Refine search
Results 81-90 of 420
Application of Double ligation in 3 Dogs with Patent Ductus Arteriosus
2006
Yoon, H.Y. (Konkuk University, Seoul, Republic of Korea) | Kim, J.Y. (Konkuk University, Seoul, Republic of Korea) | Han, H.J. (Konkuk University, Seoul, Republic of Korea) | Jang, H.Y. (Konkuk University, Seoul, Republic of Korea) | Lee, B.R. (Konkuk University, Seoul, Republic of Korea) | Namkung, H.S. (Konkuk University, Seoul, Republic of Korea) | Park, H.M. (Konkuk University, Seoul, Republic of Korea) | Jeong, S.W. (Konkuk University, Seoul, Republic of Korea), E-mail: swjeong@konkuk.ac.kr
Three dogs with suspected patent ductus arteriosus were referred to Veterinary Medical Teaching Hospital of College of Veterinary Medicine, Konkuk University because of cough, shortness of breath, exercise intolerance, and syncope. Continuous murmur and thrill were detected in physical examination. Left ventricular enlargement, cardiomegaly, bulged main pulmonary artery were found in radiography. Tall R wave, wide P wave, artial fibrillation, and turbulent flow were observed in electrocardiogram and echocardiogram.
Show more [+] Less [-]Endotoxin-neutralizing activity of polymyxin B in blood after IV administration in horses
2006
Morresey, P.R. | MacKay, R.J.
Objectives-To measure serum polymyxin B concentration after single and repeated IV infusions in horses. Animals-5 healthy horses. Procedures-In study 1, 1 mg (6,000 U) of polymyxin B/kg was given IV and blood samples were collected for 24 hours. In study 2, 1 mg of polymyxin B/kg was given IV every 8 hours for 5 treatments and blood samples were collected until 24 hours after the last dose. Polymyxin B concentration was measured as the ability to suppress nitrite production by murine macrophages stimulated with lipopolysaccharide and interferon-alpha. Urine was collected prior to the first drug infusion and 24 hours after the fifth drug infusion for determination of urinary gamma-glutamyl transferase (GGT)-to-creatinine ratios. Results-In study 1, mean +/- SEM maximal serum polymyxin B concentration was 2.93 +/- 0.38 microgram/mL. Polymyxin B was undetectable 18 hours after infusion. In study 2, maximal polymyxin B concentrations after the first and fifth doses were 2.98 +/- 0.81 microgram/mL and 1.91 +/- 0.50 microgram/mL, respectively. Mean trough concentration for all doses was 0.22 +/- 0.01 microgram/mL. A significant effect of repeated administration on peak and trough serum concentration was not detected. Urine GGT-to-creatinine ratios were not affected by polymyxin B administration. Conclusions and Clinical Relevance-Polymyxin B given as multiple infusions to healthy horses by use of this protocol did not accumulate in the vascular compartment and appeared safe. Results support repeated IV use of 1 mg of polymyxin B/kg at 8-hour intervals as treatment for endotoxemia.
Show more [+] Less [-]Time-dependent alterations in gene expression of interleukin-8 in the bronchial epithelium of horses with recurrent airway obstruction
2006
Ainsworth, D.M. | Wagner, B. | Franchini, M. | Grunig, G. | Erb, H.N. | Tan, J.Y.
Objective-To evaluate time-dependent alterations in gene expression of chemokines in bronchial epithelium of recurrent airway obstruction (RAO)-affected horses and whether alterations resulted from increases in gene expression of interleukin (IL)-17 in cells isolated from bronchoalveolar lavage fluid (BALF). Animals-8 RAO-susceptible horses and 9 control horses. Procedure-In 2 experiments, both groups of horses were evaluated after being maintained on pasture and after being stabled and fed dusty hay for 1, 14, 35, and 49 days (experiment 1) or 14 and 28 days (experiment 2). In experiment 1, gene expression of IL-8, chemokine (C-X-C motif) ligand 1 (CXCL1), granulocyte-macrophage colony-stimulating factor (GM-CSF), granulocyte colony-stimulating factor (G-CSF), and Toll-like receptor 4 (TLR4) in epithelium and IL-8, IL-17, and TLR4 in BALF cells was measured. In experiment 2, bronchial biopsy specimens were evaluated for IL-8 immunoreactivity. Results-In RAO-susceptible horses after 14 days of challenge exposure, there was a 3- and 10-fold increase in gene expression of IL-8 for epithelial and BALF cells and an increase in IL-8 immunoreactivity in epithelial cells. Challenge exposure failed to alter gene expression of CXCL1, GM-CSF, G-CSF, and TLR4 in epithelial cells of any horses at any time point. During challenge exposure, gene expression of BALF cell IL-17 was downregulated in control horses (day 1) and upregulated in RAO-affected horses (day 35). Conclusions and Clinical Relevance-Epithelial-derived IL-8 may promote airway neutrophilia, but the inciting stimulus is unlikely to be IL-17 because upregulation of this gene is subsequent to that of IL-8 in epithelial cells.
