Refine search
Results 271-280 of 864
Estabilidade temporal do armazenamento de água em solo irrigado no Submédio São Francisco. Full text
2011
NASCIMENTO, P. dos S. | BASSOI, L. H. | SILVA, J. A.
Atividade de Enzimas antioxidantes em plântulas de algodoeiro herbáceo irrigada com água salina. Full text
2011
DUTRA, A. F. | ARAÚJO, J. dos S. S. | DANTAS, F. V. | FIGUEIREDO, L. F. de | ROCHA, M. do S. | BELTRAO, N. E. de M. | MELO, A. S. de
Estudio experimental de la eficiencia de mezcla en depósitos de abastecimiento de agua Full text
2011
Mujal i Colilles, Anna(Universitat Politecnica de Catalunya Grupo de Investigación en Transporte de Sedimentos) | Bateman-Pinzón, Alien(Universitat Politecnica de Catalunya Grupo de Investigación en Transporte de Sedimentos) | de Medina-Iglesias, Vicente(Universitat Politecnica de Catalunya Grupo de Investigación en Transporte de Sedimentos)
El fenómeno de la mezcla en depósitos de abastecimiento de agua tiene un efecto directo en la calidad del líquido saliente -por la creación de zonas de mezcla pobre y la estratificación-, que puede tener efectos negativos en la salud pública. El diseño de un depósito de abastecimiento debe considerar las condiciones de entrada y salida, así como su orientación, en caída libre o jet, para prevenir la formación de esas zonas. En este artículo se presentan los experimentos realizados en un modelo físico a escala reducida, considerando tres entradas diferentes (una por tubería y dos en caída libre), fijándose como objetivo decidir cuál de estas entradas consigue la mejor eficiencia de la mezcla. Además, se han estudiado los efectos que pueden producir las columnas que sostienen el techo del depósito sobre la eficiencia de la mezcla. Se ha realizado un tratamiento digital de las imágenes, con resultados de tipo cualitativo, que muestran que el flujo que sale por la tubería consigue una eficiencia mayor que el que se produce por las caídas libres tanto en modelo como en prototipo, debido al momentum horizontal que la primera de ellas imprime al flujo. Es importante destacar que el tiempo para mezclar el volumen almacenado depende de la distancia entre la entrada y la pared opuesta, así como de su orientación. En términos de las columnas, despreciando los efectos viscosos de escala y teniendo en cuenta todo el depósito, las columnas tienen un efecto negativo en la eficiencia de la mezcla, a pesar de dividir el flujo creando zonas de turbulencia local, ya que absorben energía del flujo y deterioran la velocidad de la mezcla en general. | The phenomenon of mixing in drinking water storage tanks and reservoirs has a direct effect on the quality of outgoing water due to the creation of poor mixing zones and volume stratification, which can produce negative effects on public health. The design of a storage tank must consider the conditions of the inlets and outlets, as well as their orientation (vertical or horizontal) to prevent the formation of these zones. This article presents experiments done at a reduced-scale physical model with three different inlets (a pipe and two waterfalls) in order to determine which of these inlets achieved the best mixing efficiency. Moreover, the effects on mixing efficiency by columns that support the roof of the tank were studied. A digital image technique was conducted with qualitative results that show that the flow leaving through a pipe obtains better efficiency than that of waterfalls, in both the model and the prototype, because of the horizontal momentum that the former exerts on the flow. It is important to note that the time taken to mix the stored volume depends on the distance between the inlet and the opposite wall, as well as its orientation. In terms of columns, neglecting the viscous scale effects and taking into account the whole tank, the columns have a negative effect on mixing efficiency, even though they divide the flow and create zones of local turbulence since they absorb energy from the flow and generally decrease the mixing speed.
Show more [+] Less [-]Emergência de plântulas de moranga em função da salinidade na água de irrigação. Full text
2011
LOPES, C. C. S. | SATURNINO, D. L. | SANTOS, E. E. F. | SANTOS, N. T. dos | SANTOS, C. A. F.
