Refine search
Results 1-10 of 36
Contribution of a submerged membrane bioreactor in the treatment of synthetic effluent contaminated by Bisphenol-A: Mechanism of BPA removal and membrane fouling
2013
Seyhi, Brahima | Drogui, Patrick | Buelna, Gerardo | Azaïs, Antonin | Heran, Marc
A submerged membrane bioreactor has been operated at the laboratory scale for the treatment of a synthetic effluent containing Bisphenol-A (BPA). COD, NH4–N, PO4–P and BPA were eliminated respectively, at 99%, 99%, 61% and 99%. The increase of volumetric loading rate from 0 to 21.6 g/m3/d did not affect the performance of the MBR system. However, the removal rate decreased rapidly when the BPA loading rate increased above 21.6 g/m3/d. The adsorption process of BPA on the biomass was very well described by Freundlich and Langmuir isotherms. Subsequently, biodegradation of BPA occurred and followed the first order kinetic reaction, with a constant rate of 1.13 ± 0.22 h−1. During treatment, membrane fouling was reversible in the first 84 h of filtration, and then became irreversible. The membrane fouling was mainly due to the accumulation of suspended solid and development of biofilm on the membrane surface.
Show more [+] Less [-]Effects of local and spatial conditions on the quality of harvested rainwater in the Mekong Delta, Vietnam
2013
Wilbers, Gert-Jan | Sebesvari, Zita | Rechenburg, Andrea | Renaud, Fabrice G.
The objective of this study was to assess the quality of harvested rainwater in the Mekong Delta (MD), Vietnam for local (roof types, storage system and duration) and spatial (proximity of industry, main roads, coastline) conditions. 78 harvested rainwater samples were collected in the MD and analyzed for pH, turbidity, TDS, COD, nutrients (NH4, NO3, NO2, o-PO4), trace metals and coliforms. The results show that thatch roofs lead to an increase of pollutants like COD (max 23.2 mgl−1) and turbidity (max 10.1 mgl−1) whereas galvanized roofs lead to an increase of Zn (max 2.2 mgl−1). The other local and spatial parameters had no or only minor influence on the quality of household harvested rainwater. However, lead (Pb) (max. 16.9 μgl−1) and total coliforms (max. 102 500 CFU100 ml−1) were recorded at high concentrations, probably due to a variety of household-specific conditions such as rainwater storage, collection and handling practices.
Show more [+] Less [-]Monitoring of impact of anthropogenic inputs on water quality of mangrove ecosystem of Uran, Navi Mumbai, west coast of India
2013
Pawar, Prabhakar R.
Surface water samples were collected from substations along Sheva creek and Dharamtar creek mangrove ecosystems of Uran (Raigad), Navi Mumbai, west coast of India. Water samples were collected fortnightly from April 2009 to March 2011 during spring low and high tides and were analyzed for pH, Temperature, Turbidity, Total solids (TS), Total dissolved solids (TDS), Total suspended solids (TSS), Dissolved oxygen (DO), Biochemical oxygen demand (BOD), Carbon dioxide (CO2), Chemical oxygen demand (COD), Salinity, Orthophosphate (O-PO4), Nitrite–nitrogen (NO2–N), Nitrate–nitrogen (NO3–N), and Silicates. Variables like pH, turbidity, TDS, salinity, DO, and BOD show seasonal variations. Higher content of O-PO4, NO3–N, and silicates is recorded due to discharge of domestic wastes and sewage, effluents from industries, oil tanking depots and also from maritime activities of Jawaharlal Nehru Port Trust (JNPT), hectic activities of Container Freight Stations (CFS), and other port wastes. This study reveals that water quality from mangrove ecosystems of Uran is deteriorating due to industrial pollution and that mangrove from Uran is facing the threat due to anthropogenic stress.
Show more [+] Less [-]The influence of Corexit 9500A and weathering on Alaska North Slope crude oil toxicity to the ammonia oxidizing bacterium, Nitrosomonas europaea
2013
Radniecki, Tyler S. | Schneider, Margaret C. | Semprini, Lewis
The toxicity of the water associated fraction (WAF) of Alaska North Slope Crude oil (ANSC), Corexit 9500A and the dispersant enhanced WAF (DEWAF) of ANSC:Corexit 9500A mixtures were examined on the model ammonia oxidizing bacterium, Nitrosomonas europaea. Corexit 9500A was not toxic at environmentally relevant concentrations. Corexit 9500A greatly increased the toxicity of ANSC by increasing the chemical oxygen demand (COD) of the DEWAF. However, a majority of the DEWAF compounds were not toxic to N. europaea. Weathered WAF and DEWAF were not toxic to N. europaea even though their COD did not change compared to non-weathered controls, suggesting that toxicity was due to a small volatile fraction of the ANSC. The over-expression of the NE1545 gene, a marker for aromatic hydrocarbon exposure, in N. europaea cells exposed to WAF and DEWAF suggests that aromatic hydrocarbons are bioavailable to the cells and may play a role in the observed toxicity.