Show more [+] Less [-]Effect of medetomidine on respiration and minimum alveolar concentration in halothane- and isoflurane-anesthetized dogs
2006
Lerche, P. | Muir, W.W III
Objective-To evaluate the effect of medetomidine on minimum alveolar concentration (MAC), respiratory rate, tidal volume, minute volume (V(M)), and maximum inspiratory occlusion pressure (IOCP(max)) in halothane- and isoflurane-anesthetized dogs. Animals-6 healthy adult dogs (3 males and 3 females). Procedure-The MAC of both inhalants was determined before and 5, 30, and 60 minutes after administration of medetomidine (5 microgram/kg, IV). Dogs were subsequently anesthetized by administration of halothane or isoflurane and administered saline (0.9% NaCl) solution IV or medetomidine (5 microgram/kg, IV). Respiratory variables and IOCP(max) were measured at specific MAC values 15 minutes before and 5, 30, and 60 minutes after IV administration of medetomidine while dogs breathed 0% and 10% fractional inspired carbon dioxide (FICO2). Slopes of the lines for V(M)/FICO2 and IOCP(max)/FICO2 were then calculated. Results-Administration of medetomidine decreased MAC of both inhalants. Slope of V(M)/FICO2 increased in dogs anesthetized with halothane after administration of medetomidine, compared with corresponding values in dogs anesthetized with isoflurane. Administration of medetomidine with a simultaneous decrease in inhalant concentration significantly increased the slope for V(M)/FICO2, compared with values after administration of saline solution in dogs anesthetized with halothane but not isoflurane. Values for IOCP(max) did not differ significantly between groups. Conclusions and Clinical Relevance-Equipotent doses of halothane and isoflurane have differing effects on respiration that are most likely attributable to differences in drug effects on central respiratory centers. Relatively low doses of medetomidine decrease the MAC of halothane and isoflurane in dogs.
Show more [+] Less [-]Evaluation of delayed-image bone scintigraphy to assess bone formation after distraction osteogenesis in dogs
2006
Theyse, L.F. | Hazewinkel, H.A. | Terlou, M. | Pollak, Y.W. | Voorhout, G.
Objective-To quantitatively assess distraction-induced bone formation in a crural lengthening model in dogs by use of delayed-image bone scintigraphy. Animals-12 mature Labrador Retrievers. Procedure-Dogs were randomly allocated to 1 of 3 groups. A circular external skeletal fixation system was mounted on the right crus of each dog. Osteotomy of the distal portion of the tibia and fibula was performed in groups 1 and 2 and was followed by a lengthening procedure of 10 mm in the first group only. The third group served as sham-operated controls. Delayed-image bone scintigraphy with technetium-99m hydroxy methylene diphosphonate was performed 2, 4, and 6 weeks after surgery. Delayed-image-to-region-of-interest, delayed-image-to-crural, and delayed-image-to-femoral scintigraphic activity ratios were calculated. New bone formation was quantified by use of densitometric image analysis, and values for the scintigraphic ratios were compared. Results-In the distraction and osteotomy groups, delayed-image-to-region-of-interest and delayed-image-to-crural ratios increased significantly. Although densitometric image analysis revealed increased bone formation after distraction, the region-of-interest ratios and crural ratios were similar in both groups. All dogs had increased delayed-image-to-femoral ratios. Conclusions and Clinical Relevance-Delayed-image bone scintigraphy ratios were not effective at differentiating between the amounts of distraction-induced bone and osteotomy-induced bone. Metabolic bone activity in the adjacent femur was increased as a consequence of circular external skeletal fixator placement. Delayed-image bone scintigraphy was not adequately sensitive to quantitatively monitor bone formation but may be useful as an early predictor of bone healing.
