Refine search
Results 101-110 of 1,146
Emitter clogging when using water from a tributary of the Bogotá River in Colombia | Taponamiento de goteros utilizando agua de un afluente del río Bogotá en Colombia Full text
2016
Almario-Narváez, Johana | Vélez-Sánchez, Javier Enrique | Molina-Ochoa, María Jaqueline
Emitter clogging when using water from a tributary of the Bogotá River in Colombia | Taponamiento de goteros utilizando agua de un afluente del río Bogotá en Colombia Full text
2016
Almario-Narváez, Johana | Vélez-Sánchez, Javier Enrique | Molina-Ochoa, María Jaqueline
An experiment was conducted to study the behavior of three types of emitters used in Colombia under real-work conditions using water from the Neusa River, a tributary of the Bogotá River. The emitters included: an in-line turbulent-flow emitter (E1), an integrated turbulent-flow emitter (E2), and an integrated self-regulated turbulent-flow emitter (E3). The operation and quality of the emitters were evaluated taking into account the flow decrease trend over time (RF), the flow reduction percentage of the emitters (qr), the coefficient of variation (Cv), the Christiansen uniformity coefficient (CU), and the emission uniformity (EU). The results indicated that the water quality in general affected the performance of the emitters over time, depending on the characteristics and properties of the emitters. The EU and CU decreased in the three emitter types as the experiment progressed and the Cv and qr increased. The E2 emitter showed a lower Cv and qr and a higher CU and EU than the E1 and E3 emitters. | Se realizó un experimento para estudiar el comportamiento de tres tipos de emisores utilizados en Colombia en condiciones de operación real, tomando como fuente de agua el río Neusa afluente del río Bogotá. Los emisores utilizados fueron: gotero en línea de flujo turbulento (E1), gotero integrado de flujo turbulento (E2) y gotero integrado de flujo turbulento autor-regulado (E3). El funcionamiento y calidad de los emisores fue evaluado teniendo en cuenta: la tendencia de diminución del caudal en el tiempo (RF), la reducción de caudal del emisor en porcentaje (qr), el coeficiente de variación (Cv), el coeficiente de uniformidad de Christiansen (CU) y la uniformidad de emisión (EU). Los resultados muestran como la calidad del agua afectó el desempeño del gotero a través del tiempo, dependiendo de las características y propiedades del emisor. La EU y el CU en los tres tipos de emisores disminuyó a medida que avanzó la experimentación y el Cv y qr, aumentaron. El emisor tipo E2, mostró menores Cv y qr y un mayor CU, EU que los emisores tipo E1 y E3, respectivamente.
Show more [+] Less [-]Emitter clogging when using water from a tributary of the Bogota River in Colombia Full text
2016
Johana Almario-Narváez | Javier Enrique Vélez-Sánchez | María Jaqueline Molina-Ochoa
An experiment was conducted to study the behavior of three types of emitters used in Colombia under real-work conditions using water from the Neusa River, a tributary of the Bogota River. The emitters included: an in-line turbulent-flow emitter (E1), an integrated turbulent-flow emitter (E2), and an integrated self-regulated turbulent-flow emitter (E3). The operation and quality of the emitters were evaluated taking into account the flow decrease trend over time (RF), the flow reduction percentage of the emitters (qr), the coefficient of variation (Cv), the Christiansen uniformity coefficient (CU), and the emission uniformity (EU). The results indicated that the water quality in general affected the performance of the emitters over time, depending on the characteristics and properties of the emitters. The EU and CU decreased in the three emitter types as the experiment progressed and the Cv and qr increased. The E2 emitter showed a lower Cv and qr and a higher CU and EU than the E1 and E3 emitters.
Show more [+] Less [-]Perspectivas sobre uso de agua en el sector minero metalúrgico Full text
2016
Revisa las condiciones sobre la utilización y aprovechamiento del agua en la legislación peruana con énfasis de sus implicancias en el sector minero.
