Refine search
Results 1-2 of 2
Efficient retrieval of vegetation leaf area index and canopy clumping factor from satellite data to support pollutant deposition assessments
2006
Nikolov, N. | Zeller, K.
Canopy leaf area index (LAI) is an important structural parameter of the vegetation controlling pollutant uptake by terrestrial ecosystems. This paper presents a computationally efficient algorithm for retrieval of vegetation LAI and canopy clumping factor from satellite data using observed Simple Ratios (SR) of near-infrared to red reflectance. The method employs numerical inversion of a physics-based analytical canopy radiative transfer model that simulates the bi-directional reflectance distribution function (BRDF). The algorithm is independent of ecosystem type. The method is applied to 1-km resolution AVHRR satellite images to retrieve a geo-referenced data set of monthly LAI values for the conterminous USA. Satellite-based LAI estimates are compared against independent ground LAI measurements over a range of ecosystem types. Verification results suggest that the new algorithm represents a viable approach to LAI retrieval at continental scale, and can facilitate spatially explicit studies of regional pollutant deposition and trace gas exchange. The paper presents a physics-based algorithm for retrieval of vegetation LAI and canopy-clumping factor from satellite data to assist research of pollutant deposition and trace-gas exchange. The method is employed to derive a monthly LAI dataset for the conterminous USA and verified at a continental scale.
Show more [+] Less [-]Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water
2006
Vrana, B. (Branislav) | Mills, G.A. | Dominiak, E. | Greenwood, R.
An integrative passive sampler consisting of a C18 Empore® disk receiving phase saturated with n-octanol and fitted with low-density polyethylene diffusion membrane was calibrated for the measurement of time-weighted average concentrations of hydrophobic micropollutants, including polyaromatic hydrocarbons and organochlorine pesticides, in water. The effect of temperature and water turbulence on kinetic and thermodynamic parameters characterising the exchange of analytes between the sampler and water was studied in a flow-through system under controlled conditions. It was found that the absorption of test analytes from water to the sampler is related to their desorption to water. This allows for the in situ calibration of the uptake of pollutants using offload kinetics of performance reference compounds. The sampling kinetics are dependent on temperature, and for most of the tested analytes also on the flow velocity. Sampler–water partition coefficients did not significantly change with temperature.
Show more [+] Less [-]