Determining the degree of fireretardancy of plywood with thermogravimetry. Part 1: beech plywood
2007
Gavrilovic-Grmusa, I.,Univerzitet u Beogradu, Beograd (Serbia). Sumarski fakultet | Miljkovic, J.,Univerzitet u Beogradu, Beograd (Serbia). Sumarski fakultet | Djiporovic-Momcilovic, M.,Univerzitet u Beogradu, Beograd (Serbia). Sumarski fakultet | Kacarevic-Popovic, Z.,Univerzitet u Beogradu, Beograd (Serbia). Sumarski fakultet
The basic motive of this work is the ever more pronounced need for fire-resistant plywood. In this work, beech veneers have been impregnated with solutions of chosen fire retardants, which are diammonium phosphate, monoammonium phosphate, sodium acetate, water glass, sodium tetraborate and boric acid. The determine the preliminary level of fire retardancy achieved in veneers before manufacturing of finished plywood, thermogravimetric (TG) and derivative thermogravimetric (DTG) methods are used. TG and DTG analyses of treated and untreated wood, as well as of fire retardants alone, were performed in a Perkin-Elmer TGS-2 thermogravimetric equipment. Fire resistance of plywood was tested in accordance with standard test for resistance to the effects of fire and the most efficient fire retardants, monoammonium phosphate and sodium tetraborate, had the same results as TG/DTG analyses, which points out the validity of TG methods in predicting success of fire retardants in future products.
Mostrar más [+] Menos [-]Palabras clave de AGROVOC
Información bibliográfica
Este registro bibliográfico ha sido proporcionado por Matica Srpska Library