosis-stabilized stifle joint (baseline scenario; high-durometer hinge]) were determined and compared with values for CrCL-intact and CrCL-deficient stifle joints. Sensitivity analysis was conducted to evaluate the influence of orthosis hinge stiffness on model outcome measures. RESULTS The orthosis decreased loads placed on the caudal cruciate and lateral collateral ligaments and increased load placed on the medial collateral ligament, compared with loads for the CrCL-intact stifle joint. Ligament loads were decreased in the orthosis-managed CrCL-deficient stifle joint, compared with loads for the CrCL-deficient stifle joint. Relative tibial translation and rotation decreased but were not eliminated after orthosis management. Increased orthosis hinge stiffness reduced tibial translation and rotation, whereas decreased hinge stiffness increased internal tibial rotation, compared with values for the baseline scenario. CONCLUSIONS AND CLINICAL RELEVANCE Stifle joint biomechanics were improved following orthosis implementation, compared with biomechanics of the CrCL-deficient stifle joint. Orthosis hinge stiffness influenced stifle joint biomechanics. An orthosis may be a viable option to stabilize a CrCL-deficient canine stifle joint.