Show more [+] Less [-]Tratamento de água para abastecimento utilizando elementos filtrantes de madeira Full text
2016
Müller, Laura Cecilia | Sens, Mauricio Luiz | Mondardo, Renata Iza | Universidade Federal de Santa Catarina
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2016. | A presente pesquisa investiga a aplicação das madeiras Pinus elliottii (pinus) e Drepanostachyum falcatum (bambu) como elementos filtrantes no tratamento de água para abastecimento descentralizado. Essa linha de pesquisa é inovadora, visto que existem poucas publicações sobre esse assunto a nível mundial. Esse trabalho busca dar continuidade a outros estudos sobre filtração em madeira, realizados no Laboratório de Potabilização das Águas (LAPOA), da Universidade Federal de Santa Catarina (UFSC). Os experimentos foram realizados envolvendo as seguintes etapas: 1) Caracterização das espécies por imagens obtidas por microscopia eletrônica de varredura (MEV); 2) Ensaios de adsorção do azul de metileno em serragem; 3) Ensaios de filtração frontal, aplicando as espécies pinus e bambu como elementos filtrantes. Os resultados demonstraram que as dimensões das estruturas que permitem a passagem de água na madeira pinus são menores que no bambu. O valor estimado do pH de carga superficial da serragem de pinus foi de 4,9 e do bambu de 5,9, o que indica que para adsorção de substâncias catiônicas o pH da solução deve ser maior que o pH de carga superficial do adsorvente a ser utilizado. A máxima capacidade adsortiva estimada para adsorção do azul de metileno em serragem do pinus foi de 47 mg L-1 e do bambu de 38 mg L-1 a 35 °C e pH 6,5. Ambos os adsorventes testados seguem o modelo cinético de pseudosegunda ordem e o modelo da isoterma de Langmuir. Sendo o processo de adsorção favorável segundo o fator de separação (0 < RL < 1) obtido pelos parâmetros de Langmuir. Segundo o modelo de Arrhenius, a energia de ativação (88 kJ mol-1) obtida para o adsorvente pinus representa um processo químico. Os elementos filtrantes de pinus promoveram maior remoção de turbidez (de 88 % a 98 %) quando comparado aos de bambu (máxima de 98 %), com turbidez máxima de 2,2 uT para o pinus. Isso possivelmente ocorreu devido ao menor diâmetro das estruturas anatômicas do pinus quando comparado ao bambu. Observou-se passagem de substâncias orgânicas para a água produzida pelos elementos filtrantes, por meio das análises de absorbância (? = 254 nm) (aumento de até 428 %) e COT (aumento de até 3280 %). O comprimento dos elementos filtrantes influenciou na qualidade da água produzida pelo bambu, o que não ocorreu na madeira pinus, fato que pode ser explicado pela diferença entre as estruturasanatômicas que promovem a retenção de turbidez, no pinus (margos, pontoações e traqueídeos), e no bambu (vasos metaxilema). Por fim, o pinus foi o elemento filtrante que apresentou melhor eficiência na remoção de turbidez, e também nos ensaios de adsorção do azul de metileno nesta pesquisa.<br> | Abstract : This research investigates the use of wood Pinus elliottii (pine) and Drepanostachyum falcatum (bamboo) as filter elements in decentralized water supply treatment. This line of research is innovative, since there are few publications on this subject worldwide. This work aims to continue further studies of filtration in wood, carried out in the Laboratório de Potabilização das Águas (LAPOA), in Universidade Federal de Santa Catarina (UFSC). The experiments were performed in the following steps: 1) Characterization of species by images obtained by scanning electron microscopy (SEM); 2) Methylene blue adsorption tests on sawdust; 3) Front flow filtration tests, applying the pine and the bamboo as filter elements. The results showed that the dimensions of the structures that allow the passage of water in the pine are smaller than in the bamboo. The estimated value of the zero charge pH of pine sawdust was 4.9 and of bamboo 5.9, indicating that for adsorption of cationic substances the pH of the solution must be greater than the zero charge pH of the adsorbent to be used. The maximum adsorption capacity estimated for methylene blue adsorption in pine sawdust was 47 mg L-1 and 38 mg L-1 in bamboo at 35 °C and pH 6.5. Both absorbent tested follow the kinetic model of pseudo second order and the Langmuir isotherm model. The adsorption process is favorable according to the separation factor (0 <RL <1) obtained by the Langmuir parameters. According to the Arrhenius model, the activation energy (88 kJ mol-1) obtained for the adsorbent pine represents a chemical process. The pine filter elements promote higher turbidity removal (88 % to 98 %) when compared to the bamboo?s (maximum 98 %), with a maximum turbidity of 2.2 NTU for pine. This possibly occurred due to the smaller diameter of the anatomical structures of pine compared to bamboo. It was observed the passage of organic substances to the water produced by the filter elements through analysis of absorbance (? = 254 nm) (increase of up to 428 %) and TOC (increase of up to 3280 %). The length of the filter elements influenced the quality of water produced by the bamboo, which did not occur in the pine wood. This can be explained by the difference between the anatomical structures that promote the retention of turbidity in pine (Margos, pits and tracheids) and in the bamboo (metaxylem vessels). Finally, the pine filter element showed the best efficiency in the removal of turbidity, and also in the methylene blue adsorption experiments in this study.
