EVALUATION ROLE OF THE AUTOGENOUS PERITONEUM AS A SCAFFOLDS ON THE HEALING OF ACHILLES TENDONS IN DOGS Texto completo
2019
A H Allawi | L M Alkattan
The objective of the current study was to evaluate the healing of experimentally severed Achilles tendons of the dogs repaired by Kessler suture pattern alone or with autologous peritoneal scaffold. A total of twelve healthy, neurologically and orthopedically local breed dogs were used in this study, which were randomly allocated into two equal groups (6 of each). The 1st group as a control, while the 2nd as a treated group. In both groups the Achilles tendon of one hind limb was completely severed transversely, in 1st group the tendon was repaired by Kessler suture pattern using silk No.3, while in the 2nd group a combination of Kessler suture and autogenous peritoneal scaffold was applied to reinforce the tendon repair. The site of surgery was evaluated clinically, while gross and histological study was performed at 15, 30 and 60 days post-operative days. Results was revealed that autologous peritoneum graft has a remarkable effects on Achilles tendon healing represented by improving fibroblastic proliferation, reduce adhesion, increase tendon strength and improve tendon function when compared with the control group. We concluded that peritoneal graft application has valuable and beneficial effects on treatment of ruptured Achilles tendon in dogs when utilizing it in conjunction with the traditional procedures.
Mostrar más [+] Menos [-]In vitro evaluation of negative pressure generated during application of negative suction volumes by use of various syringes with and without thoracostomy tubes Texto completo
2019
Mezzles, Marguerite J. | Murray, Rebecca L. | Heiser, Brian P.
OBJECTIVE To determine the amount of negative pressure generated by syringes of various sizes with and without an attached thoracostomy tube and whether composition of thoracostomy tubes altered the negative pressure generated. SAMPLE Syringes ranging from 1 to 60 mL and 4 thoracostomy tubes of various compositions (1 red rubber catheter, 1 polyvinyl tube, and 2 silicone tubes). PROCEDURES A syringe or syringe with attached thoracostomy tube was connected to a pneumatic transducer. Each syringe was used to aspirate a volume of air 10 times. Negative pressure generated was measured and compared among the various syringe sizes and various thoracostomy tubes. RESULTS The negative pressure generated decreased as size of the syringe increased for a fixed volume across syringes. Addition of a thoracostomy tube further decreased the amount of negative pressure. The red rubber catheter resulted in the least amount of negative pressure, followed by the polyvinyl tube and then the silicone tubes. There was no significant difference in negative pressure between the 2 silicone tubes. The smallest amount of negative pressure generated was −74 to −83 mm Hg. CONCLUSIONS AND CLINICAL RELEVANCE Limited data are available on the negative pressure generated during intermittent evacuation of the thoracic cavity. For the present study, use of a syringe of ≥ 20 mL and application of 1 mL of negative suction volume resulted in in vitro pressures much more negative than the currently recommended pressure of −14.71 mm Hg for continuous suction. Additional in vitro or cadaveric studies are needed.
Mostrar más [+] Menos [-]Effect of orally administered melatonin on intraocular pressure of ophthalmologically normal dogs Texto completo
2019
Visser, Hannah E. | Dees, D Dustin | Millichamp, Nicholas J. | Vallone, Lucien V. | Scott, Erin M.
OBJECTIVE To determine the effect of orally administered melatonin on the intraocular pressure (IOP) of ophthalmologically normal dogs. ANIMALS 20 ophthalmologically normal dogs (40 eyes). PROCEDURES In a randomized crossover study, each dog received a 7-day regimen of melatonin (0.1 to 0.2 mg/kg, PO, q 12 h) and a placebo (150 mg of lactose powder in a capsule, PO, q 12 h), with a 7-day washout period between treatment regimens. Rebound tonometry was used to measure the IOP in both eyes of each dog 5 times at 2-hour intervals on days 0 (before administration of the first dose), 2, 4, and 7 (after administration of the last dose) of each treatment period. Repeated-measures ANOVA was used to evaluate the effects of treatment, day, and IOP measurement time within day on IOP. RESULTS Intraocular pressure was not significantly associated with treatment but was associated with day and the interaction between day and IOP measurement time within day. The mean ± SD IOP was 14.26 ± 2.95 and 14.34 ± 2.69 mm Hg for the melatonin and placebo regimens, respectively. Within each treatment period, the mean IOP tended to decrease from day 0 to 7 as well as within each day, which was attributed to the dogs becoming acclimated to the study protocol and natural diurnal variations in IOP. CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that oral administration of melatonin (0.1 to 0.2 mg/kg, q 12 h for 7 d) did not significantly affect the IOP of ophthalmologically normal dogs.