Proposição e avaliação de tecnologias para sistemas de aproveitamento de água da chuva Full text
2011
Lisboa, Marina Boldo | Lisboa, Henrique de Melo | Andrade, Márcio Antonio Nogueira | Universidade Federal de Santa Catarina
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2011 | No contexto da crescente pressão exercida sobre os recursos hídricos, que traz conseqüências tanto em relação aos aspectos quantitativos quanto qualitativos, o desenvolvimento de tecnologias apropriadas para sistemas de aproveitamento de água da chuva surge como uma alternativa promissora. Este trabalho tem como principal objetivo propor e avaliar tecnologias inovadoras para sistemas de aproveitamento de água da chuva, com enfoque no reservatório de armazenamento e nos dispositivos de descarte de sólidos e desvio dos primeiros escoamentos. No desenvolvimento das tecnologias aqui propostas, são apresentados três reservatórios com placas de ardósia, de 50, 80 e 250 m3, e um reservatório de chapas de aço galvanizado de 200 m3. Os dois primeiros foram executados em escolas públicas (sistemas piloto S1 e S2) e armazenam água da chuva para fins não-potáveis. Os outros dois foram construídos em instalações suinícolas e armazenam água da chuva para dessedentação animal e higienização das instalações (sistemas piloto S3 e S4). Após a execução dos sistemas piloto, foi calculada a eficiência dos mesmos. Paralelamente, foram feitas análises físico-químicas e bacteriológicas da água da chuva em diversos pontos dos sistemas piloto a fim de verificar sua qualidade ao longo do percurso no sistema, com enfoque na qualidade da água armazenada nos reservatórios. Nessa perspectiva, realizou-se um ensaio de potabilidade com o objetivo de verificar se os materiais utilizados em contato com a água armazenada nos reservatórios comprometem a potabilidade da água. Com os resultados de qualidade de água de chuva, foi possível calcular a eficiência dos conjuntos de dispositivos desenvolvidos e utilizados neste trabalho para tratamento físico da água da chuva. Por fim, foi realizada uma análise comparativa de custos entre os reservatórios de ardósia, os reservatórios de chapas de aço galvanizado e outros tipos de reservatórios comumente encontrados na região de estudo. Também foram verificados os custos dos dispositivos de descarte de sólidos e desvio dos primeiros escoamentos aqui desenvolvidos e propostos. Observando os resultados obtidos no cálculo da eficiência dos sistemas piloto, constatou-se que os sistemas piloto S1 e S2 atendem a 100% das demandas de água da chuva, respectivamente. Já os sistemas piloto S3 e S4 atendem a 41 e 40% das demandas, respectivamente. Na etapa de monitoramento da qualidade da água da chuva, pode-se concluir que a água armazenada nos reservatórios é de excelente qualidade. A grande maioria dos parâmetros estava de acordo com os padrões de potabilidade da Portaria no 518 do MS e observaram as condições ou padrões para as águas de classe 3 da Resolução CONAMA 357. Em alguns casos, somente o pH e/ou o teor de coliformes totais estavam fora dos padrões. A água da chuva, após passar pelo processo de desinfecção, se apresentou com melhor qualidade que as águas superficiais também fornecidas aos animais. Os resultados também comprovam que a água armazenada nos reservatórios, sem desinfecção, também se apresentou com melhor qualidade que as águas superficiais, para praticamente todos os parâmetros. O ensaio de potabilidade mostrou que a grande maioria dos elementos verificados se apresentou bem abaixo dos valores máximos permitidos pela Portaria no 518, do MS. Dois parâmetros, o ferro e o alumínio, apresentaram valores superiores ao máximo permitido pela Portaria. Porém, seus respectivos brancos também ficaram acima do máximo permitido, com exceção de dois dias de coleta, para o ferro. Isso significa que o problema pode não estar relacionado com os materiais imersos na água, e sim com o próprio branco. Apesar dos valores mais elevados destes dois elementos, verificou-se que a ardósia e a chapa metálica, em contato com a água, não comprometem sua qualidade. Os conjuntos de dispositivos de tratamento físico instalados neste trabalho apresentaram boa eficiência de remoção, todos acima de 50%. O método construtivo do reservatório de ardósia possibilitou a execução do mesmo com facilidade e rapidez, bom desempenho estrutural, e baixo custo de execução. O reservatório de aço é também uma boa opção devido à disponibilidade de empresas capacitadas, que trabalham com materiais similares, na execução de silos metálicos na região. Este reservatório apresentou maior facilidade e rapidez na execução, embora tenha apresentado um custo mais elevado em comparação ao reservatório de ardósia. Os dispositivos de descarte de sólidos e dispositivos de desvio dos primeiros escoamentos, desenvolvidos neste trabalho, e portanto, inovadores, também apresentaram baixo custo de execução, viabilidade técnica e ambiental | In the context of the increasing pressure on water resources, bringing consequences both in relation to qualitative and quantitative aspects, the development of appropriate technologies for rainwater harvesting systems emerges as a promising alternative. This work aims to propose and evaluate innovative technologies to rainwater harvesting systems, focusing on storage tank and on devices for solid disposal and first flush diverter. In the development of the technologies proposed, three slate tanks of 50, 80 and 250 m3 and one galvanized steel tank of 200 m3 are presented here. The first two were executed in public schools and they store rainwater to non-potable purposes (pilot systems S1 and S2). The other two were built in pig installations and they store rainwater to livestock drinking and sanitation farms (pilot systems S3 and S4). After the execution of the pilot systems, the efficiency of them was calculated. Parallel, physical-chemical and bacteriological analysis were made of rainwater at various points of pilot systems in order to verify the water quality along