Refinar búsqueda
Resultados 101-110 de 507
Evaluation of granulocytic ehrlichiosis in dogs of Missouri, including serologic status to Ehrlichia canis, Ehrlichia equi, and Borrelia burgdorferi
1992
Stockham, S.L. | Schmidt, D.A. | Curtis, K.S. | Schauf, B.G. | Tyler, J.W. | Simpson, S.T.
Canine granulocytic ehrlichiosis was diagnosed in 37 dogs by finding ehrlichial morulae in 0.1 to 26.2% of their blood neutrophils and eosinophils. All 37 dogs had clinical signs of arthritis or muscular stiffness. Titer to Ehrlichia canis was determined in sera from 31 of the 37 dogs; 25 dogs had titer ranging from 1:20 to 1:5,120. In the other 6 dogs, titer to E canis was < 1:10. The most common hematologic abnormality in these dogs, other than rickettsiemia, was thrombocytopenia. Granulocytes infected with ehrlichial organisms were not found in another 10 dogs that had clinical signs of arthritis or muscular stiffness. Of these 10 dogs, 3 had titer to E canis ranging from 1:40 to 1:320. Titer in the other 7 dogs was < 1:10. Ehrlichial morulae were not found in the granulocytes of 18 healthy dogs. Of these 18 dogs, 9 had titer to E canis ranging from 1:20 to 1:5,120. Titer in the other 9 dogs was < 1:10. Titer to Borrelia burgdorferi was determined in dogs with granulocytic ehrlichiosis, arthritic dogs without detected rickettsiemia, and in healthy dogs. Low titer determined by 2 laboratories was considered to be nonspecific reaction in all 3 groups of dogs and, thus, did not indicate that the arthritic disorders were attributable to canine borreliosis.
Mostrar más [+] Menos [-]Polypeptides associated with Pasteurella multocida infection in rabbits
1992
Zimmerman, T.E. | Deeb, B.J. | DiGiacomo, R.F.
Polypeptides from whole cell preparations of Pasteurella multocida serotypes A:12 and A:3 were separated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis and transferred to nitrocellulose paper. Antigens were detected by immunoblot analysis, using sera from 3 groups of rabbits. Sera were obtained from rabbits inoculated intranasally with P multocida serotype A:12 or A:3, from rabbits maintained in a rabbitry with enzootic P multocida A:12 infection, and from rabbits maintained in a rabbitry with enzootic P multocida A:3 infection. Immunoblot analyses of pre- and postinoculation sera from experimentally infected rabbits, using serotype A:12 antigen, revealed 3 polypeptides with approximate molecular mass of 28, 30, and 37 kDa that consistently detected antibodies after P multocida-induced infection. Sera from rabbits naturally infected with either serotype, tested against serotype A:12 and A:3 antigens, detected the same polypeptides in both serotypes. Thus, immunologic reactivity to these polypeptides may be useful for serologic detection of P multocida infection.
Mostrar más [+] Menos [-]Microvascular circulation of the descending colon in horses
1992
Dart, A.J. | Snyder, J.R. | Harmon, F.A.
The microvascular circulation of the descending colon was studied in 5 adult horses, using microangiography and light microscopy combined with gross studies and scanning electron microscopy of vascular replicas. After heparinization, horses were euthanatized, and 3 segments of the descending colon and its mesentery containing 1 vascular arcade were removed from each horse. The fecal bars were gently massaged from the lumen, and the blood was flushed free of the circulation with isotonic NaCl. In 5 segments, the vascular system was injected with a modified radiopaque medium and evaluated radiographically. Specimens examined radiographically also were prepared for histologic examination, using standard methods. Ten segments were injected with 1 of 2 types of plastics and studied grossly or by scanning electron microscopy. Arcuate arteries gave rise to a descending colonic rete that surrounded the vein and supplied numerous descending colonic lymph nodes. The rete also supplied the mesocolon and the descending colonic tissue. Short filamentous vessels arising from the rete directly penetrated the mesenteric tenia to supply an intermuscular plexus between the longitudinal and circular muscle layers of the muscularis externa. Larger vessels arising from either side of the rete divided into the long- and short-terminal arteries that supplied an extensive submucosal plexus, which was continuous around the circumference. The submucosal plexus supplied the mucosa, the tunica muscularis, and the serosa. Vessels running centrifugally from the submucosal plexus formed an intermuscular plexus between the longitudinal and circular muscle layers of the muscularis externa. The intermuscular plexus at the mesenteric angle also was supplied by vessels branching from the short-terminal arteries as they penetrated the muscularis externa. At the antimesenteric tenia, the submucosal plexus gave rise to larger vessels that formed a subserosal loop. From this loop, 5 vessels penetrated the longitudinal muscle layer to contribute to the intermuscular plexus. Vessels within the longitudinal and circular muscles of the muscularis externa ran parallel to the muscle fibers and, consequently, perpendicular to each other. Arteries supplying the mucosa penetrated the muscularis mucosa and branched into a capillary network at the base of the descending colonic glands. These capillary networks anastomosed with the networks around adjacent glands at the luminal surface, forming a honeycomb-like pattern. Drainage was facilitated by more sparsely distributed venules that united with venules from adjacent areas and descended to the submucosal plexus. These veins were characterized by regular, helical, smooth muscle constrictions.
