Refine search
Results 1121-1130 of 7,290
Contribution of plasmidome, metal resistome and integrases to the persistence of the antibiotic resistome in aquatic environments Full text
2022
Di Cesare, Andrea | Sabatino, Raffaella | Yang, Ying | Brambilla, Diego | Li, Pu | Fontaneto, Diego | Eckert, Ester M. | Corno, Gianluca
Wastewater treatment plants (WWTPs) are among the main hotspots of antibiotic resistance genes (ARGs) in the environment. Previously, we demonstrated that, by increasing anthropogenic pollution, the antibiotic resistome persisted in the microbial community of rivers and lakes, independently by changes in community composition. In this study, we reanalysed the data to test for the relation of metal resistance genes (MRGs), plasmids, and integrons to the persistence of the antibiotic resistome. The experiment consisted in replicated co-cultures of riverine or lacustrine microbial communities and WWTP effluents in different proportions. Samples before (T0) and after a short period of incubation (TF) were collected and community metagenomic data were obtained by shotgun sequencing. The data were processed to annotate MRGs, plasmids, and integrases. The integrases stabilized in the aquatic environment following the degree of contamination with effluent water (in particular in one site), whereas MRGs and plasmids showed stochastic trajectories. These results confirm the potential correlation between integrons and anthropogenic pollution, and the reliability of intI1 as a pollution marker. Only in one site MRGs, plasmids, and ARGs were correlated, highlighting their partial contribution to the persistence of ARGs in surface waters.
Show more [+] Less [-]Toward a long-term monitoring program for seawater plastic pollution in the north Pacific Ocean: Review and global comparison Full text
2022
Shim, Won Joon | Kim, Seung-Kyu | Lee, Jongsu | Eo, Soeun | Kim, Ji-Su | Sun, Chengjun
Through a literature survey and meta-data analysis, monitoring methods and contamination levels of marine micro- and macroplastics in seawater were compared between the North Pacific and the world's other ocean basins. The minimum cut-off size in sampling and/or analysis of microplastics was crucial to the comparison of monitoring data. The North Pacific was most actively monitored for microplastics and showed comparatively high levels in the global context, while the Mediterranean Sea was most frequently monitored for macroplastics. Of the 65 extracted mean abundances of microplastics in seawater from the North Pacific, two (3.1%) exceeded the lowest predicted no-effect concentration (PNEC) proposed thus far. However, in the context of business-as-usual conditions, the PNEC exceedance probability may be expected to reach 27.7% in the North Pacific in 2100. The abundance of marine plastics in seawater, which reflects the current pollution status and marine organisms' waterborne exposure levels, is a useful indicator for marine plastic pollution. For regional and global assessments of pollution status across space and time, as well as assessment of ecological risk, two microplastic monitoring approaches are recommended along with their key aspects. Although microplastic pollution is closely linked with macroplastics, the monitoring data available for floating macroplastics and more extent to mesoplastics in most ocean basins are limited. A more specific framework for visual macroplastic survey (e.g. fixed minimum cut-off size, along with survey transect width and length according to survey vessel class) is required to facilitate data comparison. With the implementation of standardised methods, increased efforts are required to gather monitoring data for microplastics and—more importantly—floating macroplastics in seawater worldwide.