Mostrar más [+] Menos [-]Biomechanical comparison of a modified three-loop pulley technique and a three-level self-locking technique for repair of patellar tendon rupture in dogs Texto completo
2019
Soula, Mariajesus | Shmalberg, Justin W. | Johnson, Matthew D.
OBJECTIVE To compare use of a 3-level self-locking suture (3LSLS) technique with use of a previously described modified 3-loop pulley (M3LP) technique to repair rupture of the proximal aspect of patellar tendons in limbs from canine cadavers. SAMPLE Paired hind limbs of 6 adult mixed-breed dogs. PROCEDURES A limb from each pair was randomly assigned to be repaired by the 3LSLS technique or M3LP technique with size-2 ultrahigh-molecular-weight polyethylene and size-0 monofilament polypropylene suture, respectively. Limbs were prepared, and each patellar tendon was transected at a site chosen to simulate rupture at the proximal aspect. Tendons were repaired with the assigned techniques and mechanically tested with a biaxial servohydraulic test system; the clamp was distracted until the repair failed. Force at 1 -mm gap formation, 3-mm gap formation, and repair failure and gap size at failure were measured and compared between methods. Mode of failure was recorded. RESULTS There was no significant difference between methods for the force required to produce a 1 - or 3-mm gap in the repair. The 3LSLS technique required a significantly higher load for complete failure; gap formation immediately before failure was significantly greater for this method than for the M3LP technique. Four of 6 repairs with the M3LP technique and 0 of 6 repairs with the 3LSLS technique failed by suture breakage. CONCLUSIONS AND CLINICAL RELEVANCE The 3LSLS technique with size-2 ultrahigh-molecular-weight polyethylene suture was as effective at resistance to 1 - and 3-mm gap formation as the M3LP with size-0 monofilament polypropylene suture.
Mostrar más [+] Menos [-]Comparison of three walkway cover types for use during objective canine gait analysis with a pressure-sensitive walkway Texto completo
2019
Kieves, Nina R. | Hart, Juliette L. | Evans, Richard B. | Duerr, Felix M.
OBJECTIVE To compare the effects of 3 walkway cover types on temporospatial and ground reaction force measurements of dogs during gait analysis with a pressure-sensitive walkway (PSW). ANIMALS 35 client- and staff-owned dogs (25 nonlame and 10 lame). PROCEDURES In a crossover study design, all dogs were evaluated at a comfortable walk on a PSW to which 3 cover types (a 0.32-cm-thick corrugated vinyl mat or a 0.32- or 0.64-cm-thick polyvinyl chloride yoga mat) were applied in random order. Temporospatial and ground reaction force measurements were obtained and compared among cover types within the nonlame and lame dog groups. RESULTS Several variables, including maximum peak pressure, maximum force (absolute and normalized as a percentage of body weight), and vertical impulse (absolute and normalized) differed significantly in most comparisons among cover types for both nonlame and lame dogs. There was no significant difference in maximum force values between the 0.32-cm-thick corrugated vinyl and 0.64-cm-thick polyvinyl chloride cover types for both nonlame and lame dogs. CONCLUSIONS AND CLINICAL RELEVANCE To the authors’ knowledge, the cover type used during data collection with a PSW is rarely provided in published reports on this topic. The findings in this study suggested that to ensure that PSW data for dogs are collected in a standardized manner, the same cover type should be used during follow-up visits to evaluate clinical outcomes, for the duration of research studies, and at all locations for multi-institutional studies. The cover type should be specified in future PSW studies to allow direct comparisons of findings between studies.