Mostrar más [+] Menos [-]Detection of hemorrhagic septicemia virus of salmonid fishes by use of an enzyme-linked immunosorbent assay containing high sodium chloride concentration and two noncompetitive monoclonal antibodies against early viral nucleoproteins
1992
Sanz, F.A. | Coll, J.M.
Inclusion of high-ionic strength buffers helped us to develop a sandwich ELISA to detect hemorrhagic septicemia virus (HSV) in cell culture and infected trout tissue extracts. For maximal sensitivity of 0.1 to 0.2 ng/well/100 microliter or about 10 to 50 TCID50/well/100 microliter, trout extracts were diluted 1:1 and assayed for the earliest synthesized nucleoprotein N. Simultaneous binding of the N protein from HSV in the sample to the wells coated with monoclonal antibody (2D5 against the N protein) and to the peroxidase-labeled monoclonal antibody (2C9 against the N protein) proceeded during a 2-hour incubation at 20 to 22 C (room temperature). The response was linear between 6 to 60 ng/well of purified virus. Monoclonal antibodies used were noncompetitive with each other and reacted with F1, F2, 23.75, and 5 Spanish isolates of HSV, but not with infectious hematopoietic necrosis or infectious pancreatic necrosis viruses. Tissue specimens with low content of HSV virus may now be assayed directly without use of cell culture, rapidly, and with high precision, during the acute phase of the disease in salmonid fishes.
Mostrar más [+] Menos [-]Evaluation of an automated system for hemoglobin measurement in animals
1992
Callan, M.B. | Giger, U. | Oakley, D.A. | Scotti, M.V. | Shofer, F.S.
In veterinary medicine, PCV determined by centrifugation of blood in a microhematocrit tube is the most common clinical test used to initially assess and monitor anemic and polycythemic animals. In contrast, blood hemoglobin (Hb) concentration, rather than PCV, is generally determined in human patients. One automated system photometrically measures blood Hb concentration after conversion of Hb to azide methemoglobin without dilution and was found to be a simple and accurate instrument for use in human medicine. We evaluated the system for its accuracy in measuring blood Hb concentration in animals by comparing it with standard techniques and for its suitability in veterinary practice. Blood samples, anticoagulated with potassium EDTA, from 78 healthy animals (33 dogs, 17 cats, 13 horses, and 15 cows) and 58 dogs and 4 cats with various blood abnormalities (10 anemia, 11 polycythemia, 21 lipemia, 16 leukocytosis, and 6 icterus) were analyzed. In all species, blood Hb concentration of healthy animals determined by the system was comparable to that measured by standard cyanmethemoglobin methods (ie, an automated counter; rI = 0.987 to 0.998 and a hemoglobin kit, rI = 0.946 to 0.993). The aforementioned system also yielded similar values to those obtained by use of standard methods in anemic, polycythemic, and icteric dogs and cats. Moreover, the system reads the absorbance at 2 wavelengths to correct for turbidity, and therefore, accurately measured Hb concentration in blood samples with severe lipemia (triglycerides concentration > 500 mg/dl) and marked leukocytosis (> 50,000 WBC/microl), whereas other standard Hb techniques are known to give falsely high results. We conclude that the automated system compares favorably to standard methods, and is a simple and accurate instrument to quickly measure Hb concentration in animals.
Mostrar más [+] Menos [-]Effects of xylazine on airway function in ponies with recurrent airway obstruction
1992
Broadstone, R.V. | Gray, P.R. | Robinson, N.E. | Derksen, F.J.
The effect of IV administration of the alpha2-adrenoceptor agonist xylazine hydrochloride (0.5 mg/kg of body weight) was examined in ponies with recurrent obstructive pulmonary disease, commonly called heaves. Six ponies with the disease (principals) were studied during clinical remission and during an acute attack of airway obstruction precipitated by stabling and feeding of dusty hay. Six control ponies were also studied. In principal ponies with airway obstruction, xylazine administration significantly (P < 0.05) decreased pulmonary resistance and increased dynamic compliance, but did not affect PaO2 or PaCO2. The alpha 2-antagonist yohimbine blocked the pulmonary effects of xylazine. Administration of saline solution was without effect in both groups of ponies at all periods and xylazine did not have effect in controls or in principals in clinical remission.
Mostrar más [+] Menos [-]Evaluation of serum fructosamine concentration as an index of blood glucose control in cats with diabetes mellitus
1992
Kaneko, J.J. | Kawamoto, M. | Heusner, A.A. | Feldman, E.C. | Koizumi, I.