Show more [+] Less [-]Long-term exposure to PM2.5 aggravates pulmonary fibrosis and acute lung injury by disrupting Nrf2-mediated antioxidant function Full text
2022
Zhao, Chen | Pu, Wenyuan | Wazir, Junaid | Jin, Xiaolu | Wei, Lulu | Song, Shiyu | Su, Zhonglan | Li, Jiabin | Deng, Yijun | Wang, Hongwei
Epidemiological studies have indicated that exposure to ambient air-borne fine particulate matter (PM2.5) is associated with many cardiopulmonary diseases; however, the underlying pathological mechanisms of PM2.5-induced lung injury remain unknown. In this study, we aimed to assess the impact of acute or prolonged exposure to water-insoluble fractions of PM2.5 (PM2.5 particulate) on lung injury and its molecular mechanisms. Balb/c mice were randomly exposed to PM2.5 once (acute exposure) or once every three days for a total of 6 times (prolonged exposure). Lung, BALF and blood samples were collected, and pulmonary pathophysiological alterations were analyzed. Nrf2 knockout mice were adapted to assess the involvement of Nrf2 in lung injury, and transcriptomic analysis was performed to delineate the mechanisms. Through transcriptomic analysis and validation of Nrf2 knockout mice, we found that acute exposure to PM2.5 insoluble particulates induced neutrophil infiltration-mediated airway inflammation, whereas prolonged exposure to PM2.5 insoluble particulate triggered lung fibrosis by decreasing the transcriptional activity of Nrf2, which resulted in the downregulated expression of antioxidant-related genes. In response to secondary LPS exposure, prolonged PM2.5 exposure induced more severe lung injury, indicating that prolonged PM2.5 exposure induced Nrf2 inhibition weakened its antioxidative defense capacity against oxidative stress injury, leading to the formation of pulmonary fibrosis and increasing its susceptibility to secondary bacterial infection.
Show more [+] Less [-]Health benefits by attaining the new WHO air quality guideline targets in China: A nationwide analysis Full text
2022
Yang, Jun | Ma, Jinxiang | Sun, Qinghua | Han, Chunlei | Guo, Yuming | Li, Mengmeng
To reduce the high disease burden caused by air pollution, World Health Organization (WHO) issued a new air quality guideline (AQG) on the 22nd September 2021. A timely quantitative assessment of health benefits by meeting these targets is a key measure to advocate and inform national and regional disease control policies. We collected daily major air pollution data in 315 Chinese cities from the 1st January to the 31st December 2019, and the corresponding annual population and mortality rate in the whole population of each city. Then, the mortality benefits were estimated when daily air pollution levels attained WHO's new AQG targets (15 μg/m³ for PM₂.₅, 25 μg/m³ for NO₂ and 100 μg/m³ for O₃) in 315 Chinese cities and 31 provinces by using pollutant- and cause-specific concentration-response functions. In total, 134,025 (95%CI: 92,768; 173,029) air pollution-associated non-accidental deaths could be avoided in 315 Chinese cities in 2019 by attaining WHO's new AQG targets, with 43,800 (95%CI: 29,945; 55,616) avoidable deaths from PM₂.₅, 58,070 (95%CI: 45,333; 70,714) from NO₂, and 32,155 (95%CI: 17,490; 46,699) from O₃. Cardiovascular diseases and respiratory diseases accounted for 72,698 (95%CI: 46,561; 101,680) and 17,726 (95%CI: 8603; 26,925) avoidable deaths, respectively. Health benefits from reduction in air pollution levels were 99.26 avoided non-accidental deaths per million population at national level, ranging from 12.48 per million in Tibet to 166.26 per million in Hebei. These findings suggest that the compliance with the WHO updated AQG standards would save substantial amount of air pollution-related premature deaths in China. More stringent air pollution control and management measures are urgently warranted to reduce the disease burden from air pollutants in China, particularly for the worsening O₃ pollution.