Mostrar más [+] Menos [-]Effects of ventilation mode and blood flow on arterial oxygenation during pulse-delivered inhaled nitric oxide in anesthetized horses Texto completo
2019
Auckburally, Adam | Grubb, Tamara L. | Wiklund, Maja | Nyman, Gorel
OBJECTIVE To determine the impact of mechanical ventilation (MV) and perfusion conditions on the efficacy of pulse-delivered inhaled nitric oxide (PiNO) in anesthetized horses. ANIMALS 27 healthy adult horses. PROCEDURES Anesthetized horses were allocated into 4 groups: spontaneous breathing (SB) with low (< 70 mm Hg) mean arterial blood pressure (MAP; group SB-L; n = 7), SB with physiologically normal (≥ 70 mm Hg) MAP (group SB-N; 8), MV with low MAP (group MV-L; 6), and MV with physiologically normal MAP (group MV-N; 6). Dobutamine was used to maintain MAP > 70 mm Hg. Data were collected after a 60-minute equilibration period and at 15 and 30 minutes during PiNO administration. Variables included Pao2, arterial oxygen saturation and content, oxygen delivery, and physiologic dead space-to-tidal volume ratio. Data were analyzed with Shapiro-Wilk, Mann-Whitney U, and Friedman ANOVA tests. RESULTS Pao2, arterial oxygen saturation, arterial oxygen content, and oxygen delivery increased significantly with PiNO in the SB-L, SB-N, and MV-N groups; were significantly lower in group MV-L than in group MV-N; and were lower in MV-N than in both SB groups during PiNO. Physiologic dead space-to-tidal volume ratio was highest in the MV-L group. CONCLUSIONS AND CLINICAL RELEVANCE Pulmonary perfusion impacted PiNO efficacy during MV but not during SB. Use of PiNO failed to increase oxygenation in the MV-L group, likely because of profound ventilation-perfusion mismatching. During SB, PiNO improved oxygenation irrespective of the magnitude of blood flow, but hypoventilation and hypercarbia persisted. Use of PiNO was most effective in horses with adequate perfusion.
Mostrar más [+] Menos [-]Lactate and glucose thresholds and heart rate deflection points for Beagles during intense exercise Texto completo
2019
Restan, Alejandro Z. | Zacche, Evandro | Da Silva, Samara B. | Cerqueira, Juliana A. | Carfiofi, Aulus C. | Queiroz-Neto, Antonio | Camacho, Aparecido A. | Ferraz, Gulherme C.
OBJECTIVE To determine whether the lactate threshold of dogs could be determined by a visual method and to assess the extent of agreement and bias among treadmill velocities for the lactate threshold as determined by visual (LTv) and polynomial (LTp) methods, glucose threshold as determined by visual (GTv) and polynomial (GTp) methods, and heart rate deflection point (HRdp) as a method for estimating the aerobic capacity of dogs. ANIMALS 18 healthy adult Beagles. PROCEDURES Each dog underwent a standardized incremental treadmill exercise test once. The test ended when the dog began to show signs of fatigue. Plasma lactate and glucose concentrations and heart rate (HR) were plotted against exercise intensity (treadmill velocity) for the duration of the test, and the LTv, GTv, and HRdp were determined visually. The LTp and GTp were determined by means of a second-order polynomial function. One-way ANOVA, Pearson correlation, Bland-Altman analyses, and ordinary least products regression were used to assess the extent of agreement and bias among the various threshold velocities. RESULTS Mean velocity did not differ significantly among the thresholds evaluated. There was a strong positive correlation between the LTv velocity and the velocity for GTv (r = 0.91), LTp (r = 0.96), GTp (r = 0.94), and HRdp (r = 0.95). CONCLUSIONS AND CLINICAL RELEVANCE Results indicated that LTv could be determined for dogs undergoing intense exercise on a treadmill, and the treadmill velocity corresponding to the LTv was associated with the velocity for the other hallmarks of endurance. Thus, that method may be useful for prescription and evaluation of conditioning programs for dogs.
Mostrar más [+] Menos [-]Measurements of the radiographic cardiac silhouette of ospreys (Pandion haliaetus) Texto completo
2019
Woo, Krystal M. T. | Barron, Grace H. | Daugherty, Allison L. | Woo, Jennifer M. P. | Kehoe, Spencer P. | Aguilar, Laura A. B. | Cavanaugh, Sarah M.
