Refine search
Results 1-2 of 2
A typical derivative and byproduct of tetrabromobisphenol A: Development of novel high-throughput immunoassays and systematic investigation of their distributions in Taizhou, an e-waste recycling area in eastern China
2020
Environmental distribution and concentration of tetrabromobisphenol A bis- (2-hydroxyethyl) ether (TBBPA-DHEE) and tetrabromobisphenol A mono- (hydroxyethyl) ether (TBBPA-MHEE), are obscure due to the lack of available analytical methods. Here two novel immunoassays were established to systematically investigate their distributions in Taizhou, Eastern China. Five monoclonal antibodies against pollutants were generated with two designed haptens through animal immunization. After matched with different coating antigens/antibodies, ELISAs were established (LOD for TBBPA-DHEE, 0.12 ng/mL, based on OVA-M3/mAb-D4G6; LOD for TBBPA-MHEE, 0.79 ng/mL, based on OVA-M3/mAb-D2G6) and applied for investigation of their occurrences at a typical e-waste recycling area after 2-year samples collection, where the total 33 water, 32 soil and 16 biological samples were collected with the highest concentrations of 3.46 ng/mL, 2.76 ng/g (dry weight, dw) and 5.01 ng/g (dw), respectively. Meanwhile, our study also indicated that at the centralizing e-waste recycling sites the serious pollution for both chemicals still existed despite of various efforts. Besides, obvious improvements were observed at an abandoned e-waste recycling region treated and remedied for many years by the local Chinese government. These findings highlight the importance of policy decisions in treatment of pollutants to reduce organic pollutant-related health risks.
Show more [+] Less [-]Colloidal gold probe-based immunochromatographic assay for the rapid detection of lead ions in water samples
2010
Tang, Yong | Zhai, Yi-Fan | Xiang, Jun-Jian | Wang, Hong | Liu, Bin | Guo, Chang-Wei
One-step immunochromatographic assay (ICA) has been developed using colloidal gold-labeled monoclonal antibody probe for the rapid detection of lead ions in water samples. The ICA was based on the theory of competitive reactivity, and the results can be easily judged based on the presence or absence of a red colored test line with visual detection. Under optimal conditions, this method shows high detecting sensitivity with a LOD (limit of detection) of 50 ng/ml. Stability test indicates that the immunochromatographic strips are stable for 8 weeks at room temperature. During practical application, nanometer TiO2 is used to enrich the lead ions in water samples. The ICA is successfully applied in the measurement of lead ion concentrations in local water samples, and the results are highly consistent with that of ICP-MS. Detecting lead ions with ICA can be done within 4 min and is very useful for the rapid onsite testing.
Show more [+] Less [-]