Early pregnancy diagnosis in goats by determination of pregnancy-associated glycoprotein concentrations in plasma samples.
1999
González, F | Sulon, J | Garbayo, J M | Batista, M | Cabrera, F | Calero, P | Gracia, A | Beckers, Jean-François
Inglés. peer reviewed
Mostrar más [+] Menos [-]Inglés. Different RIA systems available for measuring the concentrations of pregnancy-associated glycoproteins (PAGs) in dairy goats were compared in order to evaluate their accuracy in early pregnancy diagnosis. Plasma concentrations of PAGs were determined by 3 heterologous RIA systems with a bovine PAG standard and tracer in combination with antisera anti-ovine PAG (RIA 1), anti-caprine PAG55 + 62 (RIA 2), anti-caprine PAG55 + 59 (RIA 3), and by 2 homologous RIA systems that employed caprine PAG55 + 62 and caprine PAG55 + 59 and their specific antisera (RIAs 4 and 5, respectively). In all of the RIAs, the mean concentrations of PAGs were significantly higher (P < 0.01) in pregnant than in nonpregnant goats from Day 21 onwards after breeding. On Day 21, the accuracy rates of early pregnancy diagnoses were 56% (RIA 1), 96% (RIA 2), 99% (RIA 3), 95% (RIA 4) and 90% (RIA 5), whereas on Day 28 these rates were > 99% for RIAs 2, 3, 4 and 5. The RIAs for PAGs depend on proteins from the placenta being present in maternal plasma and require only a single sample of blood, to distinguish pregnant goats from those that fail to return to estrus for other reasons. The homologous and semi-heterologous assays are highly accurate as early as Day 21 of pregnancy.
Mostrar más [+] Menos [-]Palabras clave de AGROVOC
Información bibliográfica
Este registro bibliográfico ha sido proporcionado por University of Liège