OBJECTIVE To evaluate and report measurements of the radiographic cardiac silhouette of healthy juvenile and adult ospreys (Pandion haliaetus). ANIMALS 54 ospreys (22 adults, 19 juveniles, and 13 birds of undetermined age) without clinical signs of cardiac disease and with adequate ventrodorsal radiographic images for cardiac silhouette assessment. PROCEDURES Radiographs of ospreys were assessed to determine cardiac width at the widest point as well as sternal width and thoracic width at the same level. Two-way mixed-effects models were used to evaluate interrater reliability for mean rating. Multivariable linear regression analysis was used to create predictive models of cardiac width and to establish a theoretical reference range for healthy ospreys. RESULTS Cardiac width of healthy ospreys was approximately 90% to 92% of sternal width and 67% to 69% of thoracic width. Both sternal width and thoracic width were significant predictors of cardiac width in independent predictive models as well as in a combined model after controlling for age. Thirty-four of 41 (83%) measured cardiac widths were within the theoretical reference range. CONCLUSIONS AND CLINICAL RELEVANCE Ospreys are sentinels used in monitoring environmental health. Environmental factors may have an impact on the cardiac health of ospreys, but reference values for healthy ospreys have not been established for use in assessing cardiomegaly in this species. The radiographic ratios and predictive model obtained in this study may be useful for objective evaluation of cardiomegaly in ospreys.
Mostrar más [+] Menos [-]Effect of vaccination of pregnant beef heifers on the concentrations of serum IgG and specific antibodies to bovine herpesvirus 1, bovine viral diarrhea virus 1, and bovine viral diarrhea virus 2 in heifers and calves Texto completo
2019
Reppert, E. J. | Chamorro, M. F. | Robinson, L. | Cernicchiaro, N. | Wick, J. | Weaber, R. L. | Haines, D. M.
The objective of this study was to evaluate the effect of late-gestation vaccination of beef heifers with 2 doses of a killed-virus (KV) vaccine containing bovine herpesvirus 1 (BoHV-1), bovine viral diarrhea virus 1 (BVDV-1), and bovine viral diarrhea virus 2 (BVDV-2) on the serum concentrations of antibody against BoHV-1, BVDV-1, and BVDV-2 in heifers and their calves and on the IgG concentration in the calves. Of the 47 pregnant beef heifers selected, 26 received 2 doses of the vaccine at 6.5 to 8 mo of gestation (at pregnancy check), and 21 received 2 doses of saline. The mean log2 serum titers of neutralizing antibody against BoHV-1, BVDV-1, and BVDV-2 before vaccination did not differ significantly between the treatment groups; however, at calving all 3 mean titers were significantly greater (P < 0.05) in the vaccinated heifers than in the control heifers. At 24 h after birth the mean serum IgG levels in the calves did not differ significantly between the 2 groups, at 30.18 and 32.28 g/L, respectively (P < 0.05); however, the mean log2 serum titers of antibody to all 3 viruses were greater in the calves nursing colostrum from the vaccinated heifers than in the calves nursing colostrum from the nonvaccinated heifers and significantly so for BoHV-1 and BVDV-1 (P < 0.001 and P = 0.009, respectively). Thus, late-gestation vaccination of beef heifers could result in a greater and more consistent deposition of specific antibodies in colostrum, reducing the variability of initial titers in calves and increasing the duration of maternal immunity.
Mostrar más [+] Menos [-]Effect of passive transfer of immunity on growth performance of preweaned dairy calves Texto completo
2019
Elsohaby, I. | Cameron, M. | Elmoslemany, A. | McClure, J. T. | Keefe, G.
The primary objective of this observational study was to examine the association between passive transfer of immunity and growth performance in preweaning calves. A secondary objective was to evaluate the utility of a heart girth tape (HGT) to estimate body weight (BW) in preweaning calves. A total of 142 Holstein calves were enrolled in this study. Blood samples were collected 24 to 48 hours after birth and serum immunoglobulin G (IgG) concentration for each calf was measured by radial immunodiffusion assay. Calf BW was determined at birth, at 21 days, and at weaning using an electronic scale (ES) and HGT. A significant positive association was detected between serum IgG and both BW at 21 days and average daily gain (ADG) from 0 to 21 days of life. Additionally, ADG from 0 to 42 days of life showed a trend toward an improved rate of gain as IgG concentration increased. The Pearson correlation coefficient between BW obtained from ES and HGT was 0.81 at birth, 0.86 at 21 days, and 0.83 at weaning. The mean differences between BW obtained from ES and HGT were -3.1 kg at birth, -3.2 kg at 21 days, and -7.7 kg at weaning. In conclusion, serum IgG concentration in neonatal calves is an important contributing factor for the variation in growth performance of preweaning calves. The HGT can be used to estimate the BW of preweaning calves but has a tendency to overestimate weight, especially at weaning compared to birth and 21 days of age.
Mostrar más [+] Menos [-]