Fructosamine, a glycated serum protein, was evaluated as an index of glycemic control in normal and diabetic cats. Fructosamine was determined manually by use of a modification of an automated method. The within-run precision was 2.4 to 3.2%, and the day-to-day precision was 2.7 to 3.1%. Fructosamine was found to be stable in serum samples stored for 1 week at 4 degrees C and for 2 weeks at -20 degrees C. The reference range for serum fructosamine concentration in 31 clinically normal colony cats was 2.19 to 3.47 mmol/L (mean, 2.83 +/- 0.32 mmol/L). In 27 samples from 16 cats with poorly controlled diabetes mellitus, the range for fructosamine concentration was 3.04 to 8.83 mmol/L (mean, 5.93 +/- 1.35 mmol/L). Fructosamine concentration was directly and highly correlated to blood glucose concentration. Fructosamine concentration also remained high in consort with increased blood glucose concentration in cats with poorly controlled diabetes mellitus over extended periods. It is concluded that measurement of serum fructosamine concentration can be a valuable adjunct to blood glucose monitoring to evaluate glycemic control in diabetic cats. The question of whether fructosamine can replace glucose for monitoring control of diabetes mellitus requires further study.
Mostrar más [+] Menos [-]Prevalence of Haemophilus parasuis serovars among isolates from swine
1992
Rapp-Gabrielson, V.J. | Gabrielson, D.A.
Two hundred sixty Haemophilus spp isolates that had been obtained from the respiratory tract and other sites of swine were acquired from diagnostic laboratories, primarily in the United States and Canada. The majority of isolates (243/260) were biochemically characterized as H parasuis; however, a few isolates of taxa distinct from H parasuis (taxa "minor group," D, E, and F) were identified. Fourteen H parasuis serovars were identified, and of those previously described, the most prevalent were 5 (24.3% of isolates), 4 (16.1%), 2 (8.2%), and 7 (3.7%). Three new serovars that were also prevalent included ND4 (11.1%), ND3 (8.6%), and ND5 (6.6%). Serovars 1, 3, 6, C, D, and new serovars ND1 and ND2 were infrequently identified, and 15.2% of isolates were nontypeable. It was not uncommon to isolate multiple serovars from swine of the same herd or related herds. Distribution of serovars among isolates from the United States and Canada was generally similar; however, a higher prevalence of serovar 5 and a lower prevalence of serovars 2, ND3, and ND5 were evident in isolates from Canada. Comparison of isolates obtained from the respiratory tract of swine without polyserositis with those obtained from swine with polyserositis revealed an increased frequency of serovars 4 and 5, and a decreased frequency of serovar 2, among isolates from swine with polyserositis. However, all prevalent serovars were isolated from swine with polyserositis, and data were not indicative of an association between serovar, site of isolation, or pathogenic potential.
Mostrar más [+] Menos [-]Comparison of two catheter withdrawal speeds during simultaneous urethral pressure profilometry in anesthetized bitches
1992
Gregory, S.P. | Holt, P.E. | Parkinson, T.J.
Maximal urethral closure pressure, functional profile length, and number of respiratory peaks on the resting urethral pressure profile, expressed as a percentage of those occurring on the bladder pressure recording, were compared at catheter withdrawal speeds of 1 and 3 mm/s in 30 anesthetized bitches. Significant (P < 0.001) differences were found in maximal urethral closure pressure and percentage of transmission of respiratory peaks between the 2 speeds. Significant difference was not detected in functional pro-file length.
Mostrar más [+] Menos [-]Effect of short-term exposure of chickens to corticosterone on resistance to challenge exposure with Escherichia coli and antibody response to sheep erythrocytes
1992
Gross, W.B.
Chickens in a low-stress environment (heterophil/lymphocyte ratio 0.31) were given feed containing 30, 40, or 60 mg of corticosterone/kg of feed for 0.5 hour. Between 0.5 to 12 hours later, chickens were exposed to Escherichia coli via the air sac route. For each dose of corticosterone, there was an untreated control group that was exposed to E coli via the air sac route. The prevalence of pericarditis was reduced from 78 to 7% between 2 and 4 hours after exposure. Resistance was associated with heterophil/lymphocyte (H/L) ratios greater than 1.04. Peak H/L ratios correlated positively with amount of corticosterone in the feed. In one experiment, chickens were inoculated IV with sheep erythrocytes at various times after consumption of feed containing corticosterone. Suppression of antibody responsiveness was most pronounced 4 hours later. Antibody responsiveness correlated positively with lymphocyte numbers. Histologic examination of air sacs was made following euthanasia at various times after E coli exposure. Lesions observed in control chickens included: edema at 0.5 hour, beginning of heterophil infiltration at 1 hour, increased edema and heterophil infiltration at 2 hours, and severe edema and heterophil infiltration at 4 hours. Lesions were not observed in chickens that had been given feed containing 40 mg of corticosterone/kg of feed.
Mostrar más [+] Menos [-]