the system, with a focus on the quality of stored water in tanks. From this perspective, a potability test was realized in order to ascertain whether the materials used in contact with stored rainwater in tanks commit the drinking water. The efficiency of the sets of devices developed and used in this work to physical treatment of rainwater was evaluated. With the results of rainwater quality, it was possible to calculate the efficiency of the sets of devices developed and used in this work for rainwater physical treatment. Ultimately, a comparative analysis of costs between slate tanks, galvanized steel tanks and other types of tanks commonly found in the area of study was realized. The costs of devices for solid disposal and first flush diverter here proposed and developed were also verified. Observing the results obtained in calculating the efficiency of pilot systems, it was found that the pilot systems S1 and S2 meet 100% of rainwater demands, respectively. Already the pilot systems S3 and S4 meet 41 and 40% of demand, respectively. In the step of monitoring the rainwater quality, it can be concluded that the stored water in tanks has excellent quality. Most of parameters was in accordance with the standards of potability of Ordinance 518 of of Ministry of Health and observed the conditions or standards for Class 3 waters of CONAMA Resolution 357. In some cases, only the pH and / or the content of total coliforms were not in accordance with the standard. The rainwater, after passing through the disinfection process, performed with better quality than surface water also supplied to the animals. The results also prove that the stored water in reservoirs, without disinfection, also performed with better quality than surface water, for almost all parameters. The potability test showed that the vast majority of items checked performed below the maximum allowed by Ordinance 518. Two parameters, iron and aluminum, had values above the maximum allowed by Ordinance. However, in these days its respective whites had also been above of the allowed maximum, with exception of two days of collection, for the iron. This means that the problem may not be related to the materials immersed in water, but with the control sample. Despite the higher values of these two elements, it was found that slate and metal plate in contact with water, do not compromise quality. The sets of physical treatment devices installed in this work showed good removal efficiency, all above 50%. The constructive method of slate tank allowed the execution with ease and speed, good structural performance, and low cost of implementation. The steel tank is also a good option due to the availability of qualified companies who work with similar materials, in the performance of metal silos in the region. This reservoir has greater ease and speed of execution, although he has presented a higher cost in comparison to slate tank. Alternative devices were also developed for solid disposal and diversion devices of the first flush, which have provided low cost of implementation. The steel tank is also a good option because of the wide range of material in the region, to the ease and speed of execution, even showing a higher cost in comparison to slate tank. The devices for solid disposal and first flush diverter developed in this work, innovative, also had low cost of implementation, technical and environmental feasibility
Show more [+] Less [-]Comportamiento de medidores ante flujo de agua con sedimentos: diseño experimental y pruebas Full text
2011
Isaac Bonola Alonso | Edmundo Pedroza González | Alfredo Botello Hernández | Alberto Castro Salazar
En México, una muy importante proporción del agua usada para riego se extrae del subsuelo por medio de pozos profundos. La medición del agua así extraída se realiza frecuentemente con medidores que tienen algunos de sus componentes en contacto directo con el flujo, y cuando el agua contiene sedimento, dichos medidores presentan mal funcionamiento y no se tiene certeza sobre cuáles son las partes que fallan ni cómo. Un comentario común es que las partes móviles, como propelas y turbinas, se desgastan por la fricción de las partículas sólidas; pero no se encontró evidencia de tal afirmación. Para tener un mejor conocimiento del proceso de falla, se diseñó y construyó un banco de pruebas, en el que se colocaron medidores bajo condiciones de flujo con sedimentos. En este artículo se presentan las características del banco de pruebas, las diferentes etapas de su construcción, los detalles del programa experimental y los resultados. Lo más notorio fue que los componentes más dañados de los medidores, contra la opinión más aceptada, no son las partes móviles, sino los apoyos y rodamientos.
Show more [+] Less [-]Novas metodologias para coleta e manutenção de amostras de água para análises microbiológicas Full text
2011
Yadyr Augusto Figueiredo Filho | Sidneide Manfredini | Alberto Pacheco
Durante os trabalhos de pesquisa de contaminação de solo e águas subterrâneas por sepultamento de cadáveres, vísceras e partes de animais no solo, realizado no município de Pirassununga (SP), pesquisadores do Instituto de Geociências e do Departamento de Geografia da Universidade de São Paulo, desenvolveram novas metodologias de coleta, manutenção e transporte de amostras de água para análise de parâmetros microbiológicos. As novas metodologias foram desenvolvidas para investigação dos contaminantes microbiológicos pesquisados a partir de parâmetros estabelecidos pela MS 518/2004, CETESB e outros específicos de contaminação animal, estabelecidos a partir de trabalhos anteriores, que levantam provável fauna específica oriunda de cadáveres de animais, e a partir da “insuficiência” apresentada pelas metodologias tradicionais (e consagradas) indicadas pela Associação Brasileira de Normas Técnicas (ABNT), Companhia de Tecnologia de Saneamento Ambiental – CETESB e Standard Methods for Examination of Water and Wastewater (American Public Health Association – APHA, 2005).