Show more [+] Less [-]Associations of air pollution with COVID-19 positivity, hospitalisations, and mortality: Observational evidence from UK Biobank Full text
2022
Sheridan, Charlotte | Klompmaker, Jochem | Cummins, Steven | James, Peter | Fecht, Daniela | Roscoe, Charlotte
Individual-level studies with adjustment for important COVID-19 risk factors suggest positive associations of long-term air pollution exposure (particulate matter and nitrogen dioxide) with COVID-19 infection, hospitalisations and mortality. The evidence, however, remains limited and mechanisms unclear. We aimed to investigate these associations within UK Biobank, and to examine the role of underlying chronic disease as a potential mechanism. UK Biobank COVID-19 positive laboratory test results were ascertained via Public Health England and general practitioner record linkage, COVID-19 hospitalisations via Hospital Episode Statistics, and COVID-19 mortality via Office for National Statistics mortality records from March–December 2020. We used annual average outdoor air pollution modelled at 2010 residential addresses of UK Biobank participants who resided in England (n = 424,721). We obtained important COVID-19 risk factors from baseline UK Biobank questionnaire responses (2006–2010) and general practitioner record linkage. We used logistic regression models to assess associations of air pollution with COVID-19 outcomes, adjusted for relevant confounders, and conducted sensitivity analyses. We found positive associations of fine particulate matter (PM₂.₅) and nitrogen dioxide (NO₂) with COVID-19 positive test result after adjustment for confounders and COVID-19 risk factors, with odds ratios of 1.05 (95% confidence intervals (CI) = 1.02, 1.08), and 1.05 (95% CI = 1.01, 1.08), respectively. PM 2.5 and NO 2 were positively associated with COVID-19 hospitalisations and deaths in minimally adjusted models, but not in fully adjusted models. No associations for PM₁₀ were found. In analyses with additional adjustment for pre-existing chronic disease, effect estimates were not substantially attenuated, indicating that underlying chronic disease may not fully explain associations. We found some evidence that long-term exposure to PM₂.₅ and NO₂ was associated with a COVID-19 positive test result in UK Biobank, though not with COVID-19 hospitalisations or deaths.
Show more [+] Less [-]Inhalation bioaccessibility of multi-class organic pollutants associated to atmospheric PM2.5: Correlation with PM2.5 properties and health risk assessment Full text
2022
Sánchez-Piñero, Joel | Novo-Quiza, Natalia | Pernas-Castaño, Cristina | Moreda-Piñeiro, Jorge | Muniategui-Lorenzo, Soledad | López-Mahía, Purificación
Inhalation exposure to fine particulate matter (PM₂.₅) represents a global concern due to the adverse effects in human health. In the last years, scientific community has been adopted the assessment of the PM₂.₅-bound pollutant fraction that could be released (bioaccessible fraction) in simulated lung fluids (SLFs) to achieve a better understanding of PM risk assessment and toxicological studies. Thus, bioaccessibility of 49 organic pollutants, including 18 polycyclic aromatic hydrocarbons (PAHs), 12 phthalate esters (PAEs), 11 organophosphorus flame retardants (OPFRs), 6 synthetic musk compounds (SMCs) and 2 bisphenols in PM₂.₅ samples was evaluated. The proposed method consists of a physiologically based extraction test (PBET) by using artificial lysosomal fluid (ALF) to obtain bioaccessible fractions, followed by a vortex-assisted liquid-liquid microextraction (VALLME) and a final analysis by programmed temperature vaporization-gas chromatography-tandem mass spectrometry (PTV-GC-MS/MS). The highest inhalation bioaccessibility ratio was found for bisphenol A (BPA) with an average of 83%, followed by OPFRs, PAEs and PAHs (with average bioaccessibilities of 68%, 41% and 34%, respectively). Correlations between PM₂.₅ composition (major ions, trace metals, equivalent black carbon (eBC) and UV-absorbing particulate matter (UVPM)) and bioaccessibility ratios were also assessed. Principal Component Analysis (PCA) suggested that PAHs, PAES and OPFRs bioaccessibility ratios could be positively correlated with PM₂.₅ carbonaceous content. Furthermore, both inverse and positive correlations on PAHs, PAEs and OPFRs bioaccessibilites could be accounted for some major ions and metal (oid)s associated to PM₂.₅, whereas no correlations comprising considered PM₂.₅ major ions and metal (oid)s contents and BPA bioaccessibility was observed. In addition, health risk assessment of target PM₂.₅-associated PAHs via inhalation was assessed in the study area considering both total and bioaccessible concentrations, being averaged human health risks within the safe carcinogenic and non-carcinogenic levels.