Show more [+] Less [-]Impact of Water Quality Parameters on the Clogging of Vertical-Flow Constructed Wetlands Treating Urban Wastewater
2013
Sani, Abdulkadir | Scholz, Miklas | Babatunde, Akintunde | Wang, Yu
In theory, biological and physical clogging, induced as a result of potentially excessive formation of biomass from degradation of pollutants and retention of inert suspended fine particles, respectively, should result in a decrease of treatment performance. However, some wetlands are not prone to clogging in practice. The aim of this study was to compare the impact of different design (aggregate size) and operational (contact time, empty time and chemical oxygen demand [COD] loading) variables on the treatment efficiency and clogging processes. Different vertical-flow constructed wetlands were constructed and operated from June 2011 until June 2012. Data from June 2011 (setting-up period) were not used. The filter with the highest COD loading performed the worst in terms of outflow COD concentration (120 mg/l) but best in terms of COD load reduction (61 %). The wetland with the largest aggregate size had the lowest mean nitrate-nitrogen outflow concentration of 1.2 mg/l. However, the results were similar regardless of aggregate size (10 versus 20 mm) and resting time (24 versus 48 h) for most water quality variables. However, different COD inflow concentrations (COD of 146 mg/l versus COD of 312 mg/l) had a significant (p < 0.05) impact on the treatment performance for COD, ammonia-nitrogen, ortho-phosphate-phosphorus and suspended solids (SS). Serious clogging phenomena impacting negatively on the treatment performance were not observed for any columns. However, a small aggregate diameter, a short contact time, a long resting time and a low COD inflow concentration were most beneficial in reducing SS accumulation within the wetland filters. © 2013 Springer Science+Business Media Dordrecht.
Show more [+] Less [-]The Impact of Process Sequences on Pollutant Removal Efficiencies in Tannery Wastewater Treatment
2013
Ayoub, George M. | Hamzeh, Abeer | Al-Hindi, Mahmoud
A laboratory-scale study was conducted to determine the removal efficiencies of nine contaminants from a tannery wastewater using a number of physicochemical processes. Coagulation–flocculation using bittern as coagulant, oxidation-utilizing ozone, and adsorption using activated carbon were applied separately and in different sequences. Jar tests were utilized to conduct the experimental work. Except for arsenic, the highest removal efficiencies were recorded when coagulation/flocculation was conducted on the alkalized samples using a bittern dose of 5 mL/L. Activated carbon adsorption improved removal efficiencies of several contaminants. The coagulation/flocculation–adsorption sequence using the optimum dose of 5 mL/L of bittern resulted in high removal efficiencies for total suspended solids (TSS) (97 % ± 1), apparent color (100 % ± 0), turbidity (97 % ± 1), total nitrogen (86 % ± 1), and chromium (100 % ± 0). On the other hand, the same sequence resulted in moderate removal efficiencies for chemical oxygen demand (COD) (72 % ± 7) and total phosphorus (74 % ± 5) and relatively low removals for biochemical oxygen demand (BOD) (55 % ± 10) and arsenic (42 % ± 14). The removal efficiencies for the different tested sequences demonstrated that each sequence did improve the removal efficiencies for most of the parameters tested and consequently, the quality of tannery effluent. However, no single optimum sequence was capable of attaining high removal efficiencies for all nine parameters.
Show more [+] Less [-]Investigation on pretreatment of centrifugal mother liquid produced in the production of polyvinyl chloride by air-Fenton technique
2013
Sun, Yingying | Hua, Xiuyi | Ge, Rui | Guo, Aitong | Guo, Zhiyong | Dong, Deming | Sun, Wentian
Centrifugal mother liquid (CML) is one of the main sources of wastewater produced during the production of polyvinyl chloride in chlor-alkali industry. CML is a typical poorly biodegradable organic wastewater, containing many kinds of refractory pollutants. Specifically, it contains dissolved refractory polymers, especially polyvinyl alcohol (PVA), which can pass though the biotreatment processes and clog the membranes used for further treatment. In this study, to ensure the CML applicable to biotreatment and membrane treatment, a novel efficient and mild technique, air-Fenton treatment, was employed as a pretreatment technique to improve biodegradability of the CML and to break down the polymers in the CML. Firstly, the technique was optimized for the CML treatment by optimizing the main parameters, including the dosage of ferrous sulfate, initial pH of the wastewater, [H2O2]/[Fe(2+)], aeration rate, reaction time, and temperature, based on removal efficiency of COD and PVA from the CML. Then, the optimized technique was tested and evaluated. The results indicated that under the optimized conditions, the air-Fenton treatment could remove 66, 98, and 55 % of the COD, PVA, and TOC, respectively, from the CML. After the treatment, biodegradability of the wastewater increased significantly (BOD/COD increased from 0.31 to 0.68), and almost all of the PVA polymers were removed or broken down. Meanwhile, concentration of the remaining iron ions, which were added during the treatment, was also quite low (only 2.9 mg/L). Furthermore, most of the suspended materials and ammonia nitrogen, and some of the phosphorus in the wastewater were removed simultaneously.