Show more [+] Less [-]Uso de água residuária da piscicultura no cultivo de alface Full text
2016
Guimarães, Isaías P. | Oliveira, Francisco de A. de | Torres, Salvador B. | Pereira, Francisco E. C. B. | França, Francisco D. de | Oliveira, Mychelle K. T. de
Calidad del agua subterránea: acuífero sur de Quintana Roo, México Full text
2016
Sánchez, Joan Alberto | Álvarez, Teresa | Pacheco, Julia Guadalupe | Carrillo, Laura | González, Roger Amílcar
Calidad del agua subterránea: acuífero sur de Quintana Roo, México Full text
2016
Sánchez, Joan Alberto | Álvarez, Teresa | Pacheco, Julia Guadalupe | Carrillo, Laura | González, Roger Amílcar
Abstract: This study was conducted in order to know the status of the groundwater quality of the aquifer south of Quintana Roo, followed by attempts to investigate the spatial and temporal distribution of physicochemical parameters to identify to identify places with the best quality for drinking consume within the study area. This goal has been achieved with the combined use of the Water Quality Index (WQI) and a geographical information system (GIS). The analyzed data correspond to the rainy seasons of 2002 and 2012. Physico-chemical parameters analyzed were pH; temperature (T °); total dissolved solids (TDS); total hardness; sodium (Na+); sulfate (SO42-); chlorides (Cl-), and nitrate (NO;). Descriptive statistics and maps of spatiotemporal distribution and ICA were used in the interpretation of the results. The results denoted conditions of spatial heterogeneity of the medium aquifer, due to processes such as mineral dissolution of carbonate rocks, dolomites and evaporates, the mixing of fresh-salt water and possible anthropogenic pollution, mainly by domestic sewage and fertilizer use. The chemical constituents that exceeded the allowable limit of NOM-127-SSA1-1994 were STD (22% in 2002, and 42% in 2012); total hardness (60%); Na+ (9.8%); Cl-(9.9%), and NO; (3%, 2012). The ICA showed that the chemical quality of groundwater for human consumption is acceptable to most of the sites studied. | Resumen: Este estudio se llevó a cabo con la finalidad de conocer el estado de la calidad del agua subterránea del acuífero sur de Quintana Roo, seguido de intentos por investigar la distribución espacial y temporal de los parámetros fisicoquímicos para identificar las zonas con mejor potencial aptas para consumo humano. Para este propósito se aplicaron en conjunto el índice de calidad del agua (ICA) y los sistemas de información geográfica (SIG). Los datos estudiados corresponden a las temporadas de lluvias de los años 2002 y 2012. Los parámetros fisicoquímicos analizados fueron pH, temperatura (T °), sólidos totales disueltos (SDT), dureza total, sodio (Na+1), sulfatos (SO42-), cloruros (Cl-) y nitratos (NO3-). En la interpretación de los resultados se emplearon estadísticos descriptivos y mapas de distribución espacio-temporal de concentraciones, así como el valor del ICA. Los resultados denotaron condiciones de heterogeneidad espacial en las concentraciones de los iones analizados a través del medio acuífero, debido a la propia geología del lugar; procesos, como la disolución de minerales de rocas carbonatadas, dolomías y evaporitas; mezcla de agua dulce-marina y una posible contaminación antropogénica, principalmente por aguas residuales domésticas y el uso de fertilizantes. Los constituyentes químicos que excedieron el límite permisible de la NOM-127-SSA1-1994 fueron: STD (22% en 2002, y 42% en 2012); dureza total (60%); Na+ (9.8%); Cl- (9.9%), y NO3- (3%, 2012). El ICA demostró que la calidad química del agua subterránea para consumo humano es aceptable para la mayoría de los sitios estudiados.
Show more [+] Less [-]Calidad del agua subterránea: acuífero sur de Quintana Roo, México Full text
2016
Joan Alberto Sánchez | Teresa Álvarez | Julia Guadalupe Pacheco | Laura Carrillo | Roger Amílcar González
Este estudio se llevó a cabo con la finalidad de conocer el estado de la calidad del agua subterránea del acuífero sur de Quintana Roo, seguido de intentos por investigar la distribución espacial y temporal de los parámetros fisicoquímicos para identificar las zonas con mejor potencial aptas para consumo humano. Para este propósito se aplicaron en conjunto el índice de calidad del agua (ICA) y los sistemas de información geográfica (SIG). Los datos estudiados corresponden a las temporadas de lluvias de los años 2002 y 2012. Los parámetros fisicoquímicos analizados fueron pH, temperatura (T °), sólidos totales disueltos (SDT), dureza total, sodio (Na+1), sulfatos (SO4 2-), cloruros (Cl-) y nitratos (NO3 -). En la interpretación de los resultados se emplearon estadísticos descriptivos y mapas de distribución espaciotemporal de concentraciones, así como el valor del ICA. Los resultados denotaron condiciones de heterogeneidad espacial en las concentraciones de los iones analizados a través del medio acuífero, debido a la propia geología del lugar; procesos, como la disolución de minerales de rocas carbonatadas, dolomías y evaporitas; mezcla de agua dulce-marina y una posible contaminación antropogénica, principalmente por aguas residuales domésticas y el uso de fertilizantes. Los constituyentes químicos que excedieron el límite permisible de la NOM-127-SSA1-1994 fueron: STD (22% en 2002, y 42% en 2012); dureza total (60%); Na+ (9.8%); Cl- (9.9%), y NO3 - (3%, 2012). El ICA demostró que la calidad química del agua subterránea para consumo humano es aceptable para la mayoría de los sitios estudiados.
