Hydraulic Retention Time Influence on Improving Flocculation in the Activated Sludge Processes Through Polyelectrolytes
2017
Almeida-Naranjo, Cristina E. | Espinoza-Montero, Patricio J. | Muñoz-Rodríguez, Marcelo I. | Villamar-Ayala, Cristina A.
Hydraulic retention time (HRT) influence improving sludge flocculation with adding the polyelectrolytes (non-ionic, anionic, and cationic) was studied on an activated sludge (AS) system fed with synthetic domestic wastewater (SDW), dairy industry wastewater (DIW), and caramel industry wastewater (CIW). The sludge volumetric index, food/microorganism ratio (F/M), and mixed liquor volatile suspended solids at different HRTs (6, 8 and 10 h) were monitored on an experimental model. Results showed that both SDW and IW had the best sludge flocculation conditions at 8 h and 100 mL of non-ionic polyelectrolyte (0.2 mg L⁻¹). In addition, this phenomenon reached the organic matter removal efficiencies of 95.9, 95.7, and 94.2% for SDW, DIW, and CIW, respectively. Therefore, optimum HRT increased the organic matter removal efficiencies by 10%, sludge concentration by 37% (22–55%), and F/M ratio by 70%. Moreover, the polyelectrolytes used in AS improved the sludge flocculation by 2.9 times.
Mostrar más [+] Menos [-]Palabras clave de AGROVOC
Información bibliográfica
Este registro bibliográfico ha sido proporcionado por National Agricultural Library