Show more [+] Less [-]Contaminants of emerging concern in marine areas: First evidence of UV filters and paraben preservatives in seawater and sediment on the eastern coast of Tunisia Full text
2022
Fenni, Ferdaws | Sunyer-Caldú, Adrià | Ben Mansour, Hedi | Díaz-Cruz, M. Silvia
Contaminants of emerging concern in marine areas: First evidence of UV filters and paraben preservatives in seawater and sediment on the eastern coast of Tunisia Full text
2022
Fenni, Ferdaws | Sunyer-Caldú, Adrià | Ben Mansour, Hedi | Díaz-Cruz, M. Silvia
UV filters (UVFs) and paraben preservatives (PBs) are widely used components in many personal care products. However, there has been a rising concern for their endocrine-disrupting effects on wildlife once they reach aquatic ecosystems via recreative activities and wastewater treatment plants effluents. This study addresses UVFs and PBs occurrence in seawater and sediment impacted by tourism and sewage discharges along the coast of Mahdia, center East Tunisia. Samples of water and sediment were collected for 6 months from 3 coastal areas. Among the 14 investigated UVFs, 8 were detected in seawater and 4 were found in sediment. All PBs were present in seawater and only methylparaben (MePB) was detected in sediment. Benzophenone-3 (oxybenzone, BP3), benzocaine (EtPABA), and MePB were present in all water samples with concentrations in the ranges 16.4–66.9, 7.3–37.7, and 17.6–222 ng/L, respectively. However, the highest value, 1420 ng/L, corresponded to octinoxate (EHMC). In sediments, avobenzone (AVO), 4-methyl benzylidene camphor (4MBC), EHMC, 5-methyl-1-H-benzotriazole (MeBZT), and MePB were detected at concentrations within the range 1.1–17.6 ng/g dw, being MePB the most frequently detected (89%). MePB and MBZT presented the highest sediment-water partition coefficients and MePB also showed a positive correlation with total suspended solids’ water content. Overall, pollutants concentrations remained rather constant along the sampling period, showing little seasonal variation. This study constitutes the first monitoring of UVFs and PBs on the Tunisian coastline and provides occurrence data for reference in further surveys in the country.
Show more [+] Less [-]Contaminants of emerging concern in marine areas: First evidence of UV filters and paraben preservatives in seawater and sediment on the eastern coast of Tunisia Full text
2022
Fenni, Ferdaws | Sunyer-Caldú, Adrià | Ben Mansour, Hedi | Diaz-Cruz, Silvia | Ministerio de Ciencia e Innovación (España) | 0000-0001-7936-9828 | 0000-0003-3331-4076 | Consejo Superior de Investigaciones Científicas [https://ror.org/02gfc7t72]
UV filters (UVFs) and paraben preservatives (PBs) are widely used components in many personal care products. However, there has been a rising concern for their endocrine-disrupting effects on wildlife once they reach aquatic ecosystems via recreative activities and wastewater treatment plants effluents. This study addresses UVFs and PBs occurrence in seawater and sediment impacted by tourism and sewage discharges along the coast of Mahdia, center East Tunisia. Samples of water and sediment were collected for 6 months from 3 coastal areas. Among the 14 investigated UVFs, 8 were detected in seawater and 4 were found in sediment. All PBs were present in seawater and only methylparaben (MePB) was detected in sediment. Benzophenone-3 (oxybenzone, BP3), benzocaine (EtPABA), and MePB were present in all water samples with concentrations in the ranges 16.4-66.9, 7.3-37.7, and 17.6-222 ng/L, respectively. However, the highest value, 1420 ng/L, corresponded to octinoxate (EHMC). In sediments, avobenzone (AVO), 4-methyl benzylidene camphor (4MBC), EHMC, 5-methyl-1-H-benzotriazole (MeBZT), and MePB were detected at concentrations within the range 1.1-17.6 ng/g dw, being MePB the most frequently detected (89%). MePB and MBZT presented the highest sediment-water partition coefficients and MePB also showed a positive correlation with total suspended solids' water content. Overall, pollutants concentrations remained rather constant along the sampling period, showing little seasonal variation. This study constitutes the first monitoring of UVFs and PBs on the Tunisian coastline and provides occurrence data for reference in further surveys in the country. | The authors acknowledge the Generalitat de Catalunya (2017-SGR-1404), the Spanish Ministry of Science and Innovation (CEX 2018-000794-S) and the Ministry of Higher Education and Scientific Research of Tunisia. | Peer reviewed
