Refine search
Results 1-10 of 13
Multidrug-resistant enteroaggregative Escherichia coli (EAEC) enters dormant state during heat treatment: A potential hazard in municipal sludge
2022
Zhang, Bingni | Fu, Yulong | Wang, Feiyu | Yang, Jiawen | Pan, Zhiyu | Huang, Meiling | Shen, Kewei | Shen, Chaofeng
Reuse of sewage sludge is a general trend and land application is an essential way to reuse sludge. The outbreak of coronavirus disease has raised concerns about human pathogens and their serious threat to public health. The risk of pathogenic bacterial contamination from land application of municipal sludge has not been well assessed. The purpose of this study was to investigate the presence of pathogenic bacteria in municipal sewage sludge and to examine the survival potential of certain multidrug-resistant enteroaggregative Escherichia coli (EAEC) strain isolated from sewage sludge during heat treatment. The sewage sludge produced in the two wastewater treatment plants contained pathogenic bacteria such as pathogenic E. coli, Shigella flexneri, and Citrobacter freundii. The environmental strain of EAEC isolated from the sludge was resistant to eight types of antibiotics. It could also enter the dormant state after 4.5 h of treatment at 55 °C and regrow at 37 °C, while maintaining its antibiotic resistance. Our results indicate that the dormancy of EAEC might be why it is heat-resistant and could not be killed completely during the sludge heat treatment process. Owing to the regrowth of the dormant pathogenic bacteria, it is risky to apply the sludge to land even if the sludge is heat-treated, and there is also a risk of spreading antibiotic resistance.
Show more [+] Less [-]Dispersal of potentially pathogenic bacteria by plastic debris in Guanabara Bay, RJ, Brazil
2019
Silva, Mariana Muniz | Maldonado, Gustavo Carvalho | Castro, Rebeca Oliveira | de Sá Felizardo, João | Cardoso, Renan Pereira | Anjos, Roberto Meigikos dos | Araújo, Fábio Vieira de
Analyses of thermotolerant coliform and heterotrophic bacteria as well as Escherichia coli and Vibrio species were carried out on plastic samples and in the surrounding waters of Guanabara Bay to evaluate plastic debris as vehicles of bacterial dispersal. Chemical characterizations of plastics were performed using Fourier transform infrared spectroscopy (FTIR). Plastic debris with high coliform contents were found, while their respective water samples had only low titers. No correlations were observed, however, between the amounts of bacteria and the chemical compositions of the plastic debris. Forty-four bacterial strains were PCR-confirmed as E. coli pathotypes, and 59 strains of Vibrio spp. (with 12 being identified as Vibrio cholerae [6], Vibrio vulnificus [5], and Vibrio mimicus [1]). These findings suggest these plastics can function as a substrate for bacterial biofilms (including pathogens). These debris, in turn, can be dispersed in aquatic environments not otherwise showing recent fecal bacterial contamination.
Show more [+] Less [-]Chemical and biological assessment of sediments and water of Khalid Khor, Sharjah, United Arab Emirates
2016
Samara, Fatin | Elsayed, Yehya | Soghomonian, Balik | Knuteson, Sandra L.
Water and sediments were collected on March 2013 and April 2014 from Khalid Khor creek area in United Arab Emirates to assess their quality parameters. The pH and alkalinity of the water samples were measured and their values were similar to those of shallow saltwater ecosystems. In addition, elemental analyses and organic compounds were done using Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) and Gas Chromatography—Mass Spectroscopy (GC–MS), respectively. The concentration of heavy and trace metals in the water samples were within the acceptable limits except for lead which showed high values, while the concentrations of metals in the sediment samples were relatively high and ranged from 6517 to 13,768mg/kg. GC–MS analysis showed the presence of polyaromatic heterocyclic (PAHs) compounds in sediments near the shipping area and in amounts classified as highly carcinogenic; however, no polychlorinated biphenyls (PCB) were identified. Moreover, fecal bacterial contamination in water was detected in concentrations that range between 300 and 10,140 organisms/100mL.
Show more [+] Less [-]Comparison of Enterococcus density estimates in marine beach and bay samples by real-time polymerase chain reaction, membrane filtration and defined substrate testing
2011
Ferretti, James A. | Tran, Hiep V. | Cosgrove, Elizabeth | Protonentis, John | Loftin, Virginia | Conklin, Carol S. | Grant, Robert N.
Currently, densities of Enterococcus in marine bathing beach samples are performed using conventional methods which require 24h to obtain results. Real-time PCR methods are available which can measure results in as little as 3h. The purpose of this study was to evaluate a more rapid test method for the determination of bacterial contamination in marine bathing beaches to better protect human health. The geometric mean of Enterococcus densities using Enterolert® defined substrate testing and membrane filtration ranged from 5.2 to 150MPN or CFU/100mL and corresponding qPCR results ranged from 6.6 to 1785CCE/100mL. The regression analysis of these results showed a positive correlation between qPCR and conventional tests with an overall correlation (r) of 0.71. qPCR was found to provide accurate and sensitive estimate of Enterococcus densities and has the potential to be used as a rapid test method for the quantification of Enterococcus in marine waters.