Show more [+] Less [-]Evaluation of isoflurane and sevoflurane vaporizers over a wide range of oxygen flow rates
2006
Ambrisko, T.D. | Klide, A.M.
Objective-To examine the accuracy and precision of isoflurane and sevoflurane anesthetic vaporizers. Sample Population-5 identcal isoflurane and 5 identical sevoflurane vaporizers. Procedures-Oxygen flow rates from 0.02 to 10 L/min were used with different vaporizer dial settings. Agent concentrations were measured at the common gas outlet by use of a refractometer. Accuracy was defined as the difference between measured agent concentrations, and dial settings were expressed as a percentage of the applied dial settings. Precision was defined as SD of the measured agent concentrations for each combination of dial setting and flow. Results-Isoflurane values were generally greater than the dial settings. Accuracy of the isoflurane vaporizer was > 20% when 0.6% and 1% was dialed. Accuracy of the sevoflurane vaporizer was always within +/- 20% but decreased at 0.02 L/min flow and at combinations of high flow and high dial settings. Overall precision of the isoflurane vaporizer was better than that of the sevoflurane vaporizer. Conclusions and Clinical Relevance-A possible explanation for the inaccuracy of the isoflurane vaporizer may be that it was manufactured to be accurate with air but not oxygen, which must be accounted for when using the vaporizer with oxygen, especially with nonrebreathing systems. The sevoflurane vaporizer may not deliver accurate agent concentrations at high flow and high dial settings. Both vaporizers are suitable for clinical use with a wide range of oxygen flow rates if these precautions are properly addressed.
Show more [+] Less [-]Infection with Porcine reproductive and respiratory syndrome virus stimulates an early gamma interferon response in the serum of pigs
2006
Wesley, R.D. | Lager, K.M. | Kehrli, M.E. Jr
The early release of cytokines by cells involved in innate immunity is an important host response to intracellular pathogens. Gamma interferon (IFN-gamma) is an important cytokine produced during the early stages of an infection by macrophages, natural killer (NK) cells, and other cell types, and it is also a central cytokine mediator for the induction of cellular or Th1 immunity. To better understand innate and adaptive immune responses after infection with Porcine reproductive and respiratory syndrome virus (PRRSV), we investigated serum IFN-gamma concentrations and the duration of viremia. For 2 strains of atypical PRRSV, IFN-gamma was detectable in swine serum soon after infection and lasted for approximately 3 wk. Serum concentrations of IFN-gamma peaked at about 10 d after inoculation and returned to approximately baseline levels by day 22. However, individual pigs manifested short, sporadic increases in the serum concentration of IFN-gamma from 18 to 50 d after inoculation. Prior vaccination blocked the serum IFN-gamma response associated with homologous virus challenge and altered the kinetics of the response after heterologous challenge. Two other respiratory viruses of pigs, Porcine respiratory coronavirus and Swine influenza virus, do not appear to induce serum IFN-gamma. The early production of IFN-gamma in PRRSV-infected pigs might result from activation of NK cells, a response that is more characteristic of immune pathways stimulated by intracellular bacterial and protozoan infections.
Show more [+] Less [-]In vitro efficacy of a buffered chelating solution as an antimicrobial potentiator for antifungal drugs against fungal pathogens obtained from horses with mycotic keratitis
2006
Weinstein, W.L. | Moore, P.A. | Sánchez, S. | Dietrich, U.M. | Wooley, R.E. | Ritchie, B.W.
Objective-To determine whether a novel third-generation chelating agent (8mM disodium EDTA dehydrate and 20mM 2-amino-2-hydroxymethyl-1, 3-propanediol) would act as an antimicrobial potentiator to enhance in vitro activity of antifungal medications against fungal isolates obtained from horses with mycotic keratitis. Sample Population-Fungal isolates (3 Aspergillus isolates, 5 Fusarium isolates, 1 Penicillium isolate, 1 Cladosporium isolate, and 1 Curvularia isolate) obtained from horses with mycotic keratitis and 2 quality-control strains obtained from the American Type Culture Collection (ATCC; Candida albicans ATCC 90028 and Paecilomyces variotii ATCC 36257). Procedure-Minimum inhibitory concentrations (MICs) against fungal isolates for 4 antifungal drugs (miconazole, ketoconazole, itraconazole, and natamycin) were compared with MICs against fungal isolates for the combinations of each of the 4 antifungal drugs and the chelating agent. The Clinical and Laboratory Standards Institute microdilution assay method was performed by use of reference-grade antifungal powders against the fungal isolates and quality-control strains of fungi. Results-Values for the MIC at which the antifungal drugs decreased the growth of an organism by 50% (MIC50) and 90% (MIC90) were decreased for the control strains and ophthalmic fungal isolates by 50% to 100% when the drugs were used in combination with the chelating agent at a concentration of up to 540 microgram/mL. Conclusions and Clinical Relevance-The chelating agent increased in vitro activity of antifungal drugs against common fungal pathogens isolated from eyes of horses with mycotic keratitis.