Show more [+] Less [-]Long-distance transport of per- and polyfluoroalkyl substances (PFAS) in a Swedish drinking water aquifer Full text
2022
Sörengård, Mattias | Bergström, Sofia | McCleaf, Philip | Wiberg, Karin | Ahrens, Lutz
Long-distance transport of per- and polyfluoroalkyl substances (PFAS) in a Swedish drinking water aquifer Full text
2022
Sörengård, Mattias | Bergström, Sofia | McCleaf, Philip | Wiberg, Karin | Ahrens, Lutz
Use of per- and polyfluoroalkyl substance (PFAS)-containing aqueous film-forming foams (AFFF) at firefighting training sites (FFTS) has been linked to PFAS contamination of drinking water. This study investigated PFAS transport and distribution in an urban groundwater aquifer used for drinking water production that has been affected by PFAS-containing AFFF. Soil, sediment, surface water and drinking water were sampled. In soil (n = 12) at a FFTS with high perfluorooctane sulfonate (PFOS) content (87% of ∑PFAS), the ∑PFAS concentration (n = 26) ranged from below detection limit to 560 ng g⁻¹ dry weight. In groundwater (n = 28), the ∑PFAS concentration near a military airbase FFTS reached 1000 ng L⁻¹. Principal component analysis (PCA) identified the military FFTS as the main source of PFAS contamination in drinking water wellfields >10 km down-gradient. Groundwater samples taken close to the military FFTS site showed no ∑PFAS concentration change between 2013 and 2021, while a location further down-gradient showed a transitory 99.6% decrease. Correlation analysis on PFAS composition profile indicated that this decrease was likely caused by dilution from an adjacent conflating aquifer. ∑PFAS concentration reached 15 ng L⁻¹ (PFOS 47% and PFHxS 41% of ∑PFAS) in surface river water (n = 6) and ranged between 1 ng L⁻¹ and 8 ng L⁻¹ (PFHxS 73% and PFBS 17% of ∑PFAS) in drinking water (n = 4). Drinking water had lower PFAS concentrations than the wellfields due to PFAS removal at the water treatment plant. This demonstrates the importance of monitoring PFAS concentrations throughout a groundwater aquifer, to better understand variations in transport from contamination sources and resulting impacts on PFAS concentrations in drinking water extraction areas.
Show more [+] Less [-]Long-distance transport of per- and polyfluoroalkyl substances (PFAS) in a Swedish drinking water aquifer Full text
2022
Sörengård, Mattias | Bergström, Sofia | McCleaf, Philip | Wiberg, Karin | Ahrens, Lutz
Use of per-and polyfluoroalkyl substance (PFAS)-containing aqueous film-forming foams (AFFF) at firefighting training sites (FFTS) has been linked to PFAS contamination of drinking water. This study investigated PFAS transport and distribution in an urban groundwater aquifer used for drinking water production that has been affected by PFAS-containing AFFF. Soil, sediment, surface water and drinking water were sampled. In soil (n = 12) at a FFTS with high perfluorooctane sulfonate (PFOS) content (87% of sigma PFAS), the sigma PFAS concentration (n = 26) ranged from below detection limit to 560 ng g(-1)dry weight. In groundwater (n = 28), the sigma PFAS concentration near a military airbase FFTS reached 1000 ng L-1. Principal component analysis (PCA) identified the military FFTS as the main source of PFAS contamination in drinking water wellfields > 10 km down-gradient. Groundwater samples taken close to the military FFTS site showed no sigma PFAS concentration change between 2013 and 2021, while a location further down-gradient showed a transitory 99.6% decrease. Correlation analysis on PFAS composition profile indicated that this decrease was likely caused by dilution from an adjacent conflating aquifer. sigma PFAS concentration reached 15 ng L-1 (PFOS 47% and PFHxS 41% of sigma PFAS) in surface river water (n = 6) and ranged between 1 ng L-1 and 8 ng L-1(PFHxS 73% and PFBS 17% of sigma PFAS) in drinking water (n = 4). Drinking water had lower PFAS concentrations than the wellfields due to PFAS removal at the water treatment plant. This demonstrates the importance of monitoring PFAS concentrations throughout a groundwater aquifer, to better understand variations in transport from contamination sources and resulting impacts on PFAS concentrations in drinking water extraction areas.
