Estimation of Annual Effective Dose of 222 Rn and 220 Rn in indoor Air of Rohilkhand region, Uttar Pradesh state, India
2018
Rastogi, N. | Singh, I. | Goswami, V.
The annual exposure to indoor radon and thoron imparts a major contribution to inhalation doses received by the public. In this study, we report results of time integrated passive of indoor radon and thoron concentrations that were carried out in Rohilkhand region with health risk to the dwellers in the region. In present study, Solid State Nuclear Track Detectors (SSNTDS ) based twin chamber dosimeter with LR-115 track detector were used for estimating Radon (222Rn) and Thoron (220Rn) gas concentration levels in the dwellings of Moradabad city. The average Radon and thoron concentration levels in the studied dwellings were found to vary from 13.5 to 21.8 Bq m-3 and thoron concentrations is found to vary from 11.7 to 19.5 Bqm-3 and its corresponding geometric mean of equilibrium-equivalent 222Rn and 220Rn concentration were found 7.07 to 1.7 Bqm-3 . The total annual effective dose due to the exposure to radon and thoron was found to vary from3.7 to 6.2 mSv/y whereas from thoron found to vary from 0.3 to 0.61 mSv/y.
Mostrar más [+] Menos [-]Palabras clave de AGROVOC
Información bibliográfica
Este registro bibliográfico ha sido proporcionado por University of Tehran