Show more [+] Less [-]Ribbed mussel in an urban waterway filters bacteria introduced by sewage
2020
Durand, Sarah E. | Niespor, Robert | Ador, Aldrin | Govinda, Nirmela | Candia, Marta | Torres, Katherine
The ribbed mussel has been demonstrated to tolerate high levels of urban pollution and inhabits intertidal regions of the New York City estuary. The ability of this bivalve to filter bacteria raises the question of whether it can remove from the water column the fecal bacteria introduced to urban waterways by septic system leakage or sewer overflow. The study here addresses the hypothesis that ribbed mussel filters bacteria introduced by combined sewer overflow (CSO) discharge. Mussels and water were collected from a highly polluted region of the NYC estuary in order to conduct two sets of five trials for filtration of coliform and coccoid fecal indicator bacteria, respectively, Escherichia coli and Enterococcus species. Mussels and water samples were collected in proximity to a major CSO outfall within 1–2 days of a rainfall event to ensure high baseline values of bacterial contamination for filtration trials. For any given Enterococcus or E. coli trial, equal volume water samples were serially distributed across aerated tanks either containing a mussel or not. Comparison of with-mussel versus no-mussel tank water contamination across pooled trials showed significant (P < 0.05) reduction in water exposed to mussel filtration for both, Enterococcus and E. coli trials. For Enterococcus trials, measures of turbidity (suspended particle density) were taken concurrently with measures of bacterial contamination. Regression of contamination against turbidity, with measures standardized across trials, yielded a significant positive association (n = 50, P < 0.0001) across all tank water with a mussel. Thus, contamination reduction was associated with particle removal by mussel filtration.
Show more [+] Less [-]Microbiological and physicochemical analysis of the coastal waters of southern Brazil
2012
Moresco, V. | Viancelli, A. | Nascimento, M.A. | Souza, D.S.M. | Ramos, A.P.D. | Garcia, L.A.T. | Simões, C.M.O. | Barardi, C.R.M.
The aim of this study was to assess the impact of sewage discharge on coastal waters by evaluating the influence of physicochemical parameters on the presence of enteric microorganisms in seawater samples collected from 11 beaches in Florianopolis, Santa Catarina, Brazil, over a one-year period (August 2009 to July 2010). Samples were assessed for the presence of human adenoviruses (HAdV), polyomavirus (JCPyV), hepatitis A virus (HAV), and noroviruses (HuNoV GI and GII). Escherichia coli and physicochemical parameters (salinity, temperature, pH and dissolved oxygen) were also evaluated. From the 132 samples analyzed, 55% were positive for HAdV, 51.5% for HAV, 7.5% for HuNoV GI, 4.5% for HuNoV GII, and 3% for JCPyV. E. coli levels ranged from 8 to 1325CFU/100mL at all sites. The overall results highlight the problem of sewage discharge into coastal waters and confirm that there is no correlation between viral presence and bacterial contamination.
Show more [+] Less [-]Electrospun nanofibers of polyvinylidene fluoride incorporated with titanium nanotubes for purifying air with bacterial contamination
2021
Victor, Felix Swamidoss | Kugarajah, Vaidhegi | Bangaru, Mohan | Ranjan, Shivendu | Dharmalingam, Sangeetha
Polyvinylidene fluoride (PVDF) blended with varying concentrations of titanium nanotubes (TNT) was electrospun to result in a nanocomposite filter media. Sandwich structures were obtained by depositing the electrospun fibers between polypropylene (PP) nonwoven sheets. The synthesized tubular TNT was confirmed for its morphology through a transmission electron microscope (TEM). The prepared filter media was analyzed through a scanning electron microscope (SEM), X-ray diffraction (XRD), Fourier infrared spectroscopy (FTIR), and thermogravimetric analysis (TGA). The effectiveness of the filter media was evaluated through the zone of inhibition and antibacterial activity against E. coli and S. aureus. The Box-Behnken design is experimented with three-level variables, namely areal density of substrate (GSM), electrospinning time (hours), and concentration of TNT (wt%) for investigating the bacterial filtration efficiency through an Andersen sampler. Among other statistical tests (STATs), PVDF + 15 wt% TNT has a bacterial filtration efficiency of 99.88% providing greater potentials upon application for clean air management. It can be noted that the future application of this formulation could be efficient filtration of other microbes and could be used in facemasks to industrial-scale air filters. Graphical abstract
Show more [+] Less [-]Effect of Land Cover Changes on the Sediment and Water Quality Characteristics of Brays Bayou Watershed
2017
Bhandari, Sharmila | Maruthi Sridhar, B.B. | Wilson, BobbyL.