Show more [+] Less [-]Comparison of Organic Matter Removal from Synthetic and Real Wastewater in a Laboratory-Scale Soil Aquifer Treatment System
2013
Ak, Mesut | Gunduz, Orhan
In this study, the performance of a laboratory-scale soil aquifer treatment (SAT) system was investigated and treatability studies were done in order to determine organic matter removal from synthetic wastewater (SWW) and secondary treated real wastewater (RWW). The SAT system was constructed in laboratory conditions and treatability studies were conducted using soil columns, which were packed with silt loam soil samples. Each column was equipped with a series of ports at multiple depths from soil surface (10, 20, 30, 50, and 75 cm) to collect water samples. Two operational cycles were applied to represent the influence of different wetting and drying periods during wastewater application. Dissolved oxygen, chemical oxygen demand (COD), and total organic carbon (TOC) concentrations were measured in all samples. Average removal values of 61.4 % (COD) and 68.2 % (TOC) were achieved by in SWW and of 58.3 % (COD) and 51.1 % (TOC) in RWW in 55 and 25 weeks of operation, respectively. These results indicated that the performance of the columns operated with SWW was better than the performance of the columns operated with RWW. In essence, the easily biodegradable portion of organic matter was quickly consumed by microorganisms in the first 10 cm of the columns where oxygen levels peaked. Complex organic compounds that are likely to be found in RWW could thus be removed when longer residence times were achieved through the columns. When the removal performances achieved with different operating cycles were compared for each wastewater, it could be seen that longer wetting and longer drying periods yielded higher removal efficiencies in RWW and vice versa in SWW. © 2013 Springer Science+Business Media Dordrecht.
Show more [+] Less [-]Evaluation of the Physical–Chemical Characteristics of Wastewater After Disinfection with Peracetic Acid
2013
Cavallini, Grasiele Soares | de Campos, Sandro Xavier | de Souza, Jeanette Beber | de Sousa Vidal, Carlos Magno
The use of peracetic acid (PAA) in the disinfection of sanitary effluents has been proposed by various authors. However, there are still doubts about its influence on the physical-chemical characteristics of the effluent after application. In the present study, it was observed that the composition of PAA leads to an increase in organic material, resulting in an increase of approximately 20 mg/L in the chemical oxygen demand of the effluent for every 10 mg/L of PAA applied. According to the kinetic tests, the degradation of PAA in the effluent was represented by a first-order reaction and its half-life in the effluent was estimated at 79 min. The formation of by-products resulting from degradation of PAA in the effluent was evaluated by considering by-products already detected by other authors in disinfection trials, these being nonanal, decanal, chlorophenols, and 1-methoxy-4-methylbenzene, which were not observed in the effluent being studied after application of PAA at a dosage of 10 mg/L. © 2013 Springer Science+Business Media Dordrecht.
Show more [+] Less [-]Electrochemical Degradation of the Reactive Red 141 Dye Using a Boron-Doped Diamond Anode
2013
Aquino, José Mario | Rocha-Filho, Romeu C. | Rodrigo, Manuel A. | Sáez, Cristina | Cañizares, Pablo
The electrochemical degradation of the Reactive Red 141 azo dye was done using a one-compartment filter-press flow cell with a boron-doped diamond anode. The response surface methodology (with a central composite design) was used to investigate the effect of current density (10–50 mA cm⁻²), pH (3–11), NaCl concentration ([NaCl]) (0–2.34 g L–¹), and temperature (15–55 °C) on the system’s performance. The charge required for 90 % decolorization (Q ⁹⁰), the fraction of chemical oxygen demand removal after 6 min of electrolysis (COD⁶), and the fraction of total organic carbon removal after 90 min of electrolysis (TOC⁹⁰) were used to model the obtained results. The lowest values of Q ⁹⁰ were attained at pH <4 in the presence of higher values of [NaCl] (>1.5 g L⁻¹), due to the electrogeneration of active chlorine, present mainly as HClO. The value of COD⁶ was not affected by the solution pH, but increased with [NaCl] up to 1.5 g L⁻¹. Higher temperatures (>40 °C) led to a decrease in COD⁶, as a consequence of side reactions. Higher values of TOC⁹⁰, which can be reached only with strong oxidants (such as ·OH and Cl·), were efficiently attained at low [NaCl] values (<0.7 g L⁻¹) in acidic solutions that inhibit the formation of ClO₃ ⁻ and ClO₄ ⁻. Finally, the obtained results allow inferring that most probably the mineralization of the dye starts with an attack on the chromophore group, followed by the degradation of intermediate species.
Show more [+] Less [-]