Show more [+] Less [-]UMA GESTÃO PARTICIPATIVA NO LAGO JANAUACÁ – AM – BR – USO DA ÁGUA PARA AGRICULTURA Full text
2011
Maria Helena Carvalho Mourão | Manuel de Jesus Masulo da Cruz
Os impactos do desenvolvimento econômico sobre o ambiente natural vêm se intensificando. Estão em jogo os ecossistemas que sustentam todas as dinâmicas da humanidade. Torna-se fundamental a implantação de políticas públicas que permitam um crescimento econômico dentro dos princípios de desenvolvimento sustentável, de preservação da natureza e do equilíbrio dos ecossistemas, e maior igualdade social, com a melhoria da qualidade de vida de todos. Considerando essas questões relativas aos recursos hídricos e a constatação de sua essencialidade, o presente artigo tem o objetivo de discutir os principais pontos que norteiam a questão da gestão das águas no Lago Janauacá, conforme seus modelos e possíveis aplicações, analisando sua consistência e distanciamentos das demandas da sociedade, e de sua efetiva implantação. Não há aqui o interesse em quantificar a análise, mas sim o de discorrer sobre os argumentos que incentivam as sociedades a desenvolver formas de gerenciar os recursos hídricos. O foco compreende princípios, critérios e objetivos da Política Nacional de Recursos Hídricos e a necessidade de sua adequação para a implantação de instrumentos como o Comitê de bacias hidrográficas, que orientarão as ações de um planejamento estratégico para uma gestão integrada.
Show more [+] Less [-]Influência da concentração de extratos hidrofóbicos na repelência à água em solos arenosos Full text
2011
Yorleni Chang Cambronero | Claudia Maria Branco de Freitas Maia | Renato Antônio Dedecek | Fabrício Augusto Hansel
A repelência à água é estudada em vários solos do mundo, sendo os casos mais extremos encontrados em solos arenosos. Acredita-se que a repelência à água seja causada pelo recobrimento das partículas do solo por compostos hidrofóbicos derivados da decomposição de plantas. Este trabalho avaliou a influência da concentração de extratos hidrofóbicos de um Neossolo sob plantio de Pinus taeda, na repelência à água em amostras de um solo arenoso preparado em laboratório, com diferentes teores de matéria orgânica. Os extratos hidrofóbicos do solo original foram extraídos com clorofórmio:acetona, seguido de isopropanol:amônia. Os tratamentos constaram de mistura de areia com sete níveis de matéria orgânica (0%; 3%; 6,5%; 6,5% + 10% de ácido húmico (AH); 6,5% + 30% de AH; 6,5% + 50% de AH; e 10%), aos quais foram aplicadas três concentrações de extrato hidrofóbico (CEH). As amostras foram secas a diversas temperaturas antes dos testes de repelência. As CEHs induziram à repelência à água nos tratamentos, em diferentes intensidades, porém estes valores foram inferiores aos encontrados no solo original. Os tratamentos com CEH de 2,88 g kg-1 tiveram os maiores tempos de repelência. doi: 10.4336/2011.pfb.31.65.01
Show more [+] Less [-]Teor de óleo no pinhão manso em função de lâminas de água residuária Full text
2011
Antonio Evami Cavalcante Sousa | Hans Raj Gheyi | Frederico Antonio Loureiro Soares | Everaldo Paulo de Medeiros | Elka Costa Santos Nascimento
O objetivo deste trabalho foi estudar a influência de lâminas de irrigação com água residuária e duas doses de fósforo sobre a produtividade e o teor de óleo de sementes de pinhão manso. Foi utilizado o delineamento em blocos ao acaso, em esquema fatorial 5x2, com quatro repetições com uma planta por parcela. Os tratamentos foram compostos pela combinação de cinco níveis de reposição hídrica (0,25, 0,50, 0,75, 1,00 e 1,25 do consumo das plantas) e duas doses de P2O5 (135 e 200 g por planta) por ano. A produtividade e o teor de óleo das sementes de pinhão manso foram afetados positiva e significativamente pelo nível de reposição hídrica, enquanto as doses de fósforo não tiveram nenhuma influência.
Show more [+] Less [-]