Rapid increase in impervious surfaces due to urbanization often intensifies the frequency of flooding which in turn increases runoff of environmental pollutants. The Brays Bayou watershed (BBW) is a heavily urbanized and densely populated watershed located mostly in Harris County, TX. The objectives of our study are (1) to analyze and interpret the spatial and temporal land use and land cover changes in BBW and (2) to determine nutrient, heavy metal, and bacterial contamination in the Brays Bayou. Water and sediment samples were collected from selected sampling locations along the Brays Bayou and analyzed for various nutrient and metal concentrations. Bacterial analysis was conducted to enumerate the fecal coliform bacteria in water samples. Landsat Thematic Mapper (TM) satellite images sampled from over three decades (1980–2010) for the BBW study area were processed and analyzed for land use and land cover changes. Our remote sensing analysis revealed that the BBW lost about 28.4% (9463 acres) vegetation during the period of 1984 to 2010. The loss in vegetative areas resulted in increased impervious surface areas. In sediment samples, increasing trends for Al, Cu, Fe, Pb, and Zn were observed towards the downstream of Brays Bayou. Lead concentrations were found at the highest concentration (70 mg/kg) in certain Brays Bayou sampling locations. Escherichia coli concentrations decreased towards the downstream of Brays Bayou and were found below 200 maximum probable numbers/100 ml. Integration of remote sensing along with the chemical and biological analysis helped to understand the impact of land cover changes on the bayou water quality.
Show more [+] Less [-]Faecal Indicator Bacteria: Groundwater Dynamics and Transport Following Precipitation and River Water Infiltration
2012
Faecal contamination of drinking water extracted from alluvial aquifers can lead to severe problems. River water infiltration can be a hazard for extraction wells located nearby, especially during high discharge events. The high dimensionality of river–groundwater interaction and the many factors affecting bacterial survival and transport in groundwater make a simple assessment of actual water quality difficult. The identification of proxy indicators for river water infiltration and bacterial contamination is an important step in managing groundwater resources and hazard assessment. The time resolution of microbial monitoring studies is often too low to establish this relationship. A proxy-based approach in such highly dynamic systems requires in-depth knowledge of the relationship between the variable of interest, e.g. river water infiltration, and its proxy indicator. In this study, continuously recorded physico-chemical parameters (temperature, electrical conductivity, turbidity, spectral absorption coefficient, particle density) were compared to the counts for faecal indicator bacteria, Escherichia coli and Enterococcus sp. obtained from intermittent sampling. Sampling for faecal indicator bacteria was conducted on two temporal scales: (a) routine bi-weekly monitoring over a month and (b) intense (bi-hourly) event-based sampling over 3 days triggered by a high discharge event. Both sampling set-ups showed that the highest bacterial concentrations occurred in the river. E. coli and Enterococcus sp. concentrations decreased with time and length of flow path in the aquifer. The event-based sampling was able to demonstrate differences in bacterial removal between clusters of observation wells linked to aquifer composition. Although no individual proxy indicator for bacterial contamination could be established, it was shown that a combined approach based on time-series of physico-chemical parameters could be used to assess river water infiltration as a hazard for drinking water quality management.
Show more [+] Less [-]Identification of an Assemblage of Indicator Organisms to Assess Timing and Source of Bacterial Contamination in Groundwater
2001
Conboy, M. J. | Goss, M. J.
Bacterial contamination of drinking water wells is a commonproblem in many rural areas. Some of this contamination may berelated to manure spreading or housing of livestock; another source is on-site septic systems. Current indicator organisms are able to detect the presence of fecal contamination, but where there may be more than one potential source of fecal material, the current indicators are unable to ascertain the origin. This laboratory investigation was undertaken to determine the longevity and reliability of a selected suite of indicator organisms. Total coliform, fecal coliform, fecal streptococci and Clostridium perfringens were monitoredin a simulated contaminated groundwater environment for 6 months. All four indicator organisms were present at the end of6 months. The number of fecal streptococi bacteria decreased most noticeably, allowing assessment of relative age of contamination. C. perfringens was found to be a reliableindicator of contamination from animal manure. Fecal material from 28 different animals and three septic systems were assessed for the presence of the indicator organisms. Totalcoliform, fecal coliform and fecal streptococci were present in the fecal material of all animals tested including reptiles.C. perfringens was detected in feces from all but two of the animals assessed. Using an assemblage of indicator organisms provides more information regarding source and timingof contamination than just testing for total coliform and fecalcoliform bacteria.
Show more [+] Less [-]