Show more [+] Less [-]Effect of meloxicam and butorphanol on minimum alveolar concentration of isoflurane in rabbits
2006
Turner, P.V. | Kerr, C.L. | Healy, A.J. | Taylor, Wm
Objective-To determine the effects of meloxicam and butorphanol on minimum alveolar concentration of isoflurane (MAC(ISO)) in rabbits. Animals-10 healthy young adult female rabbits. Procedure-Rabbits were anesthetized with isoflurane on 3 occasions in a blinded, randomized complete block design to determine the MAC(ISO) associated with administration of meloxicam (0, 0.3, or 1.5 mg/kg, PO) and butorphanol (0.4 mg/kg, IV). The MAC(ISO) was determined by use of a paw clamp technique as the end-tidal concentration of isoflurane halfway between the values that allowed or inhibited purposeful movement. Rectal temperature, end-tidal CO2 concentration, heart rate, oxygen saturation, and arterial blood pressure were measured to evaluate cardiopulmonary function. Results-Mean +/- SE MAC(ISO) in saline (0.9% NaCl) solution-treated rabbits was 2.49 +/- 0.07% and was not significantly different from that associated with administration of meloxicam at 0.3 mg/kg (2.56 +/- 0.07%) or 1.5 mg/kg (2.66 +/- 0.07%). Butorphanol significantly reduced the MAC(ISO) to 2.30 +/- 0.07% when administered with saline solution alone, 2.27 +/- 0.07% when administered with 0.3 mg of meloxicam/kg, and 2.33 +/- 0.07% when administered with 1.5 mg of meloxicam/kg. The percentage reduction in MAC(ISO) was significantly greater for rabbits that received butorphanol and meloxicam at either dose, compared with butorphanol and saline solution. Conclusions and Clinical Relevance-Results indicated that meloxicam does not have a direct isoflurane-sparing effect and does not interfere with the anesthetic-sparing effect of butorphanol in rabbits.
Show more [+] Less [-]Comparison of B-mode and Doppler ultrasonographic findings with histologic features of benign and malignant superficial lymph nodes in dogs
2006
Nyman, H.T. | Lee, M.H. | McEvoy, F.J. | Nielsen, O.L. | Martinussen, T. | Kristensen, A.T.
Objective-To compare and correlate B-mode and color Doppler ultrasonographic characteristics with histopathologic findings of benign and malignant superficial lymph nodes in dogs. Study Population-50 superficial lymph nodes that were normal, abnormally large on physical examination, or represented regional lymph nodes draining an area of suspected primary malignancy in 30 dogs. Procedures-Before excision, lymph nodes were evaluated via B-mode and color Doppler ultrasonography to assess size, echogenicity, presence of a hilus, acoustic transmission, and vascular flow. Formalin-fixed, paraffin-embedded tissue sections of excised lymph nodes were stained with H&E and examined for the presence and extent of necrosis, fibrosis, fat, metastases, and tissue heterogeneity. To assess vascularity, the number and distribution of vessels stained by the Verhoeff van Gieson technique were recorded. Results-In superficial lymph nodes, a varied echogenicity corresponded to tissue heterogeneity. The ultrasonographic detection of a hilus was associated with the presence of fibrous tissue, fat, or both in the hilar region. Acoustic enhancement corresponded to presence of areas of intranodal necrosis. There was significant correlation between both the distribution and the number of vessels detected via ultrasonography and that detected by histopathology. The amount of flow estimated via ultrasonography was typically higher than that estimated via histologic examination. Conclusions and Clinical Relevance-Results indicated that histopathologic changes in canine lymph nodes have associated ultrasonographic changes and suggest that lymph node ultrasonography has an important role in the evaluation of lymph nodes in dogs in general and in dogs with neoplastic disease in particular.
Show more [+] Less [-]