Show more [+] Less [-]Study of the joint action of multi-component mixtures based on parameter σ2(k∙ECx) characterizing the shape difference of concentration-response curves Full text
2022
Wang, Na | Zhang, Jingkun | Ma, Xiaoyan | Zhang, Huanle | Sun, Jiajing | Wang, Xiaochang | Zhou, Jinhong | Wang, Jiaxuan | Ge, Chengmin
A previous study has revealed that the parameter k∙ECₓ, characterizing the shape of concentration-response curves (CRCs), could predict the combined toxicity of binary mixtures. This study further explored the predictability of multi-component mixtures. Eleven component mixtures were designed using the uniform design ray, and the acute toxicity of the eleven environmental pollutants and their mixtures to Vibrio fischeri was determined using microplate toxicity analysis. We used independent action (IA) and the effect residual ratio (ERRₓ) models to evaluate the combined toxicity of multi-component mixtures and ascertain the functional relationship between σ²₍ₖ∙ECₓ₎, a parameter characterizing the CRC morphological difference of multi-component mixtures, and combined toxicity. The variance σ²₍ₖ∙ECₓ₎ of each component characteristic parameter of multi-component mixtures gradually increased in the concentration range, and the relationship between σ²₍ₖ∙ECₓ₎ and ERRₓ was consistent with the exponential function. The literature verification showed that this rule is generally applicable to the acute toxicity of multi-component mixtures to luminescent bacteria. The exponential function showed the variation rule of the joint action of multi-component mixtures. In the present study, the joint toxicity of multi-component mixtures can be predicted from single toxicity and small amount of multiple toxicity, circumventing complex multi-component toxicity experiments.
Show more [+] Less [-]Microwave-induced steam distillation (MISD) remediation in petroleum hydrocarbon-contaminated sites: From process improvement to pilot application Full text
2022
Xue, Zhenkun | Zuo, Rui | Ding, Fei | Wu, Ziyi | Pan, Minghao | Cai, Weihai | Xu, Yunxiang | Wang, Jinshen
The process improvement, a pilot remediation test and the decontamination mechanism of microwave-induced steam distillation (MISD) for petroleum hydrocarbons (PHs) removal were conducted. Processes of multistage steam distillation and carbon reinforcement were compared to determine the best remediation process. Pilot project was then carried out to explore the applicability of MISD in site-scale remediation. The remediation efficiency, procedures and influencing factors of site-scale MISD project were studied by monitoring variations of soil moisture, temperature and PHs concentrations. Furthermore, the decontamination mechanisms of PHs were clarified based on kinetic analysis. The results showed that the multistage steam distillation could improve 10%∼15% remediation efficiency, and the carbon reinforcement could shorten remediation duration of each steam distillation stage by 50%. Pilot MISD project adopted multistage steam distillation process and went through four (initial, rapid heating-up, gentle heating-up and quasi-equilibrium) remediation stages (overall temperature ≤100 °C). The final PHs removal rate was about 60%, which would get better with greater proportion of low boiling points components and stronger vapor extraction. Kinetic studies showed that PHs was removed by steam stripping and limited by intraparticle diffusion in the “steam distillation zone”, while local high temperature (>100 °C) greatly improved PHs volatilization and provided activation energy for PHs desorbed and degraded in the “selective heating zone".
Show more [+] Less [-]