Show more [+] Less [-]Gestión eficiente del agua con los contadores ultrasónicos inteligentes YZATEC Full text
2016
Gonçalves de Miranda, Victor | Calle, Alberto
Pasado y presente de los viajes del agua a Lorca Full text
2016
Trapote, Arturo | Jover-Smet, Margarita | Universidad de Alicante. Departamento de Ingeniería Civil | Recursos Hídricos y Desarrollo Sostenible
Caracterização experimental de um sistema de bombeamento de água fotovoltaico Full text
2016
Coutinho, Fábio A. B. | Tiba, Chigueru | Melo, Rinaldo O.
Este trabalho mostra a caracterização de sistema bombeamento de água fotovoltaico, realizada a partir de uma bancada de teste devidamente calibrada, e que permite simulações de diversas altura de recalque. Os dados experimentais foram modelados para permitir a estimativa da vazão do SBFV instalados em outros locais quaisquer. Foram calculados as eficiências dos subsistemas e do sistema como todo e avaliado também o efeito de liga/desliga do motor causado pela intermitência solar e temperatura. As modelagens foram feitas em escala de minuto e também horária. As eficiências globais obtidas estão consistentes com as características do equipamento utilizados. | Tema 2: Energía solar, aplicaciones agrícolas e industriales. | Facultad de Arquitectura y Urbanismo
Show more [+] Less [-]Pre-diseño de la planta potabilizadora de agua para el municipio de Pasca, Cundinamarca | Pre-design of the water treatment plant for the municipality of Pasca, Cundinamarca Full text
2016
Andrade Velásquez, Lina María | Castañeda Velásquez, Kristian Felipe
El propósito de este proyecto fue hacer el pre-diseño de una infraestructura necesaria para el suministro de agua potable en el casco urbano del Municipio de Pasca Cundinamarca, para una vida útil de 20 años, realizando una investigación de enfoque mixto y longitudinal, lo cual nos permitirá identificar las posibles soluciones basándonos en la recolección y análisis de datos cuantitativos y cualitativos, de alcance exploratorio, debido a que nuestro tema de investigación tiene pocos antecedentes. La primera parte del proyecto consistió en hacer un diagnóstico de las condiciones actuales del abastecimiento de agua potable a la población teniendo en cuenta la oferta, demanda y calidad del agua del afluente. Para determinar estas variables se hizo la proyección de la población para el año 2036, y así definir el nivel de complejidad y dotación neta del sistema de potabilización. Al analizar estos datos obtuvimos el caudal de diseño para una vida útil de 20 años. Posteriormente se evaluó el método de tratamiento más efectivo para potabilizar el agua, teniendo en cuenta variables como parámetros de calidad del agua y la normatividad vigente (resolución 2115 de 2007). Finalmente se hizo un presupuesto para determinar los costos preliminares del proyecto. Teniendo en cuenta los resultados obtenidos durante la investigación se puede concluir que es necesario realizar un nuevo diseño, debido a que en el actual sistema existen falencias en cuanto a capacidad de las estructuras y calidad del agua. | Ingeniero Ambiental | Pregrado | The purpose of this project was to make the pre-design of an infrastructure necessary for the supply of drinking water in the urban area of the Municipality of Pasca Cundinamarca, for a useful life of 20 years, conducting a mixed and longitudinal research approach, which will allow us to identify possible solutions based on the collection and analysis of quantitative and qualitative data, exploratory in scope, because our research topic has little background. The first part of the project consisted in making a diagnosis of the current conditions of drinking water supply to the population, taking into account the supply, demand and quality of the affluent water. To determine these variables, a population projection was made for the year 2036, in order to define the level of complexity and net supply of the drinking water treatment system. By analyzing these data we obtained the design flow for a useful life of 20 years. We then evaluated the most effective treatment method to make the water potable, taking into account variables such as water quality parameters and current regulations (Resolution 2115 of 2007). Finally, a budget was prepared to determine the preliminary costs of the project. Taking into account the results obtained during the research, it can be concluded that a new design is necessary because the current system has shortcomings in terms of structure capacity and water quality.
Show more [+] Less [-]